Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Canton, Missouri (MO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 23Number of bridges
  • 253ft / 76.9mTotal length
  • $898,000Total costs
  • 76,681Total average daily traffic
  • 24,433Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Canton
  • No street view available for this location

New bridges in Canton, MO - historical statistics
  • New bridges - historical statistics
  • 21910-1919
  • 11930-1939
  • 21950-1959
  • 11960-1969
  • 111970-1979
  • 11990-1999
  • 52000-2009
Reconstructed bridges in Canton, MO - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 11990-1999
Average Bridge Daily Traffic in Canton, MO
Average Bridge Truck Traffic in Canton, MO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Very good
  • 16.7%Good
  • 25.0%Satisfactory
  • 33.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 8.3%Excellent
  • 50.0%Good
  • 8.3%Satisfactory
  • 16.7%Fair
  • 16.7%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 8.3%Excellent
  • 25.0%Good
  • 33.3%Satisfactory
  • 25.0%Fair
  • 8.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.1%Very good
  • 71.4%Satisfactory
  • 21.4%Fair
Find on map >>   Show street view

Structure Number: 1648,  Location: S 17 T 62 N R 6 W (Lat: 40.168250,  Lng: -91.586444),  Route carried "on" structure: County highway 122,  Year Built: 1910,  Status: Closed,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 50 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 63 (year 2038),  Features Intersected: WYACONDA RVR,  Facility Carried by Structure: COUNTY RD 429
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.127,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 3.6m (11.8ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Poor,  Channel: Satisfactory,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.32m (1.05ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: January 2018,  Critical Feature Inspection Date: January 2018,  Bridge Improvement Cost: $233,000,  Roadway Improvement Cost: $23,000,  Total Project Cost: $350,000 ( Estimate for 2022),  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 16632,  Location: S 6 T 61 N R 6 W (Lat: 40.120500,  Lng: -91.599472),  Route carried "on" structure: County highway 127,  Year Built: 1910,  Status: Posted for load,  Structure Length: 2.47m (8.10ft),  Average Daily Traffic: 35 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 44 (year 2040),  Features Intersected: SUGAR CR,  Facility Carried by Structure: COUNTY RD 526
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.770,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 3.7m (12.1ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Very good,  Superstructure: Poor,  Substructure: Fair,  Channel: Fair,  Operating Rating: 6.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 6.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of replacement,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.33m (1.08ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Critical Feature Inspection Date: January 2022,  Bridge Improvement Cost: $240,000,  Roadway Improvement Cost: $24,000,  Total Project Cost: $360,000 ( Estimate for 2022),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 16642,  Location: S 6 T 61 N R 6 W (Lat: 40.120111,  Lng: -91.581361),  Route carried "on" structure: County highway 127,  Year Built: 1996,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 35 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 44 (year 2040),  Features Intersected: SUGAR CR,  Facility Carried by Structure: COUNTY RD 526
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.380,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 5.5m (18.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 2473,  Location: S 28 T 62 N R 6 W (Lat: 40.142186,  Lng: -91.566000),  Route carried "on" structure: State highway 16,  Year Built: 1973,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 8.56m (28.08ft),  Average Daily Traffic: 1,703 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 2,469 (year 2041),  Design Load: H 20,  Features Intersected: WYACONDA RVR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.558,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.9m (107.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 2848,  Location: S 34 T 62 N R 6 W (Lat: 40.133983,  Lng: -91.540358),  Route carried "on" structure: State highway 16,  Year Built: 1974,  Status: Open,  Structure Length: 8.23m (27.00ft),  Average Daily Traffic: 2,667 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 3,867 (year 2041),  Design Load: H 20,  Features Intersected: US 61
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.017,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 41.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 25.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2849,  Location: S 34 T 62 N R 6 W (Lat: 40.123283,  Lng: -91.541497),  Route carried "on" structure: State highway P,  Year Built: 1974,  Status: Open,  Structure Length: 7.86m (25.79ft),  Average Daily Traffic: 458 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 664 (year 2041),  Design Load: H 20,  Features Intersected: US 61
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.040,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.7m (110.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 21.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 285,  Location: S 14 T 61 N R 6 W (Lat: 40.087800,  Lng: -91.535192),  Route carried "on" structure: County highway ,  Year Built: 1974,  Status: Open,  Structure Length: 8.26m (27.10ft),  Average Daily Traffic: 140 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 203 (year 2041),  Design Load: H 15,  Features Intersected: US 61,  Facility Carried by Structure: SUNFLOWER ST E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.376,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 33.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 18.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 2851,  Location: S 14 T 61 N R 6 W (Lat: 40.084317,  Lng: -91.535933),  Route carried "on" structure: US 61,  Year Built: 1974,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 8.78m (28.81ft),  Average Daily Traffic: 5,792 (year 2021),  Truck Traffic: 38%,  Average Future Daily Traffic: 11,005 (year 2041),  Design Load: HS 20,  Features Intersected: WYACONDA RVR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 46.615,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.1m (111.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Internally Sealed
Find on map >>   Show street view

