  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 118ft / 36.3mTotal length
  • $6,701,000Total costs
  • 426,725Total average daily traffic
  • 38,935Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Churchill
  • No street view available for this location

New bridges in Churchill, PA - historical statistics
  • New bridges - historical statistics
  • 21940-1949
  • 81950-1959
  • 71960-1969
  • 12020-2022
Reconstructed bridges in Churchill, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 41970-1979
  • 01980-1989
  • 01990-1999
  • 32000-2009
Average Bridge Daily Traffic in Churchill, PA
Average Bridge Truck Traffic in Churchill, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 57.1%Good
  • 28.6%Satisfactory
  • 14.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 28.6%Good
  • 71.4%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 57.1%Good
  • 42.9%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Very good
  • 50.0%Fair
Find on map >>   Show street view

Structure Number: 1188,  Location: GREENSBURG PIKE OVER PKWY (Lat: 40.450000,  Lng: -79.858333),  Route carried "on" structure: State highway ,  Year Built: 1955,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 4.08m (13.39ft),  Average Daily Traffic: 6,799 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 5,103 (year 2032),  Design Load: HS 20,  Features Intersected: SR 0376 EB WB,  Facility Carried by Structure: GREENSBURG PIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.6m (129.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.9m (42.3ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Inventory Rating: 66.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.10m (13.45ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $22,000,  Roadway Improvement Cost: $65,000,  Total Project Cost: $299,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1189,  Location: CHURCHILL INTERCHANGE (Lat: 40.445322,  Lng: -79.848633),  Route carried "on" structure: Interstate 376,  Year Built: 1950,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 92,062 (year 2021),  Truck Traffic: 17%,  Average Future Daily Traffic: 56,787 (year 2032),  Design Load: HS 20,  Features Intersected: BEULAH ROAD,  Facility Carried by Structure: PARKWAY EAST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.975,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.6m (70.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 22.9m (75.1ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 5.20m (17.06ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $24,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $321,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1192,  Location: CHURCH HILL INTERCHANGE (Lat: 40.445619,  Lng: -79.846658),  Route carried "on" structure: Interstate 376,  Year Built: 1950,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 44,204 (year 2021),  Truck Traffic: 17%,  Average Future Daily Traffic: 24,956 (year 2032),  Design Load: HS 20,  Features Intersected: SR 2110 SH,  Facility Carried by Structure: PARKWAY EAST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.888,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.3m (128.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 4.00m (13.12ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Critical Feature Inspection Date: July 2021,  Bridge Improvement Cost: $28,000,  Roadway Improvement Cost: $82,000,  Total Project Cost: $377,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Galvanized Reinforcing
Find on map >>   Show street view

