Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Clearfield, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 23Number of bridges
  • 292ft / 88.6mTotal length
  • 949,688Total average daily traffic
  • 146,100Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Clearfield
  • No street view available for this location

New bridges in Clearfield, UT - historical statistics
  • New bridges - historical statistics
  • 131960-1969
  • 31970-1979
  • 11980-1989
  • 21990-1999
  • 12000-2009
  • 12010-2019
  • 22020-2022
Reconstructed bridges in Clearfield, UT - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 01980-1989
  • 01990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Clearfield, UT
Average Bridge Truck Traffic in Clearfield, UT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 21.4%Good
  • 42.9%Satisfactory
  • 35.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 7.1%Very good
  • 28.6%Good
  • 50.0%Satisfactory
  • 14.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.1%Very good
  • 28.6%Good
  • 42.9%Satisfactory
  • 21.4%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Very good
  • 50.0%Good
  • 25.0%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 11004E,  Location: 600 S.1000 E., CLEARFIELD (Lat: 41.104961,  Lng: -112.003706),  Route carried "on" structure: City street 1480,  Year Built: 1965,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 459 (year 2020),  Average Future Daily Traffic: 574 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER-DAVIS CANAL,  Facility Carried by Structure: 1000 EAST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.141,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.0m

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 23 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 11007F,  Location: 350 E.300 N., CLEARFIELD (Lat: 41.118058,  Lng: -112.020014),  Route carried "on" structure: City street ,  Year Built: 1965,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 1,008 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,225 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WEBER-DAVIS CANAL,  Facility Carried by Structure: 300 NORTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.034,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.7m (28.5ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 20.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 11009C,  Location: 600 W. 800 N., CLEARFIELD (Lat: 41.125322,  Lng: -112.035450),  Route carried "on" structure: City street 1492,  Year Built: 1985,  Status: Open,  Structure Length: 3.61m (11.84ft),  Average Daily Traffic: 6,639 (year 2020),  Average Future Daily Traffic: 8,299 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UPRR/Front Runner,  Facility Carried by Structure: 800 NORTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.478,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.5m (116.5ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 10.6m (34.8ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11018F,  Location: 260 E.BRUCE ST.CLEARFIELD (Lat: 41.120825,  Lng: -112.022778),  Route carried "on" structure: City street ,  Year Built: 1974,  Status: Open,  Structure Length: 1.32m (4.33ft),  Average Daily Traffic: 1,008 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,225 (year 2040),  Design Load: HL 93,  Features Intersected: WEBER-DAVIS CANAL,  Facility Carried by Structure: BRUCE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.055,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.1m (36.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 11023C,  Location: 200 W. CENTER, CLEARFIELD (Lat: 41.111600,  Lng: -112.026050),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 5.46m (17.91ft),  Average Daily Traffic: 2,520 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,062 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: UNION PACIFIC RAILROAD,  Facility Carried by Structure: 200 SOUTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.086,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.4m (37.4ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 53.6m (175.9ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 0.0m,  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 91.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C1005,  Location: W of State St. Clearfield (Lat: 41.103661,  Lng: -112.021275),  Route carried "on" structure: State highway 193,  Year Built: 2013,  Status: Open,  Structure Length: 5.41m (17.75ft),  Average Daily Traffic: 24,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 30,000 (year 2040),  Design Load: HL 93,  Features Intersected: UPRR & UTA TRACKS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.614,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 26.3m (86.3ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 53.1m (174.2ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 26.3m (86.3ft),  Out-to-Out Width: 30.1m (98.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E1901,  Location: IN CLEARFIELD (Lat: 41.108278,  Lng: -112.008253),  Route carried "on" structure: Interstate 15,  Year Built: 1964,  Year Reconstructed: 1972,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 114,229 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 142,786 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DAVIS-WEBER CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 538.787,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 38.1m (125.0ft),  Skew: 24 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.3m (33.8ft),  Curb-To-Curb Width: 38.1m (125.0ft),  Out-to-Out Width: 47.1m (154.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 26.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: F 33,  Location: 300 NO.ST.in CLEARFIELD (Lat: 41.118075,  Lng: -112.034917),  Route carried "on" structure: State highway 1489,  Year Built: 1974,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 28.93m (94.91ft),  Average Daily Traffic: 9,777 (year 2020),  Average Future Daily Traffic: 12,221 (year 2040),  Design Load: HL 93,  Features Intersected: CITY STREET AND UPRR,  Facility Carried by Structure: SR-107
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.101,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.7m (28.5ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: F 581,  Location: SO.SIDE FREEPORT CENTER (Lat: 41.089119,  Lng: -112.009314),  Route carried "on" structure: State highway 108,  Year Built: 1995,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 38,628 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 48,285 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UNION PACIFIC RAILROAD
Minimum Vertical Clearance: 30.18m (99.02ft),  Kilometerpoint: 1.809,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 26.2m (86.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.3m (73.2ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 26.2m (86.0ft),  Out-to-Out Width: 31.3m (102.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F 582,  Location: SO.SIDE FREEPORT CENTER (Lat: 41.089111,  Lng: -112.012475),  Route carried "on" structure: State highway 108,  Year Built: 1995,  Status: Open,  Structure Length: 5.88m (19.29ft),  Average Daily Traffic: 38,628 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 48,285 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ABANDONED UPRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.075,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 26.2m (86.0ft),  Skew: 23 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 26.2m (86.0ft),  Out-to-Out Width: 31.3m (102.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 36.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 23.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1D 719,  Location: HAFB Intch (650 North) (Lat: 41.122819,  Lng: -112.022678),  Route carried "on" structure: Interstate 15,  Year Built: 1966,  Status: Open,  Structure Length: 5.29m (17.36ft),  Average Daily Traffic: 114,229 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 142,786 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-103 W. GATE HILL AFB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 540.812,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.9m (78.4ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 37.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 18 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1D 747,  Location: 800 E. 200 SO. CLEARFIELD (Lat: 41.110178,  Lng: -112.009953),  Route carried "on" structure: Interstate 15,  Year Built: 1966,  Status: Open,  Structure Length: 3.99m (13.09ft),  Average Daily Traffic: 114,229 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 142,786 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: 200 SOUTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 539.042,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.2m (66.3ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.3m (50.2ft),  Curb-To-Curb Width: 20.2m (66.3ft),  Out-to-Out Width: 21.1m (69.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1F 63,  Location: CLEARFIELD INT. (700 SO) (Lat: 41.102542,  Lng: -112.002950),  Route carried "on" structure: Interstate 15,  Year Built: 1966,  Status: Open,  Structure Length: 6.20m (20.34ft),  Average Daily Traffic: 108,894 (year 2020),  Truck Traffic: 17%,  Average Future Daily Traffic: 136,118 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-193 700 SO.CLEARFIELD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 538.010,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.7m (58.1ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 35.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3D 719,  Location: HAFB Intch (650 North) (Lat: 41.124267,  Lng: -112.024433),  Route carried "on" structure: Interstate 15,  Year Built: 1966,  Status: Open,  Structure Length: 5.29m (17.36ft),  Average Daily Traffic: 114,229 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 142,786 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-103 W. GATE HILL AFB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 540.818,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.9m (78.4ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 37.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 18 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3F 63,  Location: CLEARFIELD INT (700 SO) (Lat: 41.104436,  Lng: -112.004997),  Route carried "on" structure: Interstate 15,  Year Built: 1966,  Status: Open,  Structure Length: 6.20m (20.34ft),  Average Daily Traffic: 108,894 (year 2020),  Truck Traffic: 17%,  Average Future Daily Traffic: 136,118 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-193,700 SO.CLEARFIELD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 538.071,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.7m (58.1ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3F 901,  Location: I-15 over 200 S (Lat: 41.110931,  Lng: -112.011136),  Route carried "on" structure: Interstate 15,  Year Built: 2020,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 114,229 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 142,786 (year 2040),  Design Load: HL 93,  Features Intersected: 200 S
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 538.654,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.5m (70.5ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.0m (78.7ft),  Curb-To-Curb Width: 21.5m (70.5ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F 33,  Location: 300 NO.ST.in CLEARFIELD (Lat: 41.118075,  Lng: -112.034917),  Route carried "under" structure: City street ,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 50 (year 2020),  Features Intersected: CITY STREET AND UPRR,  Facility Carried by Structure: SR-107
Minimum Vertical Clearance: 4.25m (13.94ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 1D 719,  Location: HAFB Intch (650 North) (Lat: 41.122819,  Lng: -112.022678),  Route carried "under" structure: State highway 103,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 16,363 (year 2020),  Truck Traffic: 19%,  Features Intersected: SR-103 W. GATE HILL AFB,  Facility Carried by Structure: I-15 (SR-15) NBL
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 0.225,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 23.9m (78.4ft)