Structure Number: 29111,  Location: S 14 T 61 N R 6 W (Lat: 40.084311,  Lng: -91.535622),  Route carried "on" structure: US 61,  Year Built: 2001,  Status: Open,  Structure Length: 8.69m (28.51ft),  Average Daily Traffic: 5,899 (year 2021),  Truck Traffic: 33%,  Average Future Daily Traffic: 11,208 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: WACONDA RVR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 587.410,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.0m (111.5ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Satisfactory,  Operating Rating: 91.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 30148,  Location: S 11 T 61 N R 6 W (Lat: 40.093028,  Lng: -91.514861),  Route carried "on" structure: County highway 207,  Year Built: 2003,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 35 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 44 (year 2040),  Features Intersected: BRANCH,  Facility Carried by Structure: COUNTY RD 552
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.150,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 31046,  Location: S 14 T 62 N R 6 W (Lat: 40.173244,  Lng: -91.526814),  Route carried "on" structure: US 61,  Year Built: 2005,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 7,557 (year 2021),  Truck Traffic: 32%,  Average Future Daily Traffic: 14,358 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: ARTESIAN BR CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 36.447,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Inventory Rating: 93.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 31049,  Location: S 11 T 62 N R 6 W (Lat: 40.177789,  Lng: -91.524744),  Route carried "on" structure: US 61,  Year Built: 2005,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 9,735 (year 2021),  Truck Traffic: 32%,  Average Future Daily Traffic: 18,497 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: BLAND BR CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 35.909,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Inventory Rating: 64.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 3105,  Location: S 2 T 62 N R 6 W (Lat: 40.194972,  Lng: -91.521739),  Route carried "on" structure: US 61,  Year Built: 2005,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 9,735 (year 2021),  Truck Traffic: 32%,  Average Future Daily Traffic: 18,497 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: UNNAMED CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.952,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Inventory Rating: 64.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 7687,  Location: S 3241 T 41 N R 20 W (Lat: 38.277367,  Lng: -93.151111),  Route carried "on" structure: State highway B,  Year Built: 1954,  Status: Open,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 248 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 397 (year 2041),  Design Load: H 10,  Features Intersected: KNOBBY CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.928,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 39.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 7823,  Location: S 10 T 52 N R 9 W (Lat: 39.294656,  Lng: -91.910308),  Route carried "on" structure: State highway Z,  Year Built: 1954,  Status: Open,  Structure Length: 0.75m (2.46ft),  Average Daily Traffic: 277 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 402 (year 2041),  Design Load: H 10,  Features Intersected: FIVE MILE CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.102,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 34.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 8186,  Location: S 33 T 62 N R 6 W (Lat: 40.121261,  Lng: -91.565883),  Route carried "on" structure: State highway P,  Year Built: 1963,  Status: Posted for load,  Structure Length: 10.39m (34.09ft),  Average Daily Traffic: 458 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 664 (year 2041),  Design Load: H 15,  Features Intersected: WYACONDA RVR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.192,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 20.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 12.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CEPNCRMO-000003,  Location: L/D No. 20, Canton, MO (Lat: 40.140522,  Lng: -91.516008),  Route carried "on" structure: Federal lands road ,  Year Built: 1937,  Status: Open,  Structure Length: 3.56m (11.68ft),  Average Daily Traffic: 100 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 100 (year 2039),  Design Load: H 15,  Features Intersected: Canton Creek,  Facility Carried by Structure: Lock Access Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Corps of Engineers (Civil),  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Very good,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 3.56m (11.68ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $125,000,  Roadway Improvement Cost: $13,000,  Total Project Cost: $188,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2848,  Location: S 34 T 62 N R 6 W (Lat: 40.133983,  Lng: -91.540358),  Route carried "under" structure: US 61,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 4,627 (year 2021),  Truck Traffic: 31%,  Features Intersected: US 61,  Facility Carried by Structure: MO 16 E
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 593.109,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.3m (115.8ft)

Find on map >>   Show street view

Structure Number: 2848,  Location: S 34 T 62 N R 6 W (Lat: 40.133983,  Lng: -91.540358),  Route carried "under" structure: US 61,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 3,757 (year 2021),  Truck Traffic: 32%,  Features Intersected: US 61,  Facility Carried by Structure: MO 16 E
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 41.008,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.3m (115.8ft)

Find on map >>   Show street view

Structure Number: 2849,  Location: S 34 T 62 N R 6 W (Lat: 40.123283,  Lng: -91.541497),  Route carried "under" structure: US 61,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 5,783 (year 2021),  Truck Traffic: 38%,  Features Intersected: US 61,  Facility Carried by Structure: RT P S
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 42.197,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.7m (110.6ft)

Find on map >>   Show street view

Structure Number: 2849,  Location: S 34 T 62 N R 6 W (Lat: 40.123283,  Lng: -91.541497),  Route carried "under" structure: US 61,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 5,899 (year 2021),  Truck Traffic: 33%,  Features Intersected: US 61,  Facility Carried by Structure: RT P S
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 591.916,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.7m (110.6ft)

Find on map >>   Show street view

Structure Number: 285,  Location: S 14 T 61 N R 6 W (Lat: 40.087800,  Lng: -91.535192),  Route carried "under" structure: US 61,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 5,792 (year 2021),  Truck Traffic: 38%,  Features Intersected: US 61,  Facility Carried by Structure: SUNFLOWER ST E
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 46.270,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.3m (115.8ft)

Find on map >>   Show street view

Structure Number: 285,  Location: S 14 T 61 N R 6 W (Lat: 40.087800,  Lng: -91.535192),  Route carried "under" structure: US 61,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 5,899 (year 2021),  Truck Traffic: 33%,  Features Intersected: US 61,  Facility Carried by Structure: SUNFLOWER ST E
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 587.846,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.3m (115.8ft)

Discuss Canton, Missouri (MO) on our hugely popular Missouri forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.