Bridge Statistics for Allouez, Wisconsin (WI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 82ft / 24.7mTotal length
  • 296,400Total average daily traffic
  • 3,865Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Allouez
  • No street view available for this location

New bridges in Allouez, WI - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11970-1979
  • 81980-1989
  • 12010-2019
Average Bridge Daily Traffic in Allouez, WI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 20.0%Very good
  • 20.0%Good
  • 60.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 80.0%Very good
  • 20.0%Good
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 20.0%Very good
  • 20.0%Good
  • 60.0%Satisfactory
Find on map >>   Show street view

Structure Number: B050172,  Location: 0.9M E JCT STH 57 (Lat: 44.467089,  Lng: -88.023792),  Route carried "on" structure: State highway 172,  Year Built: 1984,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 42,350 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 84,000 (year 2039),  Design Load: HS 20,  Features Intersected: LRD LIBAL STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 75.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B050173,  Location: 0.6M W JCT CTH XX (Lat: 44.464558,  Lng: -88.015756),  Route carried "on" structure: State highway 172,  Year Built: 1984,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 42,350 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 84,000 (year 2039),  Design Load: HS 20,  Features Intersected: LRD EAST RIVER DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.2m (69.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 63.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B050174,  Location: 1.3M E JCT STH 57 (Lat: 44.464486,  Lng: -88.016622),  Route carried "on" structure: State highway 172,  Year Built: 1984,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 42,350 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 84,000 (year 2039),  Design Load: HS 20,  Features Intersected: LRD EAST RIVER DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.1m (72.5ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 67.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B050176,  Location: 1.7M E JCT STH 57 (Lat: 44.462264,  Lng: -88.010725),  Route carried "on" structure: State highway 172,  Year Built: 1982,  Status: Open,  Structure Length: 10.63m (34.88ft),  Average Daily Traffic: 42,350 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 84,000 (year 2039),  Design Load: HS 20,  Features Intersected: EAST RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.4m (86.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 68.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B050411,  Location: 1.6 M N JCT STH 172 (Lat: 44.491472,  Lng: -88.016889),  Route carried "on" structure: County highway ,  Year Built: 2016,  Status: Open,  Structure Length: 2.98m (9.78ft),  Average Daily Traffic: 14,700 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 15,300 (year 2036),  Design Load: HL 93,  Features Intersected: WISCONSIN CENTRAL LTD RR,  Facility Carried by Structure: CTH X, S. WEBSTER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.7m (94.2ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: B05015,  Location: 0.4M E JCT STH 57 (Lat: 44.470283,  Lng: -88.031431),  Route carried "under" structure: State highway 172,  Year Built: 1975,  Structure Length: 0. m,  Average Daily Traffic: 84,700 (year 2020),  Truck Traffic: 1%,  Features Intersected: STH 172,  Facility Carried by Structure: CTH X WEBSTER ST
Minimum Vertical Clearance: 4.83m (15.85ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.9m (101.4ft)

Find on map >>   Show street view

Structure Number: B050171,  Location: 0.5M N JCT CTH XX (Lat: 44.466667,  Lng: -88.023333),  Route carried "under" structure: City street ,  Year Built: 1984,  Structure Length: 0. m,  Average Daily Traffic: 5,100 (year 2020),  Features Intersected: LRD LIBAL STREET,  Facility Carried by Structure: STH 172 WB
Minimum Vertical Clearance: 4.58m (15.03ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: B050172,  Location: 0.5M N JCT CTH XX (Lat: 44.467089,  Lng: -88.023792),  Route carried "under" structure: City street ,  Year Built: 1984,  Structure Length: 0. m,  Average Daily Traffic: 5,100 (year 2020),  Features Intersected: LRD LIBAL STREET,  Facility Carried by Structure: STH 172 EB
Minimum Vertical Clearance: 4.71m (15.45ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: B050173,  Location: 0.6M N JCT CTH XX (Lat: 44.464558,  Lng: -88.015756),  Route carried "under" structure: City street ,  Year Built: 1984,  Structure Length: 0. m,  Average Daily Traffic: 1,300 (year 2020),  Features Intersected: LRD EAST RIVER DRIVE,  Facility Carried by Structure: STH 172 WB
Minimum Vertical Clearance: 4.51m (14.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.2m (69.6ft)

Find on map >>   Show street view

Structure Number: B050174,  Location: 0.6M N JCT CTH XX (Lat: 44.464486,  Lng: -88.016622),  Route carried "under" structure: City street ,  Year Built: 1984,  Structure Length: 0. m,  Average Daily Traffic: 1,300 (year 2020),  Features Intersected: LRD EAST RIVER DRIVE,  Facility Carried by Structure: STH 172 EB
Minimum Vertical Clearance: 4.46m (14.63ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.1m (72.5ft)

Find on map >>   Show street view

Structure Number: B050722,  Location: 1.5M N JCT STH 172 TO W (Lat: 44.493333,  Lng: -88.021667),  Route carried "under" structure: State highway 57,  Year Built: 1905,  Structure Length: 0. m,  Average Daily Traffic: 14,800 (year 2019),  Truck Traffic: 3%,  Features Intersected: STH 57-RIVERSIDE DR,  Facility Carried by Structure: CNW RR
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 24.1m (79.1ft)