Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Bellflower, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 240ft / 73.4mTotal length
  • 1,761,532Total average daily traffic
  • 185,851Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Bellflower
  • No street view available for this location

New bridges in Bellflower, CA - historical statistics
  • New bridges - historical statistics
  • 21950-1959
  • 161960-1969
Reconstructed bridges in Bellflower, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 01980-1989
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Bellflower, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 50.0%Good
  • 16.7%Satisfactory
  • 33.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 91.7%Good
  • 8.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 66.7%Excellent
  • 33.3%Very good
Find on map >>   Show street view

Structure Number: 53 1257,  Location: 07-LA-091-R16.54-BFL (Lat: 33.876608,  Lng: -118.108889),  Route carried "on" structure: State highway 91,  Year Built: 1968,  Status: Open,  Structure Length: 6.25m (20.51ft),  Average Daily Traffic: 242,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 258,112 (year 2038),  Design Load: HS 20,  Features Intersected: UP RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.540,  Lanes on structure: 13,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 55.1m (180.8ft),  Skew: 36 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 55.1m (180.8ft),  Out-to-Out Width: 56.7m (186.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1698,  Location: 07-LA-091-R16.62-BFL (Lat: 33.876481,  Lng: -118.108028),  Route carried "on" structure: State highway 91,  Year Built: 1968,  Status: Open,  Structure Length: 8.44m (27.69ft),  Average Daily Traffic: 242,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 258,112 (year 2038),  Design Load: HS 20,  Features Intersected: SAN GABRIEL RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.620,  Lanes on structure: 13,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 52.9m (173.6ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 43.0m (141.1ft),  Curb-To-Curb Width: 52.9m (173.6ft),  Out-to-Out Width: 54.3m (178.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Length Of Structure Improvement: 8.44m (27.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 171,  Location: 07-LA-605-R3.40-CRTS (Lat: 33.853258,  Lng: -118.095328),  Route carried "on" structure: City street Q827,  Year Built: 1964,  Status: Open,  Structure Length: 6.95m (22.80ft),  Average Daily Traffic: 2,100 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,885 (year 2037),  Design Load: HS 20,  Features Intersected: INTERSTATE 605,  Facility Carried by Structure: 195TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 8.6m (28.2ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1718,  Location: 07-LA-091-R15.61-BFL (Lat: 33.876000,  Lng: -118.125456),  Route carried "on" structure: State highway 91,  Year Built: 1968,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 242,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 258,112 (year 2038),  Design Load: HS 20,  Features Intersected: BELLFLOWER BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.610,  Lanes on structure: 11,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 43.7m (143.4ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 26.0m (85.3ft),  Curb-To-Curb Width: 43.7m (143.4ft),  Out-to-Out Width: 45.1m (148.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 37.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 24.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1719,  Location: 07-LA-091-R15.87-BFL (Lat: 33.875972,  Lng: -118.121061),  Route carried "on" structure: State highway 91,  Year Built: 1968,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 3.38m (11.09ft),  Average Daily Traffic: 242,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 258,112 (year 2038),  Design Load: HS 20,  Features Intersected: BIXBY AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.870,  Lanes on structure: 12,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 51.9m (170.3ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 18.7m (61.4ft),  Curb-To-Curb Width: 51.9m (170.3ft),  Out-to-Out Width: 53.7m (176.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 29.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 20.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 175,  Location: 07-LA-134-R7.26-GNDL (Lat: 34.156700,  Lng: -118.252792),  Route carried "on" structure: City street Q410,  Year Built: 1968,  Status: Open,  Structure Length: 7.00m (22.97ft),  Average Daily Traffic: 7,800 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 8,200 (year 2040),  Design Load: HS 20,  Features Intersected: STATE ROUTE 134 & RAMPS,  Facility Carried by Structure: LOUISE ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 12,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.4m (119.4ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1757,  Location: 07-LA-091-R15.39-BFL (Lat: 33.875933,  Lng: -118.129244),  Route carried "on" structure: State highway 91,  Year Built: 1968,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 242,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 258,112 (year 2038),  Design Load: HS 20,  Features Intersected: ARDMORE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.390,  Lanes on structure: 13,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 53.1m (174.2ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 15.6m (51.2ft),  Curb-To-Curb Width: 53.1m (174.2ft),  Out-to-Out Width: 54.9m (180.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1759,  Location: 07-LA-091-R15.10-BFL (Lat: 33.876936,  Lng: -118.134142),  Route carried "on" structure: State highway 91,  Year Built: 1968,  Status: Open,  Structure Length: 4.15m (13.62ft),  Average Daily Traffic: 286,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 310,000 (year 2041),  Design Load: HS 20,  Features Intersected: CLARK AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.100,  Lanes on structure: 11,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 43.7m (143.4ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 43.7m (143.4ft),  Out-to-Out Width: 45.1m (148.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1760F,  Location: 07-LA-019-6.03-BFL (Lat: 33.876800,  Lng: -118.142906),  Route carried "on" structure: Ramp State highway 19,  Year Built: 1968,  Status: Open,  Structure Length: 5.42m (17.78ft),  Average Daily Traffic: 8,000 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,304 (year 2041),  Design Load: HS 20,  Features Intersected: ST RTE 19 (LAKEWOOD BL)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.030,  Lanes on structure: 1,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.0m,  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1760G,  Location: 07-LA-019-6.07-BFL (Lat: 33.877414,  Lng: -118.142911),  Route carried "on" structure: Ramp State highway 19,  Year Built: 1968,  Status: Open,  Structure Length: 5.42m (17.78ft),  Average Daily Traffic: 8,000 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,304 (year 2041),  Design Load: HS 20,  Features Intersected: ST RTE 19 (LAKEWOOD BL)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.070,  Lanes on structure: 1,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C0079,  Location: 0.3MI W/O I-605 FWY (Lat: 33.901992,  Lng: -118.109142),  Route carried "on" structure: City street L079,  Year Built: 1951,  Status: Open,  Structure Length: 9.28m (30.45ft),  Average Daily Traffic: 28,840 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 34,608 (year 2040),  Design Load: HS 20,  Features Intersected: SAN GABRIEL RIV,  Facility Carried by Structure: ROSECRANS AVE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 14.7m (48.2ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Excellent,  Operating Rating: 28.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C0083,  Location: 0.3MI W/O I-605 FWY (Lat: 33.887714,  Lng: -118.108872),  Route carried "on" structure: City street L086,  Year Built: 1952,  Year Reconstructed: 1972,  Status: Open,  Structure Length: 9.69m (31.79ft),  Average Daily Traffic: 27,192 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 32,630 (year 2040),  Design Load: HS 20,  Features Intersected: SAN GABRIEL RIV,  Facility Carried by Structure: ALONDRA BLVD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.1m (69.2ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 21.1m (69.2ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 78.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1718,  Location: 07-LA-091-R15.61-BFL (Lat: 33.876000,  Lng: -118.125456),  Route carried "under" structure: City street ,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 35,200 (year 2015),  Truck Traffic: 2%,  Features Intersected: BELLFLOWER BLVD,  Facility Carried by Structure: STATE ROUTE 91
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 0.000,  Lanes on structure: 11,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.0m (85.3ft)

