Bridge Statistics for Carnegie, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 25Number of bridges
  • 367ft / 112mTotal length
  • $9,403,000Total costs
  • 410,157Total average daily traffic
  • 35,595Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Carnegie
  • No street view available for this location

New bridges in Carnegie, PA - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11920-1929
  • 11930-1939
  • 31950-1959
  • 11960-1969
  • 91970-1979
  • 21980-1989
  • 11990-1999
  • 62000-2009
Reconstructed bridges in Carnegie, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 01980-1989
  • 21990-1999
  • 22000-2009
  • 32010-2019
Average Bridge Daily Traffic in Carnegie, PA
Average Bridge Truck Traffic in Carnegie, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 8.3%Very good
  • 50.0%Good
  • 25.0%Satisfactory
  • 8.3%Fair
  • 8.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 25.0%Good
  • 50.0%Satisfactory
  • 16.7%Fair
  • 8.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 8.3%Very good
  • 8.3%Good
  • 75.0%Satisfactory
  • 8.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 12.5%Very good
  • 25.0%Good
  • 12.5%Satisfactory
  • 37.5%Fair
  • 12.5%Poor
Find on map >>   Show street view

Structure Number: 975,  Location: POC RR,BELL&ARCH ST (Lat: 40.415000,  Lng: -80.084222),  Route carried "on" structure: Interstate 376,  Year Built: 1952,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 15.54m (50.98ft),  Average Daily Traffic: 105,201 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 97,504 (year 2032),  Design Load: HS 20,  Features Intersected: BUSWY,ARCH,BELL,POC RR,  Facility Carried by Structure: PENN LINC PW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.424,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 1,  Length of Maximum Span: 32.3m (106.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 22.0m (72.2ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 74.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 15.50m (50.85ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $247,000,  Roadway Improvement Cost: $726,000,  Total Project Cost: $3,330,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1782,  Location: AT I-79 INTERCHANGE (Lat: 40.399283,  Lng: -80.103172),  Route carried "on" structure: State highway ,  Year Built: 1972,  Year Reconstructed: 2021,  Status: Open,  Structure Length: 9.20m (30.18ft),  Average Daily Traffic: 16,062 (year 2022),  Truck Traffic: 6%,  Average Future Daily Traffic: 11,640 (year 2039),  Design Load: HL 93,  Features Intersected: ROBINSON RUN,  Facility Carried by Structure: NOBLESTOWN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.688,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 24.1m (79.1ft),  Skew: 23 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 40.8m (133.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 22.4m (73.5ft),  Out-to-Out Width: 23.6m (77.4ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 9.20m (30.18ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $243,000,  Roadway Improvement Cost: $715,000,  Total Project Cost: $3,277,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1784,  Location: O/CHARTIERS CR SR 3048 (Lat: 40.407750,  Lng: -80.088286),  Route carried "on" structure: State highway ,  Year Built: 1967,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 6.00m (19.69ft),  Average Daily Traffic: 10,683 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 16,462 (year 2032),  Design Load: HS 20,  Features Intersected: CHARTIERS CREEK,  Facility Carried by Structure: MANSFIELD BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.871,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Skew: 23 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.0m (95.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 22.9m (75.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 95.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.00m (19.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $43,000,  Roadway Improvement Cost: $127,000,  Total Project Cost: $583,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1796,  Location: 1/4 MI. N. CARN. I-79 INT (Lat: 40.404703,  Lng: -80.107347),  Route carried "on" structure: State highway ,  Year Built: 1972,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 11.67m (38.29ft),  Average Daily Traffic: 2,137 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,631 (year 2032),  Design Load: HL 93,  Features Intersected: SR 0079 NB-SB,  Facility Carried by Structure: EWING ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.009,  Lanes on structure: 2,  Lanes under structure: 12,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 43.3m (142.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 98.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 11.60m (38.06ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $97,000,  Roadway Improvement Cost: $284,000,  Total Project Cost: $1,304,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1798,  Location: 2300'SOUTH OF SR 3058 (Lat: 40.407036,  Lng: -80.076253),  Route carried "on" structure: State highway ,  Year Built: 1992,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 10,750 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 16,506 (year 2032),  Design Load: HS 20,  Features Intersected: WHEELING & LE RR,  Facility Carried by Structure: FORSYTHE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.694,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.50m (11.48ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2564,  Location: CC04 CHARTIERS CRK # 4 (Lat: 40.411883,  Lng: -80.084125),  Route carried "on" structure: City street ,  Year Built: 1983,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 5,924 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 10,314 (year 2028),  Design Load: HS 20,  Features Intersected: CHARTIERS CREEK,  Facility Carried by Structure: CHESTNUT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 5.60m (18.37ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: March 2021,  Underwater Inspection Date: May 2017,  Bridge Improvement Cost: $33,000,  Roadway Improvement Cost: $98,000,  Total Project Cost: $448,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2565,  Location: CC06 CHARTIERS CRK # 6 (Lat: 40.402236,  Lng: -80.088639),  Route carried "on" structure: City street ,  Year Built: 1927,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 8,513 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 14,821 (year 2026),  Design Load: HS 20,  Features Intersected: CHARTIERS CREEK,  Facility Carried by Structure: CAROTHERS ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.7m (140.