  • National Bridge Inventory (NBI) Statistics
  • 28Number of bridges
  • 666ft / 203mTotal length
  • 259,998Total average daily traffic
  • 17,460Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Augusta
  • No street view available for this location

New bridges in Augusta, ME - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 21930-1939
  • 11940-1949
  • 101950-1959
  • 11970-1979
  • 21990-1999
  • 52000-2009
  • 12010-2019
Reconstructed bridges in Augusta, ME - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 51990-1999
  • 32000-2009
  • 22010-2019
Average Bridge Daily Traffic in Augusta, ME
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 26.3%Very good
  • 15.8%Good
  • 31.6%Satisfactory
  • 21.1%Fair
  • 5.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 15.8%Very good
  • 26.3%Good
  • 47.4%Satisfactory
  • 10.5%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 21.1%Very good
  • 21.1%Good
  • 42.1%Satisfactory
  • 10.5%Fair
  • 5.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 13.3%Excellent
  • 13.3%Very good
  • 13.3%Good
  • 46.7%Satisfactory
  • 13.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 25.0%Satisfactory
  • 25.0%Fair
Find on map >>   Show street view

Location: 0.5 MI NE RT 201,100 (Lat: 41.001228,  Lng: -100.835261),  Route carried "under" structure: County highway 81500,  Year Built: 1010,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 2,000 (year 0015),  Truck Traffic: 5%,  Average Future Daily Traffic: 254 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: 02100RIGGS BROOK,  Facility Carried by Structure: BLAIR ROAD
Lanes on structure: 91,  Lanes under structure: 96,  Toll: Toll bridge,  Owner: Indian Tribal Government,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 201.60m (661.42ft),  Skew: 90 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 59.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1465,  Location: MILE 105.8 ON I-95 S B (Lat: 44.346211,  Lng: -69.794611),  Route carried "on" structure: State highway 95,  Year Built: 1959,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 4.29m (14.07ft),  Average Daily Traffic: 13,970 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,558 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: ROUTESS 8,11,&27
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 309.833,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1466,  Location: 1.5 MI N US #202 (Lat: 44.338069,  Lng: -69.807611),  Route carried "on" structure: State highway 95,  Year Built: 1959,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 12.65m (41.50ft),  Average Daily Traffic: 18,790 (year 2016),  Truck Traffic: 10%,  Average Future Daily Traffic: 26,306 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: MARTIN STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 311.184,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2082,  Location: 1.0 MI NW OF JCT RTE 27 (Lat: 44.338811,  Lng: -69.808269),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 1.23m (4.04ft),  Average Daily Traffic: 2,368 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,315 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: BOND BROOK,  Facility Carried by Structure: BOND BROOK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.706,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 2083,  Location: 1.1 MI NW OF JCT RTE 27 (Lat: 44.339389,  Lng: -69.808761),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 2,368 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,315 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: BOND BROOK,  Facility Carried by Structure: BOND BROOK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.786,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.8m (15.7ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 76.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 2385,  Location: 3.7 MI NW OF PRINCETON TL (Lat: 45.265039,  Lng: -67.629561),  Route carried "on" structure: State highway 1,  Year Built: 2007,  Status: Open,  Structure Length: 0.95m (3.12ft),  Average Daily Traffic: 1,641 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,462 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: HUNTLEY BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 543.831,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.6m (28.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 2719,  Location: 3.2 MI SO TOWNLINE (Lat: 44.337981,  Lng: -69.757311),  Route carried "on" structure: State highway 201,  Year Built: 2010,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 9,253 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 12,954 (year 2036),  Design Load: HL 93,  Features Intersected: RIGGS BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 53.897,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.3m (20.7ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 64.8 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 3077,  Location: 0.3 MI N OF BRIDGE STREET (Lat: 44.322850,  Lng: -69.775169),  Route carried "on" structure: State highway 8,  Year Built: 1934,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 13,526 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 18,936 (year 2036),  Design Load: HS 20,  Features Intersected: BOND BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.207,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 3078,  Location: 0.2 MI E OF RTE US 201 (Lat: 44.316769,  Lng: -69.772161),  Route carried "on" structure: State highway ,  Year Built: 1972,  Status: Open,  Structure Length: 12.98m (42.59ft),  Average Daily Traffic: 13,867 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,414 (year 2036),  Design Load: HS 20,  Features Intersected: KENNEBEC RIVER,  Facility Carried by Structure: CONY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.306,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Navigation Control: Yes ( Vertical Clearance: 8.2m (26.9ft), Horizontal Clearance: 25.9m (85.0ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 28.0m (91.