Find on map >>   Show street view

Structure Number: 53 172,  Location: 07-LA-091-R16.07-BFL (Lat: 33.876047,  Lng: -118.117533),  Route carried "under" structure: City street ,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 25,400 (year 2019),  Truck Traffic: 2%,  Features Intersected: WOODRUFF AVE,  Facility Carried by Structure: STATE ROUTE 91
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 12,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.1m (85.6ft)

Find on map >>   Show street view

Structure Number: 53 1759,  Location: 07-LA-091-R15.10-BFL (Lat: 33.876936,  Lng: -118.134142),  Route carried "under" structure: City street ,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2020),  Truck Traffic: 1%,  Features Intersected: CLARK AVE,  Facility Carried by Structure: STATE ROUTE 91
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 11,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 53 176,  Location: 07-LA-091-R6.03-BFL (Lat: 33.876939,  Lng: -118.142908),  Route carried "under" structure: State highway 19,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 43,000 (year 2015),  Truck Traffic: 4%,  Features Intersected: ST RTE 19 (LAKEWOOD BL),  Facility Carried by Structure: STATE ROUTE 91
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 6.050,  Lanes on structure: 10,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Find on map >>   Show street view

Structure Number: 53 1760F,  Location: 07-LA-019-6.03-BFL (Lat: 33.876800,  Lng: -118.142906),  Route carried "under" structure: State highway 19,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 36,000 (year 2015),  Truck Traffic: 2%,  Features Intersected: ST RTE 19 (LAKEWOOD BL)
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 6.030,  Lanes on structure: 1,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.9m (62.0ft)

Find on map >>   Show street view

Structure Number: 53 1760G,  Location: 07-LA-019-6.07-BFL (Lat: 33.877414,  Lng: -118.142911),  Route carried "under" structure: State highway 19,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 36,000 (year 2015),  Truck Traffic: 2%,  Features Intersected: ST RTE 19 (LAKEWOOD BL)
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 6.070,  Lanes on structure: 1,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.9m (62.0ft)

Discuss Bellflower, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.