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 4.40m (14.44ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Critical Feature Inspection Date: December 2020,  Bridge Improvement Cost: $14,000,  Roadway Improvement Cost: $40,000,  Total Project Cost: $186,000,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 2566,  Location: CC16 CHARTIERS CRK # 16 (Lat: 40.400408,  Lng: -80.096878),  Route carried "on" structure: City street ,  Year Built: 1984,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 4.39m (14.40ft),  Average Daily Traffic: 3,127 (year 2005),  Truck Traffic: 6%,  Average Future Daily Traffic: 5,444 (year 2022),  Design Load: HS 20,  Features Intersected: CHARTIERS CREEK,  Facility Carried by Structure: HAMMOND ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.1m (79.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 92.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 4.40m (14.44ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: March 2021,  Underwater Inspection Date: May 2020,  Bridge Improvement Cost: $9,000,  Roadway Improvement Cost: $28,000,  Total Project Cost: $118,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2567,  Location: CM03 INT CAMPBELLS RN R (Lat: 40.408061,  Lng: -80.090139),  Route carried "on" structure: City street ,  Year Built: 1902,  Year Reconstructed: 1957,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 2,938 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,673 (year 2039),  Design Load: HS 20,  Features Intersected: CAMPBELLS RUN,  Facility Carried by Structure: RAILROAD AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.2m (53.1ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.10m (6.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $12,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $157,000,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 42057,  Location: 1/4 MILE SW CARNEGIE (Lat: 40.406767,  Lng: -80.088058),  Route carried "on" structure: City street ,  Year Built: 1934,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 4.21m (13.81ft),  Average Daily Traffic: 1,200 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,325 (year 2041),  Features Intersected: CHARTIERS CREEK,  Facility Carried by Structure: EAST MAIN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 4.8m (15.7ft),  Right: 4.8m (15.7ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Channel: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.90m (16.08ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Underwater Inspection Date: June 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 45197,  Location: 79/376 INTERCHANGE (Lat: 40.416667,  Lng: -80.106667),  Route carried "on" structure: Ramp State highway ,  Year Built: 2008,  Status: Open,  Structure Length: 45.29m (148.59ft),  Average Daily Traffic: 6,065 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,529 (year 2032),  Design Load: HS 20,  Features Intersected: I-79,376E&W, CAMBLS RNRD,  Facility Carried by Structure: SR 8009 RAMP G
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 13,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 72.5m (237.9ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 45929,  Location: 1 mile north of Glendale (Lat: 40.410297,  Lng: -80.091717),  Route carried "on" structure: City street ,  Year Built: 1973,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 150 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 160 (year 2041),  Design Load: HL 93,  Features Intersected: Trib of Chartiers Cr,  Facility Carried by Structure: Morrow St
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 866,  Location: I 79 NB OVER SR 3048 (Lat: 40.398525,  Lng: -80.104769),  Route carried "under" structure: State highway ,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 7,207 (year 2022),  Truck Traffic: 5%,  Features Intersected: SR 3048-NOBLESTOWN RD.,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 9.688,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 866,  Location: I 79 NB OVER SR 3048 (Lat: 40.398525,  Lng: -80.104769),  Route carried "under" structure: State highway ,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 2,677 (year 2022),  Truck Traffic: 10%,  Features Intersected: SR 3048-NOBLESTOWN RD.,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 5.87m (19.26ft),  Kilometerpoint: 9.688,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 868,  Location: I 79 SB OVER SR 3048 (Lat: 40.400000,  Lng: -80.100000),  Route carried "under" structure: State highway ,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 2,677 (year 2022),  Truck Traffic: 10%,  Features Intersected: NOBLESTOWN RD.,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 9.688,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 868,  Location: I 79 SB OVER SR 3048 (Lat: 40.400000,  Lng: -80.100000),  Route carried "under" structure: State highway ,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 7,207 (year 2022),  Truck Traffic: 5%,  Features Intersected: NOBLESTOWN RD.,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 9.688,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 975,  Location: POC RR,BELL&ARCH ST (Lat: 40.415000,  Lng: -80.084222),  Route carried "under" structure: City street ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 50 (year 2017),  Features Intersected: BUSWY,ARCH,BELL,POC RR,  Facility Carried by Structure: PENN LINC PW
Minimum Vertical Clearance: 12.74m (41.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.3m (106.0ft)

