Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Buena Vista, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 22Number of bridges
  • 256ft / 78.5mTotal length
  • 654,504Total average daily traffic
  • 59,266Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Buena Vista
  • No street view available for this location

New bridges in Buena Vista, MI - historical statistics
  • New bridges - historical statistics
  • 11950-1959
  • 31960-1969
  • 81970-1979
  • 22000-2009
  • 42010-2019
  • 42020-2022
Reconstructed bridges in Buena Vista, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 11970-1979
  • 01980-1989
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Buena Vista, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 15.4%Excellent
  • 15.4%Very good
  • 15.4%Good
  • 38.5%Satisfactory
  • 15.4%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.1%Excellent
  • 23.1%Very good
  • 30.8%Good
  • 15.4%Satisfactory
  • 7.7%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 23.1%Excellent
  • 7.7%Very good
  • 15.4%Good
  • 46.2%Satisfactory
  • 7.7%Fair
Find on map >>   Show street view

Structure Number: 9124,  Location: @ I-75 (Lat: 43.429014,  Lng: -83.889583),  Route carried "on" structure: County highway ,  Year Built: 1971,  Status: Open,  Structure Length: 3.34m (10.96ft),  Average Daily Traffic: 1,409 (year 1994),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,040 (year 1977),  Design Load: H 15,  Features Intersected: I-675 RAMP,  Facility Carried by Structure: JANES RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.188,  Lanes on structure: 2,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.3m (43.6ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Operating Rating: 56.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: October 2020,  Other Special Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 9125,  Location: @ S JCT I-75 (Lat: 43.433628,  Lng: -83.890658),  Route carried "on" structure: Interstate 675,  Year Built: 1971,  Status: Open,  Structure Length: 8.23m (27.00ft),  Average Daily Traffic: 10,300 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 20,630 (year 2027),  Design Load: HS 20,  Features Intersected: I-75
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes (Inventory Route: 46,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.0m (98.4ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 79.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 9126,  Location: 0.1 MI W OF I-75 (Lat: 43.433639,  Lng: -83.896386),  Route carried "on" structure: County highway 2004,  Year Built: 1971,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 8.63m (28.31ft),  Average Daily Traffic: 10,489 (year 1994),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,250 (year 1977),  Design Load: H 15,  Features Intersected: I-675,  Facility Carried by Structure: OUTER DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.564,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 46,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 24.3m (79.7ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 74.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 9151,  Location: @ N JCT I-75 (Lat: 43.431242,  Lng: -83.890647),  Route carried "on" structure: Ramp Interstate 675,  Year Built: 1971,  Status: Open,  Structure Length: 11.55m (37.89ft),  Average Daily Traffic: 1,290 (year 1982),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,290 (year 2002),  Design Load: HS 20,  Features Intersected: I-675 & I-75
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.838,  Lanes on structure: 1,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 26.7m (87.6ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 67.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 9156,  Location: 0.5 MI S OF M-81 (Lat: 43.443236,  Lng: -83.890675),  Route carried "on" structure: Interstate 75,  Year Built: 1961,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 4.17m (13.68ft),  Average Daily Traffic: 47,480 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 57,597 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: CSX RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 27.621,  Lanes on structure: 6,  Base Highway Network: Yes (Inventory Route: 46,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 37.8m (124.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 38.1m (125.0ft),  Out-to-Out Width: 40.2m (131.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Fair,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9157,  Location: 1.0 MI S OF M-13 (Lat: 43.467714,  Lng: -83.893542),  Route carried "on" structure: Interstate 75,  Year Built: 1958,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 4.07m (13.35ft),  Average Daily Traffic: 46,000 (year 2009),  Truck Traffic: 10%,  Average Future Daily Traffic: 51,849 (year 2032),  Design Load: HS 20,  Features Intersected: CSX RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 30.387,  Lanes on structure: 6,  Base Highway Network: Yes (Inventory Route: 46,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 37.8m (124.0ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 37.8m (124.0ft),  Out-to-Out Width: 39.4m (129.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 916,  Location: 0.8 MI S OF M-46 (Lat: 43.401158,  Lng: -83.890992),  Route carried "on" structure: County highway 2004,  Year Built: 2015,  Status: Open,  Structure Length: 5.98m (19.62ft),  Average Daily Traffic: 4,080 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,800 (year 2035),  Design Load: Greater than HL93,  Features Intersected: I-75,  Facility Carried by Structure: HESS RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.016,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.4m (96.5ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9161,  Location: @ M-46 (Lat: 43.414678,  Lng: -83.890800),  Route carried "on" structure: State highway 46,  Year Built: 2021,  Status: Open,  Structure Length: 6.17m (20.24ft),  Average Daily Traffic: 16,800 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 18,550 (year 2040),  Design Load: Greater than HL93,  Features Intersected: I-75
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.418,  Lanes on structure: 4,  Lanes under structure: 10,  Base Highway Network: Yes (Inventory Route: 373,  Subroute: 53),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.8m (101.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9162,  Location: 1.0 MI N OF M-46 & I-75 B (Lat: 43.429019,  Lng: -83.890639),  Route carried "on" structure: County highway ,  Year Built: 2012,  Status: Open,  Structure Length: 5.85m (19.19ft),  Average Daily Traffic: 1,000 (year 2012),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,200 (year 2032),  Design Load: Greater than HL93,  Features Intersected: I-75,  Facility Carried by Structure: JANES RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.102,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.5m (106.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9163,  Location: 1.0 MI S OF M-81 (Lat: 43.436236,  Lng: -83.890656),  Route carried "on" structure: County highway ,  Year Built: 1961,  Year Reconstructed: 1971,  Status: Posted for load,  Structure Length: 7.15m (23.46ft),  Average Daily Traffic: 360 (year 2012),  Truck Traffic: 5%,  Average Future Daily Traffic: 450 (year 2032),  Design Load: H 15,  Features Intersected: I-75,  Facility Carried by Structure: WADSWORTH RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.018,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Poor,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 37.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: November 2020,  Other Special Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 9164,  Location: @ M-81 (Lat: 43.450625,  Lng: -83.890672),  Route carried "on" structure: State highway 81,  Year Built: 2006,  Status: Open,  Structure Length: 5.93m (19.46ft),  Average Daily Traffic: 16,400 (year 2005),  Truck Traffic: 8%,  Average Future Daily Traffic: 29,620 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: I-75
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.088,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 47,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.2m (95.8ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.6m (51.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 82.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 14325,  Location: 0.3 MI S OF M-46 (Lat: 43.409408,  Lng: -83.890872),  Route carried "on" structure: Interstate 75,  Year Built: 2021,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 32,900 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 36,375 (year 2040),  Design Load: Greater than HL93,  Features Intersected: CSX RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 23.861,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 46,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 21.5m (70.5ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 21.4m (70.2ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 20 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 14326,  Location: 0.3 MI S OF M-46 (Lat: 43.409447,  Lng: -83.891144),  Route carried "on" structure: Interstate 75,  Year Built: 2021,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 32,900 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 36,375 (year 2040),  Design Load: Greater than HL93,  Features Intersected: CSX RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 23.860,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 46,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 21.5m (70.5ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 21.4m (70.2ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 20 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9124,  Location: @ I-75 (Lat: 43.429014,  Lng: -83.889583),  Route carried "under" structure: Ramp Interstate 675,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 8,250 (year 1988),  Features Intersected: I-675 RAMP,  Facility Carried by Structure: JANES RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.364,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.3m (43.6ft)

