Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Cheval, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 82ft / 24.7mTotal length
  • 141,000Total average daily traffic
  • 14,134Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Cheval
  • No street view available for this location

New bridges in Cheval, FL - historical statistics
  • New bridges - historical statistics
  • 81990-1999
  • 52000-2009
Average Bridge Daily Traffic in Cheval, FL
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 60.0%Very good
  • 40.0%Good
Find on map >>   Show street view

Structure Number: 100513,  Location: 0.5 MI W OF DALE MABRY (Lat: 28.134164,  Lng: -82.510422),  Route carried "on" structure: Spur State highway 568,  Year Built: 1994,  Status: Open,  Structure Length: 2.56m (8.40ft),  Average Daily Traffic: 6,250 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 10,844 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: CALUSA TRACE BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.064,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.6m (41.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 100571,  Location: 1.2 MI W OF DALE MABRY (Lat: 28.132586,  Lng: -82.522356),  Route carried "on" structure: Spur State highway 568,  Year Built: 1994,  Status: Open,  Structure Length: 5.93m (19.46ft),  Average Daily Traffic: 6,250 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 10,844 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LAKE REFLECTIONS BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.853,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.7m (84.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 37.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 100572,  Location: 1.2 MI W OF DALE MABRY (Lat: 28.132328,  Lng: -82.522442),  Route carried "on" structure: Spur State highway 568,  Year Built: 1994,  Status: Open,  Structure Length: 6.03m (19.78ft),  Average Daily Traffic: 6,250 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 10,844 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LAKE REFLECTIONS BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.834,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.3m (86.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 32.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 10063,  Location: 1.6 MI N OF VAN DYKE (Lat: 28.150089,  Lng: -82.540642),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 3.92m (12.86ft),  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 38,430 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: TPC BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.216,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.2m (128.6ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 100631,  Location: 1.6 MI N OF VAN DYKE (Lat: 28.150256,  Lng: -82.540842),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 3.92m (12.86ft),  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 38,430 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: TPC BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.216,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.3m (40.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.2m (128.6ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 43.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 104297,  Location: .3 MI NW OF CALUSA TRC BL (Lat: 28.142008,  Lng: -82.510464),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 150 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 188 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: BITTERN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Underwater Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 104607,  Location: 0.3Mi N ofLutz Lk.Fern Rd (Lat: 28.160194,  Lng: -82.495197),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 1.05m (3.44ft),  Average Daily Traffic: 12,000 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 20,820 (year 2042),  Design Load: HL 93,  Features Intersected: Sun Lake Canal,  Facility Carried by Structure: Sun Lake Blvd.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.563,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.9m (16.1ft),  Curb or Sidewalk Widths: Left: 5.0m (16.4ft),  Right: 5.0m (16.4ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 33.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Underwater Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 100512,  Location: 0.5 MI W OF DALE MABRY (Lat: 28.134356,  Lng: -82.510389),  Route carried "under" structure: City street ,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 5,950 (year 2018),  Truck Traffic: 9%,  Features Intersected: CALUSA TRACE BLVD,  Facility Carried by Structure: SR 568 SPUR WB 2.5
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Find on map >>   Show street view

Structure Number: 100513,  Location: 0.5 MI W OF DALE MABRY (Lat: 28.134164,  Lng: -82.510422),  Route carried "under" structure: City street ,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 5,950 (year 2018),  Truck Traffic: 9%,  Features Intersected: CALUSA TRACE BLVD,  Facility Carried by Structure: SR 568 SPUR EB 2.5
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Find on map >>   Show street view

Structure Number: 100571,  Location: 1.2 MI W OF DALE MABRY (Lat: 28.132586,  Lng: -82.522356),  Route carried "under" structure: City street ,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 4,800 (year 2014),  Truck Traffic: 8%,  Features Intersected: LAKE REFLECTIONS BLVD,  Facility Carried by Structure: SR 568 SPUR WB 1.8
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.7m (84.3ft)

Find on map >>   Show street view

Structure Number: 100572,  Location: 1.2 MI W OF DALE MABRY (Lat: 28.132328,  Lng: -82.522442),  Route carried "under" structure: City street ,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 4,800 (year 2014),  Truck Traffic: 8%,  Features Intersected: LAKE REFLECTIONS BLVD,  Facility Carried by Structure: SR 568 SPUR EB 1.8
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.3m (86.3ft)

Find on map >>   Show street view

Structure Number: 10063,  Location: 1.6 MI N OF VAN DYKE (Lat: 28.150089,  Lng: -82.540642),  Route carried "under" structure: County highway ,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Features Intersected: TPC BLVD,  Facility Carried by Structure: SR 589 NB SCP 15.8
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 23.181,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.2m (128.6ft)

Find on map >>   Show street view

Structure Number: 100631,  Location: 1.6 MI N OF VAN DYKE (Lat: 28.150256,  Lng: -82.540842),  Route carried "under" structure: County highway ,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Features Intersected: TPC BLVD,  Facility Carried by Structure: SR 589 SB SCP 15.8
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 23.210,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.2m (128.6ft)

Discuss Cheval, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.