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 26.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: August 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 3528,  Location: 0.1MI N JCT GROVE ST (Lat: 44.312911,  Lng: -69.775181),  Route carried "on" structure: County highway ,  Year Built: 1939,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 5,152 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,213 (year 2036),  Design Load: HS 20,  Features Intersected: Old MCRR (now side road),  Facility Carried by Structure: WATER STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.885,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 2.2m (7.2ft),  Right: 2.2m (7.2ft),  Curb-To-Curb Width: 12.9m (42.3ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Poor,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5196,  Location: .2 MI W 9 (Lat: 44.312450,  Lng: -69.772861),  Route carried "on" structure: State highway 201,  Year Built: 1949,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 63.95m (209.81ft),  Average Daily Traffic: 22,749 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 31,849 (year 2036),  Design Load: HS 20,  Features Intersected: KENNEBEC RIVER + MCRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 50.710,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Navigation Control: Yes ( Vertical Clearance: 21.3m (69.9ft), Horizontal Clearance: 20.4m (66.9ft)),  Material/Design: Steel continuous,  Design/Construction: Truss - Deck,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 6,  Length of Maximum Span: 106.7m (350.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Other Special Inspection Frequency: Every 60 months,  Inspection Date: December 2021,  Critical Feature Inspection Date: October 2021,  Underwater Inspection Date: August 2019,  Other Special Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 5747,  Location: 1.3 MI S JCT 8-11-27 (Lat: 44.339331,  Lng: -69.811031),  Route carried "on" structure: County highway ,  Year Built: 1959,  Year Reconstructed: 1980,  Status: Open,  Structure Length: 1.08m (3.54ft),  Average Daily Traffic: 7,465 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,451 (year 2036),  Design Load: H 20,  Features Intersected: BOND BROOK,  Facility Carried by Structure: LEIGHTON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.237,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.7m (31.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.6m (34.8ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 5787,  Location: 1.5 MI N US 202 OVERPASS (Lat: 44.337950,  Lng: -69.807469),  Route carried "on" structure: State highway 95,  Year Built: 1959,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 12.56m (41.21ft),  Average Daily Traffic: 18,290 (year 2016),  Truck Traffic: 10%,  Average Future Daily Traffic: 25,606 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: BOND BROOK & BOND BK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 176.609,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5788,  Location: OVER I95 0.2 MI N US 202 (Lat: 44.320131,  Lng: -69.813431),  Route carried "on" structure: County highway ,  Year Built: 1958,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 7.42m (24.34ft),  Average Daily Traffic: 3,330 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,662 (year 2036),  Design Load: H 20,  Features Intersected: INTERSTATE 95,  Facility Carried by Structure: OLD WINTHROP ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.127,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 34.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 5793,  Location: I-95 INTERCHANGE 112 (Lat: 44.346019,  Lng: -69.794550),  Route carried "on" structure: State highway 95,  Year Built: 1959,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 4.22m (13.85ft),  Average Daily Traffic: 15,720 (year 2016),  Truck Traffic: 10%,  Average Future Daily Traffic: 22,008 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: ROUTES 8,11,&27
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 177.977,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 56.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 5806,  Location: 1.0 MI N OF JCT RTE 104 (Lat: 44.351469,  Lng: -69.784539),  Route carried "on" structure: County highway ,  Year Built: 1959,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 9.27m (30.41ft),  Average Daily Traffic: 2,652 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,713 (year 2036),  Design Load: H 20,  Features Intersected: INTERSTATE 95,  Facility Carried by Structure: OLD BELGRADE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 5807,  Location: OVER I-95 MILE 103.1 NB (Lat: 44.312950,  Lng: -69.809850),  Route carried "on" structure: Ramp State highway ,  Year Built: 1959,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 6.31m (20.70ft),  Average Daily Traffic: 4,660 (year 2016),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,524 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: INTERSTATE 95,  Facility Carried by Structure: RAMP TO & FROM I95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.145,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Other
Find on map >>   Show street view

