Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Dakota Ridge, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 138ft / 42.0mTotal length
  • $2,130,000Total costs
  • 209,239Total average daily traffic
  • 5,622Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Dakota Ridge
  • No street view available for this location

New bridges in Dakota Ridge, CO - historical statistics
  • New bridges - historical statistics
  • 21960-1969
  • 31980-1989
  • 41990-1999
  • 62000-2009
  • 32010-2019
Average Bridge Daily Traffic in Dakota Ridge, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 22.2%Very good
  • 44.4%Good
  • 22.2%Satisfactory
  • 11.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 44.4%Good
  • 44.4%Satisfactory
  • 11.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.1%Very good
  • 44.4%Good
  • 44.4%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 18.2%Very good
  • 45.5%Good
  • 36.4%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 66.7%Good
  • 33.3%Satisfactory
Find on map >>   Show street view

Structure Number: F-16-NL,  Location: 1.2 MI S OF JCT SH 285 (Lat: 39.624397,  Lng: -105.153458),  Route carried "on" structure: State highway 470A,  Year Built: 1990,  Status: Open,  Structure Length: 5.88m (19.29ft),  Average Daily Traffic: 31,500 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 41,580 (year 2040),  Design Load: HS 20,  Features Intersected: BELLEVIEW AVE,  Facility Carried by Structure: SH 470 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.103,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 59.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-NM,  Location: 1.2 MI S OF JCT SH 285 (Lat: 39.624397,  Lng: -105.153769),  Route carried "on" structure: State highway 470A,  Year Built: 1990,  Status: Open,  Structure Length: 5.88m (19.29ft),  Average Daily Traffic: 31,500 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 41,580 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BELLEVIEW AVE,  Facility Carried by Structure: SH 470 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.088,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-NN,  Location: 1.1 MI S OF BELLEVIEW (Lat: 39.609508,  Lng: -105.152753),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 6.79m (22.28ft),  Average Daily Traffic: 11,524 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 13,253 (year 2041),  Design Load: HS 20,  Features Intersected: SH 470 ML,  Facility Carried by Structure: BOWLES AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.040,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.0m (111.5ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 0.0m,  Curb-To-Curb Width: 28.7m (94.2ft),  Out-to-Out Width: 32.6m (107.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 64.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: F-16-PI,  Location: 0.5 MI S. OF BOWLES (Lat: 39.602008,  Lng: -105.153733),  Route carried "on" structure: State highway 470A,  Year Built: 1988,  Status: Open,  Structure Length: 8.24m (27.03ft),  Average Daily Traffic: 29,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 39,150 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DUTCH CREEK,  Facility Carried by Structure: SH 470 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.705,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.8m (133.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-SG,  Location: 0.9 MI E OF JCT SH 8 (Lat: 39.628789,  Lng: -105.178700),  Route carried "on" structure: US 285D,  Year Built: 2008,  Status: Open,  Structure Length: 2.30m (7.55ft),  Average Daily Traffic: 39,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 50,700 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: COUNTY ROAD 60,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 140.410,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.7m (81.0ft),  Skew: 32 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 24.7m (81.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 78.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.82m (12.53ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $1,420,000,  Roadway Improvement Cost: $142,000,  Total Project Cost: $2,130,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-18-01,  Location: 1.0 MI E OF CO 8 (Lat: 39.630781,  Lng: -105.174903),  Route carried "on" structure: County highway ,  Year Built: 2018,  Status: Open,  Structure Length: 3.23m (10.60ft),  Average Daily Traffic: 220 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 253 (year 2041),  Design Load: HL 93,  Features Intersected: TURKEY CREEK,  Facility Carried by Structure: HOGBACK ROAD
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 0.708,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: G-18-79,  Location: .5 MI S OF QUINCY (Lat: 39.631233,  Lng: -105.142872),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 0.74m (2.43ft),  Average Daily Traffic: 1,665 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,914 (year 2041),  Design Load: HS 20,  Features Intersected: WEAVER CREEK,  Facility Carried by Structure: YOUNGFIELD ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.473,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Out-to-Out Width: 27.7m (90.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2019
Find on map >>   Show street view