Find on map >>   Show street view

Structure Number: 9125,  Location: @ S JCT I-75 (Lat: 43.433628,  Lng: -83.890658),  Route carried "under" structure: Interstate 75,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 47,480 (year 2007),  Truck Traffic: 12%,  Features Intersected: I-75
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 26.553,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.0m (98.4ft)

Find on map >>   Show street view

Structure Number: 9126,  Location: 0.1 MI W OF I-75 (Lat: 43.433639,  Lng: -83.896386),  Route carried "under" structure: Interstate 675,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 18,738 (year 2017),  Truck Traffic: 9%,  Features Intersected: I-675,  Facility Carried by Structure: OUTER DRIVE
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 0.478,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.3m (79.7ft)

Find on map >>   Show street view

Structure Number: 9151,  Location: @ N JCT I-75 (Lat: 43.431242,  Lng: -83.890647),  Route carried "under" structure: Interstate 675,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 69,334 (year 2007),  Truck Traffic: 12%,  Features Intersected: I-675 & I-75
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 26.288,  Lanes on structure: 1,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.7m (87.6ft)

Find on map >>   Show street view

Structure Number: 916,  Location: 0.8 MI S OF M-46 (Lat: 43.401158,  Lng: -83.890992),  Route carried "under" structure: Interstate 75,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 59,200 (year 2013),  Truck Traffic: 7%,  Features Intersected: I-75,  Facility Carried by Structure: HESS RD
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 22.947,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.4m (96.5ft)

Find on map >>   Show street view

Structure Number: 9161,  Location: @ M-46 (Lat: 43.414678,  Lng: -83.890800),  Route carried "under" structure: Interstate 75,  Year Built: 2021,  Structure Length: 0. m,  Average Daily Traffic: 65,800 (year 2020),  Truck Traffic: 7%,  Features Intersected: I-75,  Facility Carried by Structure: M-46
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 24.448,  Lanes on structure: 4,  Lanes under structure: 10,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.8m (101.0ft)

Find on map >>   Show street view

Structure Number: 9162,  Location: 1.0 MI N OF M-46 & I-75 B (Lat: 43.429019,  Lng: -83.890639),  Route carried "under" structure: Interstate 75,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 69,334 (year 2007),  Truck Traffic: 9%,  Features Intersected: I-75,  Facility Carried by Structure: JANES RD
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 26.040,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.5m (106.6ft)

Find on map >>   Show street view

Structure Number: 9163,  Location: 1.0 MI S OF M-81 (Lat: 43.436236,  Lng: -83.890656),  Route carried "under" structure: Interstate 75,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 47,480 (year 2007),  Truck Traffic: 12%,  Features Intersected: I-75,  Facility Carried by Structure: WADSWORTH RD
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 26.842,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 9164,  Location: @ M-81 (Lat: 43.450625,  Lng: -83.890672),  Route carried "under" structure: Interstate 75,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 47,480 (year 2007),  Truck Traffic: 10%,  Features Intersected: I-75,  Facility Carried by Structure: M-81,WASHINGTON ST
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 28.440,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.2m (95.8ft)

Discuss Buena Vista, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.