Structure Number: 5808,  Location: 1.6 MI W OF JCT RTE 201 (Lat: 44.316439,  Lng: -69.811550),  Route carried "on" structure: State highway 202,  Year Built: 1955,  Status: Open,  Structure Length: 8.02m (26.31ft),  Average Daily Traffic: 16,934 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 23,708 (year 2036),  Design Load: HS 20,  Features Intersected: INTERSTATE 95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 163.847,  Lanes on structure: 5,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 22 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 27.6m (90.6ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5809,  Location: 0.1 MI E OF I 95 OVERPASS (Lat: 44.316231,  Lng: -69.808631),  Route carried "on" structure: Ramp State highway ,  Year Built: 1950,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 5.66m (18.57ft),  Average Daily Traffic: 4,820 (year 2016),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,748 (year 2036),  Design Load: HS 20,  Features Intersected: ROUTES 11 17 100 202,  Facility Carried by Structure: RAMP TO & FROM I 9
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.612,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.1m (88.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 64,  Location: .2 Mi.W RTE 201/100 (Lat: 44.335361,  Lng: -69.764581),  Route carried "on" structure: State highway 3,  Year Built: 2005,  Status: Open,  Structure Length: 33.78m (110.83ft),  Average Daily Traffic: 14,820 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 20,748 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: Kennebec River
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.587,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.2m (63.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 73.0m (239.5ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 6406,  Location: INTERCHANGE 113 (Lat: 44.354269,  Lng: -69.781631),  Route carried "on" structure: State highway 3,  Year Built: 2005,  Status: Open,  Structure Length: 5.06m (16.60ft),  Average Daily Traffic: 4,867 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,814 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: I-95 NORTHBOUND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.835,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 35 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 50.6m (166.0ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 49.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 6407,  Location: INTERCHANGE 113 (Lat: 44.354869,  Lng: -69.782219),  Route carried "on" structure: State highway 3,  Year Built: 2005,  Status: Open,  Structure Length: 4.53m (14.86ft),  Average Daily Traffic: 4,867 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,814 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: I-95 SOUTHBOUND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.835,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.4m (145.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 6408,  Location: 0.3 MI E I95 INTERCH 113 (Lat: 44.351731,  Lng: -69.778089),  Route carried "on" structure: State highway 3,  Year Built: 2005,  Status: Open,  Structure Length: 3.63m (11.91ft),  Average Daily Traffic: 17,211 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 24,095 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: EIGHT ROD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.688,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.2m (63.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.4m (116.1ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Location: JCT OF RTE'S 1& 3 (Lat: 44.423653,  Lng: -69.806822),  Route carried "on" structure: Ramp State highway 82310,  Structure Length: 0. m,  Average Daily Traffic: 10,635 (year 2014),  Truck Traffic: 5%,  Features Intersected: US ROUE 1,  Facility Carried by Structure: ROUTE 3
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 74.207,  Lanes on structure: 4,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Location: 2.2 MI. NE TOWNLINE (Lat: 44.299475,  Lng: -69.716731),  Route carried "under" structure: Alternate City street 12310,  Structure Length: 0. m,  Average Daily Traffic: 10,416 (year 2014),  Truck Traffic: 9%,  Features Intersected: RTE 11, 100, US202,  Facility Carried by Structure: MCRR & RAMPS TO 41
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 149.476,  Lanes on structure: 2,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Location: INTERCHANGE 113 (Lat: 44.354258,  Lng: -69.781644),  Route carried "under" structure: County highway 62310,  Structure Length: 0. m,  Average Daily Traffic: 12,597 (year 2014),  Truck Traffic: 11%,  Features Intersected: ROUTE 3,  Facility Carried by Structure: I-95 NORTHBOUND
Minimum Vertical Clearance: 5.64m (18.50ft),  Kilometerpoint: 179.345,  Lanes on structure: 2,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Location: INTERCHANGE 113 (Lat: 44.354839,  Lng: -69.782236),  Route carried "under" structure: County highway 72310,  Structure Length: 0. m,  Average Daily Traffic: 4,570 (year 2014),  Truck Traffic: 9%,  Features Intersected: ROUTE 3,  Facility Carried by Structure: I-95 SOUTHBOUND
Minimum Vertical Clearance: 5.64m (18.50ft),  Kilometerpoint: 1.835,  Lanes on structure: 2,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Location: 0.3 MI E I95 INTERCH 113 (Lat: 44.351519,  Lng: -69.777781),  Route carried "under" structure: County highway 82500,  Structure Length: 0. m,  Average Daily Traffic: 460 (year 2014),  Truck Traffic: 5%,  Features Intersected: ROUTE 3,  Facility Carried by Structure: EIGHT ROD ROAD
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 3.766,  Lanes on structure: 2,  Length of Maximum Span: 0.0m