Structure Number: 1197,  Location: 376 OVER WB RAMP A (Lat: 40.442333,  Lng: -79.838167),  Route carried "on" structure: Interstate 376,  Year Built: 1961,  Year Reconstructed: 1976,  Status: Open,  Structure Length: 2.38m (7.81ft),  Average Daily Traffic: 48,591 (year 2022),  Truck Traffic: 8%,  Average Future Daily Traffic: 66,110 (year 2032),  Design Load: HS 20,  Features Intersected: RAMP A WB,  Facility Carried by Structure: PARKWAY EAST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.584,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 35 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 27.0m (88.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 70.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.40m (7.87ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $22,000,  Roadway Improvement Cost: $65,000,  Total Project Cost: $299,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1198,  Location: 1/2 MI. N.E. OF SR 2048 (Lat: 40.440278,  Lng: -79.833681),  Route carried "on" structure: Interstate 376,  Year Built: 1962,  Year Reconstructed: 1976,  Status: Open,  Structure Length: 10.12m (33.20ft),  Average Daily Traffic: 69,028 (year 2022),  Truck Traffic: 8%,  Average Future Daily Traffic: 66,083 (year 2032),  Design Load: HS 20,  Features Intersected: LR 395-RODI ROAD NB&SB,  Facility Carried by Structure: PENN LINCOLN PY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.584,  Lanes on structure: 6,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.1m (88.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 29.6m (97.1ft),  Out-to-Out Width: 31.4m (103.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 92.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 10.10m (33.14ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $310,000,  Roadway Improvement Cost: $912,000,  Total Project Cost: $4,180,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1574,  Location: OVER SR 2053 (Lat: 40.433514,  Lng: -79.820614),  Route carried "on" structure: US 22B,  Year Built: 1941,  Year Reconstructed: 1978,  Status: Open,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 34,740 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 36,265 (year 2032),  Design Load: HS 20,  Features Intersected: LR 395 & CHALFONT RUN,  Facility Carried by Structure: WILLIAM PENN HY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.646,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 29 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 32.6m (107.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.10m (26.57ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Critical Feature Inspection Date: July 2020,  Bridge Improvement Cost: $91,000,  Roadway Improvement Cost: $267,000,  Total Project Cost: $1,225,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2794,  Location: RAMP D OVER RODI RD.N.B. (Lat: 40.441522,  Lng: -79.828453),  Route carried "on" structure: Ramp State highway ,  Year Built: 1962,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 1,863 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,584 (year 2032),  Design Load: HS 20,  Features Intersected: RODI RD NB,  Facility Carried by Structure: RAMP D
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 1.40m (4.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 67521,  Location: 500' SO. OF BUS. RT.22 (Lat: 40.433194,  Lng: -79.820903),  Route carried "on" structure: State highway ,  Year Built: 2020,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 1,592 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,000 (year 2040),  Design Load: HL 93,  Features Intersected: CHALFONT RUN,  Facility Carried by Structure: SOUTH BEND LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 1188,  Location: GREENSBURG PIKE OVER PKWY (Lat: 40.450000,  Lng: -79.858333),  Route carried "under" structure: Interstate 376,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 47,862 (year 2022),  Truck Traffic: 4%,  Features Intersected: SR 0376 EB WB,  Facility Carried by Structure: GREENSBURG PIKE
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 47.281,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 1188,  Location: GREENSBURG PIKE OVER PKWY (Lat: 40.450000,  Lng: -79.858333),  Route carried "under" structure: Interstate 376,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 32,680 (year 2022),  Truck Traffic: 5%,  Features Intersected: SR 0376 EB WB,  Facility Carried by Structure: GREENSBURG PIKE
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 47.083,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 1189,  Location: CHURCHILL INTERCHANGE (Lat: 40.445322,  Lng: -79.848633),  Route carried "under" structure: State highway 130,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 3,858 (year 2020),  Truck Traffic: 2%,  Features Intersected: BEULAH ROAD,  Facility Carried by Structure: PARKWAY EAST
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 9.793,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 1189,  Location: CHURCHILL INTERCHANGE (Lat: 40.445322,  Lng: -79.848633),  Route carried "under" structure: State highway 130,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 3,858 (year 2020),  Truck Traffic: 2%,  Features Intersected: BEULAH ROAD,  Facility Carried by Structure: PARKWAY EAST
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 9.786,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 1192,  Location: CHURCH HILL INTERCHANGE (Lat: 40.445619,  Lng: -79.846658),  Route carried "under" structure: State highway ,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 9,979 (year 2020),  Truck Traffic: 3%,  Features Intersected: SR 2110 SH,  Facility Carried by Structure: PARKWAY EAST
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 2.580,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 39.3m (128.9ft)

Find on map >>   Show street view

Structure Number: 1197,  Location: 376 OVER WB RAMP A (Lat: 40.442333,  Lng: -79.838167),  Route carried "under" structure: Ramp US 22B,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 11,395 (year 2022),  Truck Traffic: 1%,  Features Intersected: RAMP A WB,  Facility Carried by Structure: PARKWAY EAST
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 1198,  Location: 1/2 MI. N.E. OF SR 2048 (Lat: 40.440278,  Lng: -79.833681),  Route carried "under" structure: State highway 791,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 5,547 (year 2020),  Truck Traffic: 1%,  Features Intersected: LR 395-RODI ROAD NB&SB,  Facility Carried by Structure: PENN LINCOLN PY
Minimum Vertical Clearance: 9.14m (29.99ft),  Kilometerpoint: 0.267,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 1198,  Location: 1/2 MI. N.E. OF SR 2048 (Lat: 40.440278,  Lng: -79.833681),  Route carried "under" structure: State highway 791,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 5,547 (year 2020),  Truck Traffic: 1%,  Features Intersected: LR 395-RODI ROAD NB&SB,  Facility Carried by Structure: PENN LINCOLN PY
Minimum Vertical Clearance: 9.14m (29.99ft),  Kilometerpoint: 0.267,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 1574,  Location: OVER SR 2053 (Lat: 40.433514,  Lng: -79.820614),  Route carried "under" structure: State highway ,  Year Built: 1941,  Structure Length: 0. m,  Average Daily Traffic: 1,573 (year 2022),  Truck Traffic: 5%,  Features Intersected: LR 395 & CHALFONT RUN,  Facility Carried by Structure: WILLIAM PENN HY
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 1.059,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 2794,  Location: RAMP D OVER RODI RD.N.B. (Lat: 40.441522,  Lng: -79.828453),  Route carried "under" structure: State highway 791,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 5,547 (year 2020),  Truck Traffic: 1%,  Features Intersected: RODI RD NB,  Facility Carried by Structure: RAMP D
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 0.267,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.4m (44.0ft)