Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Clio, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 22Number of bridges
  • 177ft / 53.7mTotal length
  • $205,000Total costs
  • 492,358Total average daily traffic
  • 59,285Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Clio
  • No street view available for this location

New bridges in Clio, MI - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 11920-1929
  • 31930-1939
  • 101950-1959
  • 21970-1979
  • 11980-1989
  • 21990-1999
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Clio, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 01980-1989
  • 41990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Clio, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 12.5%Very good
  • 18.8%Good
  • 37.5%Satisfactory
  • 31.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 31.3%Very good
  • 12.5%Good
  • 25.0%Satisfactory
  • 25.0%Fair
  • 6.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 31.3%Very good
  • 31.3%Satisfactory
  • 31.3%Fair
  • 6.3%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.7%Very good
  • 46.2%Good
  • 30.8%Satisfactory
  • 7.7%Fair
  • 7.7%Poor
Find on map >>   Show street view

Structure Number: 262,  Location: APPROX 1/4MI S OF 128TH A (Lat: 42.613753,  Lng: -85.692292),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 0.69m (2.26ft),  Average Daily Traffic: 70 (year 2002),  Truck Traffic: 7%,  Average Future Daily Traffic: 140 (year 2022),  Design Load: H 20,  Features Intersected: MILLER CREEK,  Facility Carried by Structure: 15TH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.534,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.9m (9.5ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 21.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 13.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 2489,  Location: 5.0 MI S OF SAGINAW COL (Lat: 43.151297,  Lng: -83.763308),  Route carried "on" structure: Interstate 75,  Year Built: 1958,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 4.47m (14.67ft),  Average Daily Traffic: 35,031 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 38,951 (year 2018),  Design Load: HS 20,  Features Intersected: BRENT RUN CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 37.023,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 149,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 32.4m (106.3ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.3m (50.2ft),  Curb-To-Curb Width: 24.9m (81.7ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 249,  Location: 5.0 MI S OF SAGINAW COL (Lat: 43.151403,  Lng: -83.763647),  Route carried "on" structure: Interstate 75,  Year Built: 1958,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 4.47m (14.67ft),  Average Daily Traffic: 35,031 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 38,951 (year 2018),  Design Load: HS 20,  Features Intersected: BRENT RUN CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 36.833,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 150,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 32.4m (106.3ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.3m (50.2ft),  Curb-To-Curb Width: 21.1m (69.2ft),  Out-to-Out Width: 22.0m (72.2ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2492,  Location: 0.4 MI N OF M-57 (Lat: 43.183175,  Lng: -83.768658),  Route carried "on" structure: Interstate 75,  Year Built: 1958,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 28,043 (year 2007),  Truck Traffic: 15%,  Average Future Daily Traffic: 65,715 (year 2018),  Design Load: HS 20,  Features Intersected: PINE RUN CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 40.412,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 150,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 17.9m (58.7ft),  Skew: 13 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 24.1m (79.1ft),  Out-to-Out Width: 24.6m (80.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 47.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 251,  Location: 2.1 MI S OF M-57 (Lat: 43.148314,  Lng: -83.763347),  Route carried "on" structure: County highway 2584,  Year Built: 1958,  Status: Open,  Structure Length: 7.56m (24.80ft),  Average Daily Traffic: 2,145 (year 1996),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,900 (year 2016),  Design Load: H 15,  Features Intersected: I-75,  Facility Carried by Structure: DODGE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.991,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.2m (69.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 62.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 2511,  Location: 1.0 MI S OF M-57 (Lat: 43.162800,  Lng: -83.768017),  Route carried "on" structure: County highway ,  Year Built: 1958,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 6.68m (21.92ft),  Average Daily Traffic: 2,400 (year 1996),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,300 (year 2016),  Design Load: H 15,  Features Intersected: I-75,  Facility Carried by Structure: WILSON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.757,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.8m (71.5ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 45.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 2512,  Location: AT M-57 (Lat: 43.177592,  Lng: -83.768614),  Route carried "on" structure: State highway 57,  Year Built: 1998,  Status: Open,  Structure Length: 7.84m (25.72ft),  Average Daily Traffic: 20,432 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 17,773 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: I-75
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.173,  Lanes on structure: 5,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 23.4m (76.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.2m (95.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 24.6m (80.7ft),  Out-to-Out Width: 28.3m (92.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2514,  Location: 2.0 MI N OF M-57 (Lat: 43.206297,  Lng: -83.768867),  Route carried "on" structure: County highway ,  Year Built: 1959,  Status: Open,  Structure Length: 6.28m (20.60ft),  Average Daily Traffic: 1,000 (year 1996),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,800 (year 2016),  Design Load: H 15,  Features Intersected: I-75,  Facility Carried by Structure: LAKE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.695,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 50.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 262,  Location: IN CLIO (Lat: 43.177422,  Lng: -83.732333),  Route carried "on" structure: State highway 57,  Year Built: 1915,  Year Reconstructed: 1960,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 14,723 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,768 (year 2018),  Design Load: H 15,  Features Intersected: PINE RUN CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.123,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 149,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.91m (2.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $45,000,  Roadway Improvement Cost: $3,000,  Total Project Cost: $35,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2811,  Location: 2250 FT EAST OF CLIO ROAD (Lat: 43.155669,  Lng: -83.725617),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1973,  Status: Posted for load,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 174 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 314 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: BENJAMIN RUN CREEK,  Facility Carried by Structure: BINGHAM ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.710,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 14.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 10.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2812,  Location: 1350 FT EAST OF CLIO RD (Lat: 43.162836,  Lng: -83.729367),  Route carried "on" structure: Alternate County highway ,  Year Built: 2008,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 3,762 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,795 (year 2038),  Design Load: HS 20,  Features Intersected: BENJAMIN RUN,  Facility Carried by Structure: WILSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.902,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 64.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2813,  Location: 1750 FT WEST OF LINDEN RD (Lat: 43.191839,  Lng: -83.780647),  Route carried "on" structure: County highway ,  Year Built: 2016,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 1,631 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,946 (year 2029),  Design Load: H 20,  Features Intersected: PINE RUN,  Facility Carried by Structure: FARRAND ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.829,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2815,  Location: INT OF WILSON & WEBSTER (Lat: 43.162792,  Lng: -83.793536),  Route carried "on" structure: County highway ,  Year Built: 1938,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 1.23m (4.04ft),  Average Daily Traffic: 1,795 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,242 (year 2029),  Design Load: Greater than HL93,  Features Intersected: BRENT RUN,  Facility Carried by Structure: WILSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.683,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 76.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 59.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2817,  Location: 2500 FT SOUTH OF WILSON (Lat: 43.155736,  Lng: -83.773956),  Route carried "on" structure: County highway ,  Year Built: 1931,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 4,149 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,493 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: BRENT RUN,  Facility Carried by Structure: LINDEN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 42.593,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Serious,  Channel: Poor,  Operating Rating: 34.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 1.77m (5.81ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $136,000,  Roadway Improvement Cost: $14,000,  Total Project Cost: $170,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2818,  Location: INTER OF LINDEN & FIELD (Lat: 43.184669,  Lng: -83.774367),  Route carried "on" structure: County highway ,  Year Built: 1929,  Status: Posted for load,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 5,320 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,609 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: PINE RUN,  Facility Carried by Structure: LINDEN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 45.807,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2819,  Location: 1700 FT NORTH OF VIENNA (Lat: 43.182364,  Lng: -83.754269),  Route carried "on" structure: County highway ,  Year Built: 1937,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 4,394 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,936 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: PINE RUN,  Facility Carried by Structure: JENNINGS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.768,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2821,  Location: IN CLIO (Lat: 43.180022,  Lng: -83.734614),  Route carried "on" structure: City street 2002,  Year Built: 1980,  Status: Posted for load,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 9,900 (year 1998),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,870 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: PINE RUN CREEK,  Facility Carried by Structure: MILL STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.724,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.2m (59.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 18.2m (59.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 251,  Location: 2.1 MI S OF M-57 (Lat: 43.148314,  Lng: -83.763347),  Route carried "under" structure: Interstate 75,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 70,062 (year 2007),  Truck Traffic: 12%,  Features Intersected: I-75,  Facility Carried by Structure: DODGE RD
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 36.691,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.2m (69.6ft)

