Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Carbondale, Kansas (KS)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 25Number of bridges
  • 203ft / 61.9mTotal length
  • $310,000Total costs
  • 48,289Total average daily traffic
  • 5,908Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Carbondale
  • No street view available for this location

New bridges in Carbondale, KS - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11930-1939
  • 31940-1949
  • 11960-1969
  • 131970-1979
  • 31990-1999
  • 12000-2009
  • 22010-2019
Average Bridge Daily Traffic in Carbondale, KS
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Very good
  • 58.3%Good
  • 8.3%Satisfactory
  • 8.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 16.7%Very good
  • 66.7%Good
  • 8.3%Satisfactory
  • 8.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 41.7%Very good
  • 41.7%Good
  • 8.3%Satisfactory
  • 8.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 15.4%Very good
  • 30.8%Good
  • 38.5%Satisfactory
  • 15.4%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 44.4%Very good
  • 44.4%Good
  • 11.1%Satisfactory
Find on map >>   Show street view

Structure Number: 70026,  Location: 1.9W OF CARBONDALE (Lat: 38.826033,  Lng: -95.730931),  Route carried "on" structure: County highway 1248,  Year Built: 1948,  Status: Posted for load,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 130 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 156 (year 2039),  Design Load: H 10,  Features Intersected: TOW HEAD CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 19.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 11.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 70027,  Location: 1.8W OF CARBONDALE (Lat: 38.826072,  Lng: -95.728983),  Route carried "on" structure: County highway 1248,  Year Built: 1948,  Status: Posted for load,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 130 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 156 (year 2039),  Design Load: H 10,  Features Intersected: TOW HEAD CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 19.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 11.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 70028,  Location: AT CARBONDALE (Lat: 38.818961,  Lng: -95.693042),  Route carried "on" structure: County highway 1248,  Year Built: 1997,  Status: Open,  Structure Length: 1.02m (3.35ft),  Average Daily Traffic: 322 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 386 (year 2039),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 69.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 700501,  Location: 1.7S OF CARBONDALE (Lat: 38.786633,  Lng: -95.686525),  Route carried "on" structure: County highway 2076,  Year Built: 2014,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 1,655 (year 2013),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,986 (year 2039),  Design Load: HS 20,  Features Intersected: UNNAMED STREAM
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 70051,  Location: 0.8N OF CARBONDALE (Lat: 38.838408,  Lng: -95.686961),  Route carried "on" structure: County highway 2076,  Year Built: 2009,  Status: Open,  Structure Length: 2.51m (8.23ft),  Average Daily Traffic: 1,540 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,848 (year 2039),  Design Load: HS 20,  Features Intersected: BURY CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 7009917046,  Location: 1.0N 1.9W OF CARBONDALE (Lat: 38.840606,  Lng: -95.729831),  Route carried "on" structure: County highway ,  Year Built: 1965,  Status: Posted for load,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 40 (year 2016),  Average Future Daily Traffic: 48 (year 2039),  Features Intersected: PLUM CREEK,  Facility Carried by Structure: LOCAL RD. 134
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.3m (33.8ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 5.5m (18.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 7.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 4.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of replacement,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 2.31m (7.58ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: June 2020,  Bridge Improvement Cost: $200,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $310,000 ( Estimate for 2014),  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 70099740466,  Location: 1.0S 0.4E OF CARBONDALE (Lat: 38.797178,  Lng: -95.679044),  Route carried "on" structure: County highway ,  Year Built: 1940,  Status: Posted for load,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 60 (year 2013),  Average Future Daily Traffic: 72 (year 2040),  Features Intersected: Trib.110 mi Ck.,  Facility Carried by Structure: LOCAL RD. 180
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 20.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Other Special Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 7009976046,  Location: 1.0N 1.2E OF CARBONDALE (Lat: 38.840775,  Lng: -95.676533),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 60 (year 2013),  Average Future Daily Traffic: 72 (year 2039),  Design Load: HS 20,  Features Intersected: BURY'S CREEK,  Facility Carried by Structure: S 125 st. 92
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 67.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 7009979046,  Location: 4.0N 0.9E INT. US75-US56 (Lat: 38.840778,  Lng: -95.676528),  Route carried "on" structure: County highway ,  Year Built: 1935,  Status: Posted for load,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 40 (year 2013),  Average Future Daily Traffic: 48 (year 2040),  Features Intersected: TRIB. TO BURYS CREEK,  Facility Carried by Structure: 125th ST. 186
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 20.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Other Special Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 700999004587,  Location: 1.5N 1.5E OF CARBONDALE (Lat: 38.844542,  Lng: -95.667856),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 2.84m (9.32ft),  Average Daily Traffic: 50 (year 2013),  Average Future Daily Traffic: 60 (year 2040),  Design Load: HS 20,  Features Intersected: BURYS CREEK,  Facility Carried by Structure: S. Adams R 183
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 65.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 701003004623,  Location: 3.0E 0.2N OF CARBONDALE (Lat: 38.822203,  Lng: -95.630694),  Route carried "on" structure: County highway 7017,  Year Built: 1920,  Status: Posted for load,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 40 (year 2016),  Average Future Daily Traffic: 48 (year 2039),  Features Intersected: STROWBRIDGE CREEK,  Facility Carried by Structure: MINOR COL 60
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.1m (16.7ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.5m (31.2ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 8.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 4.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: June 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 999905600701201,  Location: 0.44 MI W JCT US-75 (Lat: 38.782500,  Lng: -95.690833),  Route carried "on" structure: US 56,  Year Built: 2011,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 2,190 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 2,568 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: 110 MILE CREEK DRAINAGE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 36.262,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.1m (10.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 22.6m (74.1ft)

