Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Chamberlayne, Virginia (VA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 292ft / 88.8mTotal length
  • $3,279,000Total costs
  • 651,930Total average daily traffic
  • 51,887Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Chamberlayne
  • No street view available for this location

New bridges in Chamberlayne, VA - historical statistics
  • New bridges - historical statistics
  • 11950-1959
  • 131960-1969
  • 41970-1979
Reconstructed bridges in Chamberlayne, VA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21980-1989
  • 01990-1999
  • 42000-2009
Average Bridge Daily Traffic in Chamberlayne, VA
Average Bridge Truck Traffic in Chamberlayne, VA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 41.7%Good
  • 41.7%Satisfactory
  • 16.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 25.0%Very good
  • 8.3%Good
  • 16.7%Satisfactory
  • 50.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 33.3%Good
  • 25.0%Satisfactory
  • 41.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 9.1%Very good
  • 18.2%Good
  • 54.5%Satisfactory
  • 18.2%Fair
Find on map >>   Show street view

Structure Number: 9448,  Location: .0 HenricCo&.0Hanover Co (Lat: 37.653389,  Lng: -77.431247),  Route carried "on" structure: Interstate 295,  Year Built: 1979,  Status: Open,  Structure Length: 12.89m (42.29ft),  Average Daily Traffic: 43,066 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 60,292 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CHICKAHOMINY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.007,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 25.0m (82.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 63.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9449,  Location: 0.0FrHenrico&0.0ToHanover (Lat: 37.652631,  Lng: -77.430825),  Route carried "on" structure: Interstate 295,  Year Built: 1979,  Status: Open,  Structure Length: 12.89m (42.29ft),  Average Daily Traffic: 43,704 (year 2020),  Average Future Daily Traffic: 61,186 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CHICKAHOMINY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.039,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 25.0m (82.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9462,  Location: 0.0 HANOVE CO 0.0HENRIC C (Lat: 37.641411,  Lng: -77.422033),  Route carried "on" structure: US 301,  Year Built: 1978,  Status: Open,  Structure Length: 9.22m (30.25ft),  Average Daily Traffic: 13,978 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 19,571 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CHICKAHOMINY RIVER,  Facility Carried by Structure: SBL CHAMBERLAYNE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 133.085,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 9463,  Location: 0.0 HANOVE CO 0.0HENRIC C (Lat: 37.641217,  Lng: -77.421914),  Route carried "on" structure: US 301,  Year Built: 1978,  Status: Open,  Structure Length: 9.22m (30.25ft),  Average Daily Traffic: 13,978 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 19,571 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CHICKAHOMINY RIVER,  Facility Carried by Structure: NBL CHAMBERLAYNE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 133.085,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 9603,  Location: .6 FR 301 .33 TO UPHAM DR (Lat: 37.617389,  Lng: -77.442456),  Route carried "on" structure: ServiceCounty highway F653,  Year Built: 1962,  Status: Open,  Structure Length: 3.29m (10.79ft),  Average Daily Traffic: 782 (year 2020),  Average Future Daily Traffic: 1,095 (year 2040),  Design Load: H 20,  Features Intersected: UPHAM BROOK,  Facility Carried by Structure: ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.965,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.5m (54.1ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.29m (10.79ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $435,000,  Roadway Improvement Cost: $140,000,  Total Project Cost: $702,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 9661,  Location: 0.72 N of Azalea Ave. (Lat: 37.613278,  Lng: -77.424114),  Route carried "on" structure: County highway 75940,  Year Built: 1954,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 5,915 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 6,506 (year 2040),  Design Load: HS 20,  Features Intersected: UPHAM BROOK,  Facility Carried by Structure: WILKINSON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.047,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 39.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.98m (3.22ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $945,000,  Roadway Improvement Cost: $110,000,  Total Project Cost: $1,372,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 9832,  Location: 0.84 (301)SBL0.45 73 EBL (Lat: 37.629506,  Lng: -77.449117),  Route carried "on" structure: Interstate 95,  Year Built: 1962,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 44,010 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 61,614 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WILKINSON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 133.434,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 16.4m (53.8ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 9834,  Location: 0.84 (301)SBL0.45 73 EBL (Lat: 37.629514,  Lng: -77.448836),  Route carried "on" structure: Interstate 95,  Year Built: 1962,  Status: Open,  Structure Length: 4.40m (14.44ft),  Average Daily Traffic: 44,864 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 62,810 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WILKINSON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 133.434,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 9836,  Location: 1.1 FR 1 / 1.29 TO 73 EBL (Lat: 37.618081,  Lng: -77.444011),  Route carried "on" structure: Interstate 95,  Year Built: 1962,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 3.52m (11.55ft),  Average Daily Traffic: 44,010 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 61,614 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UPHAM BROOK
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 132.131,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.1m (36.4ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 90.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 69.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.51m (11.52ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $75,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $85,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9837,  Location: 1.1 FR 1 / 1.29 TO 73 EBL (Lat: 37.618033,  Lng: -77.443786),  Route carried "on" structure: Interstate 95,  Year Built: 1962,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 3.51m (11.52ft),  Average Daily Traffic: 44,864 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 62,810 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UPHAM BROOK
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 132.099,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.1m (36.4ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 90.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 69.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9845,  Location: .60 TO 2(301) 7 1.10 TO73 (Lat: 37.621058,  Lng: -77.444306),  Route carried "on" structure: Interstate 95,  Year Built: 1962,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 88,874 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 114,969 (year 2040),  Design Load: HS 20,  Features Intersected: FLIPPEN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 132.421,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 33.5m (109.9ft),  Skew: 24 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 10008,  Location: 0.44 TO I-95 & 0.71 NCL R (Lat: 37.611392,  Lng: -77.447006),  Route carried "on" structure: Alternate US 301,  Year Built: 1962,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 11.51m (37.76ft),  Average Daily Traffic: 12,000 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,300 (year 2034),  Design Load: HS 20+Mod,  Features Intersected: RTE I 95,  Facility Carried by Structure: SBL CHAMBERLAYNE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 131.327,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 36.0m (118.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 11.49m (37.70ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $200,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $300,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1001,  Location: 0.88WILKSN RD0.44I-95 (Lat: 37.617933,  Lng: -77.444311),  Route carried "on" structure: US 301,  Year Built: 1962,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 9.21m (30.22ft),  Average Daily Traffic: 14,000 (year 2017),  Truck Traffic: 2%,  Average Future Daily Traffic: 18,000 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: RTE I 95 & UPHAM BROOK,  Facility Carried by Structure: SBL CHAMBERLAYNE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 129.787,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 9.20m (30.18ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $200,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $300,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 10012,  Location: 1.37FR WILMR&0.32TO UPHM (Lat: 37.617367,  Lng: -77.442617),  Route carried "on" structure: US 301,  Year Built: 1962,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 3.31m (10.86ft),  Average Daily Traffic: 4,885 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,839 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UPHAM BROOK,  Facility Carried by Structure: NBL CHAMBERLAYNE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 129.814,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 76.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 59.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.29m (10.79ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $360,000,  Roadway Improvement Cost: $85,000,  Total Project Cost: $520,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Other Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9832,  Location: 0.84 (301)SBL0.45 73 EBL (Lat: 37.629506,  Lng: -77.449117),  Route carried "under" structure: County highway ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2017),  Truck Traffic: 2%,  Features Intersected: WILKINSON ROAD,  Facility Carried by Structure: SBL I-95
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 0.805,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 13.4m (44.0ft)