Find on map >>   Show street view

Structure Number: 1D 747,  Location: 800 E. 200 SO. CLEARFIELD (Lat: 41.110178,  Lng: -112.009953),  Route carried "under" structure: City street 1480,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 459 (year 2020),  Features Intersected: 200 SOUTH STREET,  Facility Carried by Structure: I-15 (SR-15) NBL
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 15.3m (50.2ft)

Find on map >>   Show street view

Structure Number: 1F 63,  Location: CLEARFIELD INT. (700 SO) (Lat: 41.102542,  Lng: -112.002950),  Route carried "under" structure: State highway 193,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 2,197 (year 2020),  Truck Traffic: 10%,  Features Intersected: SR-193 700 SO.CLEARFIELD,  Facility Carried by Structure: I-15 (SR-15) NBL
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 0.901,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.7m (58.1ft)

Find on map >>   Show street view

Structure Number: 3D 719,  Location: HAFB Intch (650 North) (Lat: 41.124267,  Lng: -112.024433),  Route carried "under" structure: State highway 103,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 16,363 (year 2020),  Truck Traffic: 19%,  Features Intersected: SR-103 W. GATE HILL AFB,  Facility Carried by Structure: I-15 (SR-15) SBL
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 0.177,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 23.9m (78.4ft)

Find on map >>   Show street view

Structure Number: 3F 63,  Location: CLEARFIELD INT (700 SO) (Lat: 41.104436,  Lng: -112.004997),  Route carried "under" structure: State highway 193,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 2,197 (year 2020),  Truck Traffic: 10%,  Features Intersected: SR-193,700 SO.CLEARFIELD,  Facility Carried by Structure: I-15 (SR-15) SBL
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.933,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.7m (58.1ft)

Find on map >>   Show street view

Structure Number: 3F 901,  Location: I-15 over 200 S (Lat: 41.110931,  Lng: -112.011136),  Route carried "under" structure: City street 1480,  Year Built: 2020,  Structure Length: 0. m,  Average Daily Traffic: 459 (year 2020),  Features Intersected: 200 S,  Facility Carried by Structure: I-15 SB
Minimum Vertical Clearance: 4.74m (15.55ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.0m (78.7ft)

Discuss Clearfield, Utah (UT) on our hugely popular Utah forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.