Condition: Channel: Good,  Culverts: Very good,  Inventory Rating: 75.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 3.27m (10.73ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999907500700411,  Location: JCT US-56, SB (Lat: 38.782500,  Lng: -95.683056),  Route carried "on" structure: US 75,  Year Built: 1972,  Status: Open,  Structure Length: 7.05m (23.13ft),  Average Daily Traffic: 2,734 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 3,906 (year 2041),  Design Load: HS 20,  Features Intersected: US56 HWY
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 40.358,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 23.13m (75.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999907500700421,  Location: JCT US-56, NB (Lat: 38.782500,  Lng: -95.682778),  Route carried "on" structure: US 75,  Year Built: 1972,  Status: Open,  Structure Length: 7.05m (23.13ft),  Average Daily Traffic: 2,734 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 3,906 (year 2041),  Design Load: HS 20,  Features Intersected: US56 HWY
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 40.367,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 23.13m (75.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999907500700431,  Location: 1.00 MI N US56 (Lat: 38.796944,  Lng: -95.683056),  Route carried "on" structure: ServiceCounty highway 33,  Year Built: 1973,  Status: Open,  Structure Length: 8.20m (26.90ft),  Average Daily Traffic: 39 (year 2020),  Average Future Daily Traffic: 5,958 (year 2041),  Design Load: HS 20,  Features Intersected: US-75 HIGHWAY,  Facility Carried by Structure: LOCAL ROAD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 4.562,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.3m (92.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 26.90m (88.25ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 999907500700441,  Location: 2.02 MI N US-56 JCT, SB (Lat: 38.811667,  Lng: -95.683889),  Route carried "on" structure: US 75,  Year Built: 1971,  Status: Open,  Structure Length: 4.04m (13.25ft),  Average Daily Traffic: 4,146 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 5,924 (year 2041),  Design Load: HS 20,  Features Intersected: LOCAL ROAD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 43.586,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 13.25m (43.47ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999907500700451,  Location: 2.01 MI N US-56 JCT, NB (Lat: 38.811667,  Lng: -95.683611),  Route carried "on" structure: US 75,  Year Built: 1971,  Status: Open,  Structure Length: 4.04m (13.25ft),  Average Daily Traffic: 4,146 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 5,924 (year 2041),  Design Load: HS 20,  Features Intersected: LOCAL ROAD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 43.596,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 13.25m (43.47ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999907500700461,  Location: 2.51 MI N US56 (Lat: 38.818889,  Lng: -95.683889),  Route carried "on" structure: County highway 1459,  Year Built: 1972,  Status: Open,  Structure Length: 8.20m (26.90ft),  Average Daily Traffic: 2,312 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,958 (year 2041),  Design Load: HS 20,  Features Intersected: US75 HWY, NB-SB,  Facility Carried by Structure: RS1248 RT, & 1495
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.249,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 26.90m (88.25ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999907500700471,  Location: 3.87 MI N US56 (Lat: 38.838611,  Lng: -95.683333),  Route carried "on" structure: US 75,  Year Built: 1971,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 4,653 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 6,648 (year 2041),  Design Load: HS 20,  Features Intersected: BURYS CREEK DRAINAGE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 46.594,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 72.1m (236.5ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Inventory Rating: 65.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.70m (12.14ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 999907500700481,  Location: 4.02 MI N US-56 JCT, SB (Lat: 38.840833,  Lng: -95.683333),  Route carried "on" structure: US 75,  Year Built: 1972,  Status: Open,  Structure Length: 4.04m (13.25ft),  Average Daily Traffic: 4,653 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 6,648 (year 2041),  Design Load: HS 20,  Features Intersected: LOCAL ROAD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 46.817,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 13.25m (43.47ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999907500700491,  Location: 4.03 MI N US-56 JCT, NB (Lat: 38.840833,  Lng: -95.683056),  Route carried "on" structure: US 75,  Year Built: 1972,  Status: Open,  Structure Length: 4.04m (13.25ft),  Average Daily Traffic: 4,653 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 6,648 (year 2041),  Design Load: HS 20,  Features Intersected: LOCAL ROAD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 46.827,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 13.25m (43.47ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999907500700411,  Location: JCT US-56, SB (Lat: 38.782500,  Lng: -95.683056),  Route carried "under" structure: US 56,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 1,835 (year 2020),  Truck Traffic: 5%,  Features Intersected: US56 HWY,  Facility Carried by Structure: US-75 HWY, SB
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 36.954,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 999907500700421,  Location: JCT US-56, NB (Lat: 38.782500,  Lng: -95.682778),  Route carried "under" structure: US 56,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 1,835 (year 2020),  Truck Traffic: 5%,  Features Intersected: US56 HWY,  Facility Carried by Structure: US-75 HWY, NB
Minimum Vertical Clearance: 4.83m (15.85ft),  Kilometerpoint: 36.981,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 999907500700431,  Location: 1.00 MI N US56 (Lat: 38.796944,  Lng: -95.683056),  Route carried "under" structure: US 75,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 4,146 (year 2020),  Truck Traffic: 14%,  Features Intersected: US-75 HIGHWAY,  Facility Carried by Structure: LOCAL ROAD
Minimum Vertical Clearance: 4.86m (15.94ft),  Kilometerpoint: 41.981,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 999907500700461,  Location: 2.51 MI N US56 (Lat: 38.818889,  Lng: -95.683889),  Route carried "under" structure: US 75,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 4,146 (year 2020),  Truck Traffic: 14%,  Features Intersected: US75 HWY, NB-SB,  Facility Carried by Structure: RS1248 RT, & 1495
Minimum Vertical Clearance: 4.87m (15.98ft),  Kilometerpoint: 44.405,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 28.0m (91.9ft)