Structure Number: G-18-9,  Location: 0.6 mi S. of Quincy Ave (Lat: 39.627778,  Lng: -105.155139),  Route carried "on" structure: County highway ,  Year Built: 2012,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 1,067 (year 2021),  Average Future Daily Traffic: 1,227 (year 2041),  Design Load: HS 20,  Features Intersected: WEAVER CREEK,  Facility Carried by Structure: ELDRIDGE STREET
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.473,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: G-18-91,  Location: 0.3 mi N. of Bellview Ave (Lat: 39.626183,  Lng: -105.156456),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 9,838 (year 2021),  Average Future Daily Traffic: 11,314 (year 2041),  Design Load: HS 20,  Features Intersected: WEAVER CREEK,  Facility Carried by Structure: W. QUINCY AVENUE
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.295,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 19.1m (62.7ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Out-to-Out Width: 36.0m (118.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: H-18-11,  Location: 0.1 MI SOUTH OF QUINCY (Lat: 39.637081,  Lng: -105.128631),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 16,238 (year 2021),  Average Future Daily Traffic: 18,674 (year 2041),  Design Load: HS 20,  Features Intersected: WEAVER CREEK,  Facility Carried by Structure: SIMMS STREET
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 6.536,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 28.1m (92.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: H-18-115,  Location: 0.15 MI E OF SIMMS AVE (Lat: 39.638658,  Lng: -105.125567),  Route carried "on" structure: County highway ,  Year Built: 2012,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 7,474 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 8,595 (year 2041),  Features Intersected: WEAVER CREEK,  Facility Carried by Structure: QUINCY AVENUE
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 4.405,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.2m (43.3ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.9m (16.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.7m (8.9ft),  Out-to-Out Width: 39.9m (130.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: H-18-94,  Location: E OF APTS SW KIPLING ST (Lat: 39.651814,  Lng: -105.115561),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 2.75m (9.02ft),  Average Daily Traffic: 9 (year 2021),  Average Future Daily Traffic: 10 (year 2041),  Design Load: HS 20,  Features Intersected: WEAVER CREEK,  Facility Carried by Structure: EMERG. ACCESS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.0m (85.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: H-18-95,  Location: 0.2 MI SOUTH OF BELLEVIEW (Lat: 39.620339,  Lng: -105.128708),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 13,889 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 15,973 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: NORTH COON CREEK,  Facility Carried by Structure: SIMMS STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.661,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 28.5m (93.5ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 42.6m (139.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: H-18-96,  Location: .1 MI W OF KIPLING (Lat: 39.633422,  Lng: -105.111381),  Route carried "on" structure: County highway ,  Year Built: 1963,  Status: Open,  Structure Length: 1.11m (3.64ft),  Average Daily Traffic: 3,162 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,636 (year 2041),  Design Load: HS 20,  Features Intersected: HARRIMAN CANAL,  Facility Carried by Structure: LAKEHURST WAY
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.168,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H-18-97,  Location: .1 MI W OF KIPLING (Lat: 39.634319,  Lng: -105.112194),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Open,  Structure Length: 1.14m (3.74ft),  Average Daily Traffic: 447 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 514 (year 2041),  Design Load: HS 20,  Features Intersected: HARRIMAN CANAL,  Facility Carried by Structure: SURREY DRIVE
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.441,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.5m (34.4ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.2m (36.7ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 10.6m (34.8ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: F-16-NE,  Location: 0.5 MI SE OF SH470+US285 (Lat: 39.631825,  Lng: -105.160664),  Route carried "under" structure: State highway 470A,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 7,906 (year 2016),  Truck Traffic: 6%,  Features Intersected: SH 470 ML,  Facility Carried by Structure: QUINCY AVE
Minimum Vertical Clearance: 7.19m (23.59ft),  Kilometerpoint: 1.072,  Lanes on structure: 4,  Lanes under structure: 7,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 46.0m (150.9ft)

Find on map >>   Show street view

Structure Number: F-16-NN,  Location: 1.1 MI S OF BELLEVIEW (Lat: 39.609508,  Lng: -105.152753),  Route carried "under" structure: State highway 470A,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 4,800 (year 2018),  Truck Traffic: 6%,  Features Intersected: SH 470 ML,  Facility Carried by Structure: BOWLES AVE
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 0.042,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 34.0m (111.5ft)

Find on map >>   Show street view

Structure Number: F-16-SG,  Location: 0.9 MI E OF JCT SH 8 (Lat: 39.628789,  Lng: -105.178700),  Route carried "under" structure: County highway ,  Year Built: 2008,  Structure Length: 0. m,  Features Intersected: COUNTY ROAD 60,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 16.93m (55.54ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 22.2m (72.8ft)

Discuss Dakota Ridge, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.