Find on map >>   Show street view

Structure Number: 9834,  Location: 0.84 (301)SBL0.45 73 EBL (Lat: 37.629514,  Lng: -77.448836),  Route carried "under" structure: County highway ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2017),  Truck Traffic: 1%,  Features Intersected: WILKINSON ROAD,  Facility Carried by Structure: NBL I-95
Minimum Vertical Clearance: 6.43m (21.10ft),  Kilometerpoint: 0.805,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 14.3m (46.9ft)

Find on map >>   Show street view

Structure Number: 10008,  Location: 0.44 TO I-95 & 0.71 NCL R (Lat: 37.611392,  Lng: -77.447006),  Route carried "under" structure: Interstate 95,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 108,000 (year 2019),  Truck Traffic: 9%,  Features Intersected: RTE I 95,  Facility Carried by Structure: SBL CHAMBERLAYNE
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 131.327,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>   Show street view

Structure Number: 1001,  Location: 0.88WILKSN RD0.44I-95 (Lat: 37.617933,  Lng: -77.444311),  Route carried "under" structure: Interstate 95,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 108,000 (year 2017),  Truck Traffic: 9%,  Features Intersected: RTE I 95 & UPHAM BROOK,  Facility Carried by Structure: SBL CHAMBERLAYNE
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 132.147,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Discuss Chamberlayne, Virginia (VA) on our hugely popular Virginia forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.