Find on map >>   Show street view

Structure Number: 2511,  Location: 1.0 MI S OF M-57 (Lat: 43.162800,  Lng: -83.768017),  Route carried "under" structure: Interstate 75,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 70,062 (year 2007),  Truck Traffic: 12%,  Features Intersected: I-75,  Facility Carried by Structure: WILSON RD
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 38.362,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.8m (71.5ft)

Find on map >>   Show street view

Structure Number: 2512,  Location: AT M-57 (Lat: 43.177592,  Lng: -83.768614),  Route carried "under" structure: Interstate 75,  Year Built: 1998,  Structure Length: 0. m,  Average Daily Traffic: 70,062 (year 2007),  Truck Traffic: 15%,  Features Intersected: I-75,  Facility Carried by Structure: M-57 (VIENNA RD)
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 40.008,  Lanes on structure: 5,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 29.2m (95.8ft)

Find on map >>   Show street view

Structure Number: 2513,  Location: 1.0 MI N OF M-57 (Lat: 43.191797,  Lng: -83.768775),  Route carried "under" structure: Interstate 75,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 56,086 (year 2007),  Truck Traffic: 15%,  Features Intersected: I-75,  Facility Carried by Structure: FARRAND RD
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 41.585,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 2514,  Location: 2.0 MI N OF M-57 (Lat: 43.206297,  Lng: -83.768867),  Route carried "under" structure: Interstate 75,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 56,086 (year 2007),  Truck Traffic: 15%,  Features Intersected: I-75,  Facility Carried by Structure: LAKE RD
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 43.195,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Discuss Clio, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.