Find on map >>   Show street view

Structure Number: 975,  Location: POC RR,BELL&ARCH ST (Lat: 40.415000,  Lng: -80.084222),  Route carried "under" structure: City street ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2017),  Truck Traffic: 5%,  Features Intersected: BUSWY,ARCH,BELL,POC RR,  Facility Carried by Structure: PENN LINC PW
Minimum Vertical Clearance: 12.25m (40.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.3m (106.0ft)

Find on map >>   Show street view

Structure Number: 1796,  Location: 1/4 MI. N. CARN. I-79 INT (Lat: 40.404703,  Lng: -80.107347),  Route carried "under" structure: Interstate 79,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 36,259 (year 2022),  Truck Traffic: 12%,  Features Intersected: SR 0079 NB-SB,  Facility Carried by Structure: EWING ROAD
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 11.074,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.3m (142.1ft)

Find on map >>   Show street view

Structure Number: 1796,  Location: 1/4 MI. N. CARN. I-79 INT (Lat: 40.404703,  Lng: -80.107347),  Route carried "under" structure: Interstate 79,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 33,286 (year 2022),  Truck Traffic: 12%,  Features Intersected: SR 0079 NB-SB,  Facility Carried by Structure: EWING ROAD
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 11.080,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.3m (142.1ft)

Find on map >>   Show street view

Structure Number: 45197,  Location: 79/376 INTERCHANGE (Lat: 40.416667,  Lng: -80.106667),  Route carried "under" structure: Interstate 376,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 38,532 (year 2022),  Truck Traffic: 9%,  Features Intersected: I-79,376E&W, CAMBLS RNRD,  Facility Carried by Structure: SR 8009 RAMP G
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.018,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 72.5m (237.9ft)

Find on map >>   Show street view

Structure Number: 45197,  Location: 79/376 INTERCHANGE (Lat: 40.416667,  Lng: -80.106667),  Route carried "under" structure: Ramp State highway ,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 4,585 (year 2021),  Truck Traffic: 7%,  Features Intersected: I-79,376E&W, CAMBLS RNRD,  Facility Carried by Structure: SR 8009 RAMP G
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 72.5m (237.9ft)

Find on map >>   Show street view

Structure Number: 45197,  Location: 79/376 INTERCHANGE (Lat: 40.416667,  Lng: -80.106667),  Route carried "under" structure: Interstate 79,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 31,419 (year 2021),  Truck Traffic: 14%,  Features Intersected: I-79,376E&W, CAMBLS RNRD,  Facility Carried by Structure: SR 8009 RAMP G
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.481,  Lanes on structure: 1,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 72.5m (237.9ft)

Find on map >>   Show street view

Structure Number: 45197,  Location: 79/376 INTERCHANGE (Lat: 40.416667,  Lng: -80.106667),  Route carried "under" structure: Interstate 79,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 34,254 (year 2021),  Truck Traffic: 17%,  Features Intersected: I-79,376E&W, CAMBLS RNRD,  Facility Carried by Structure: SR 8009 RAMP G
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.488,  Lanes on structure: 1,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 72.5m (237.9ft)

Find on map >>   Show street view

Structure Number: 45197,  Location: 79/376 INTERCHANGE (Lat: 40.416667,  Lng: -80.106667),  Route carried "under" structure: Interstate 376,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 38,254 (year 2022),  Truck Traffic: 9%,  Features Intersected: I-79,376E&W, CAMBLS RNRD,  Facility Carried by Structure: SR 8009 RAMP G
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.031,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 72.5m (237.9ft)

Discuss Carnegie, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.