Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Durand, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 29Number of bridges
  • 246ft / 75.2mTotal length
  • 576,819Total average daily traffic
  • 98,135Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Durand
  • No street view available for this location

New bridges in Durand, MI - historical statistics
  • New bridges - historical statistics
  • 141960-1969
  • 21970-1979
  • 31980-1989
  • 81990-1999
  • 22010-2019
Reconstructed bridges in Durand, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Durand, MI
Average Bridge Truck Traffic in Durand, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 4.8%Very good
  • 52.4%Good
  • 38.1%Satisfactory
  • 4.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.3%Very good
  • 52.4%Good
  • 28.6%Satisfactory
  • 4.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 19.0%Very good
  • 61.9%Good
  • 14.3%Satisfactory
  • 4.8%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 5.6%Very good
  • 44.4%Good
  • 33.3%Satisfactory
  • 11.1%Fair
  • 5.6%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Good
  • 33.3%Satisfactory
  • 33.3%Fair
Find on map >>   Show street view

Structure Number: 1829,  Location: 1.6 MI E OF US-127 BR (Lat: 43.001353,  Lng: -84.519058),  Route carried "on" structure: US 127,  Year Built: 1993,  Status: Open,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 10,100 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,163 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: M-21
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.078,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 319,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 93.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2355,  Location: 8 MILES E OF OLIVET (Lat: 42.454886,  Lng: -84.777264),  Route carried "on" structure: County highway 2361,  Year Built: 1966,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 953 (year 2009),  Average Future Daily Traffic: 840 (year 2013),  Design Load: HS 20+Mod,  Features Intersected: BATTLE CREEK RIVER,  Facility Carried by Structure: NARROW LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.829,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 3195,  Location: SEC 18 ELBA TWP (Lat: 43.164931,  Lng: -84.477406),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 112 (year 2004),  Average Future Daily Traffic: 139 (year 2024),  Design Load: HS 20,  Features Intersected: WOLF & BEAR CREEK DRAIN,  Facility Carried by Structure: ARNOLD ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.406,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 5134,  Location: 300 FT W OF WHITNEYVILLE (Lat: 42.870472,  Lng: -85.460144),  Route carried "on" structure: County highway ,  Year Built: 1971,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 142 (year 2004),  Average Future Daily Traffic: 240 (year 2024),  Design Load: HS 20+Mod,  Features Intersected: UNNAMED,  Facility Carried by Structure: 52ND STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.713,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 9736,  Location: 0.3 MI NE OF M-71 (Lat: 42.928894,  Lng: -83.994878),  Route carried "on" structure: Interstate 69,  Year Built: 1961,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 192,000 (year 2011),  Truck Traffic: 17%,  Average Future Daily Traffic: 212,000 (year 2031),  Design Load: HS 25 or greater,  Features Intersected: HOLLY DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 34.058,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.3m (56.8ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 83.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 9737,  Location: 0.3 MI NE OF M-71 (Lat: 42.929000,  Lng: -83.995297),  Route carried "on" structure: Interstate 69,  Year Built: 1961,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 192,000 (year 2011),  Truck Traffic: 17%,  Average Future Daily Traffic: 212,000 (year 2031),  Design Load: HS 25 or greater,  Features Intersected: HOLLY DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 34.016,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.6m (57.7ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 9738,  Location: 2.7 MI SW OF GENESEE COL (Lat: 42.955989,  Lng: -83.969208),  Route carried "on" structure: Interstate 69,  Year Built: 1961,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 14,378 (year 2007),  Truck Traffic: 20%,  Average Future Daily Traffic: 15,340 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: WEBB DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 37.732,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 9739,  Location: 2.7 MI SW OF GENESEE COL (Lat: 42.955967,  Lng: -83.969675),  Route carried "on" structure: Interstate 69,  Year Built: 1961,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 14,378 (year 2007),  Truck Traffic: 20%,  Average Future Daily Traffic: 15,340 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: WEBB DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 37.679,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 9742,  Location: 0.6 MI SW OF M-71 (Lat: 42.924239,  Lng: -84.011483),  Route carried "on" structure: Interstate 69,  Year Built: 1961,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 9.18m (30.12ft),  Average Daily Traffic: 13,840 (year 2007),  Truck Traffic: 22%,  Average Future Daily Traffic: 19,072 (year 2018),  Design Load: HS 20,  Features Intersected: CN RR & REED RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 32.605,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 80.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9752,  Location: @ M-71 (Lat: 42.927011,  Lng: -84.000750),  Route carried "on" structure: State highway 71,  Year Built: 2011,  Status: Open,  Structure Length: 8.96m (29.40ft),  Average Daily Traffic: 8,100 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,900 (year 2031),  Design Load: HL 93,  Features Intersected: I-69
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.150,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 47.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9753,  Location: 0.8 MI NE OF M-71 (Lat: 42.934553,  Lng: -83.988567),  Route carried "on" structure: County highway 7687,  Year Built: 1961,  Status: Open,  Structure Length: 10.89m (35.73ft),  Average Daily Traffic: 2,882 (year 2011),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,184 (year 2031),  Design Load: H 15,  Features Intersected: I-69,  Facility Carried by Structure: DURAND RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.237,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 30.4m (99.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9754,  Location: 2.7 MI SW OF GENESEE COL (Lat: 42.950953,  Lng: -83.973733),  Route carried "on" structure: County highway ,  Year Built: 1961,  Status: Open,  Structure Length: 7.67m (25.16ft),  Average Daily Traffic: 250 (year 1988),  Average Future Daily Traffic: 220 (year 1977),  Design Load: H 20,  Features Intersected: I-69,  Facility Carried by Structure: GOODALL RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.889,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 9769,  Location: 0.3 MI NW OF I-69 (Lat: 42.928978,  Lng: -84.002586),  Route carried "on" structure: State highway 71,  Year Built: 1961,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 1.81m (5.94ft),  Average Daily Traffic: 8,100 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,900 (year 2031),  Design Load: HS 20+Mod,  Features Intersected: HOLLY DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.415,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.2m (56.4ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 80.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 9784,  Location: 1 MILE NW OF DURAND (Lat: 42.923814,  Lng: -84.010672),  Route carried "on" structure: County highway 7628,  Year Built: 1992,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 3,723 (year 2011),  Truck Traffic: 20%,  Average Future Daily Traffic: 5,532 (year 2031),  Design Load: HS 20,  Features Intersected: GTW RR & GARRISON RD,  Facility Carried by Structure: LANSING ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 20.087,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.5m (73.8ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9785,  Location: 0.5 MI NE OF DURAND (Lat: 42.925469,  Lng: -83.975775),  Route carried "on" structure: County highway 7628,  Year Built: 1988,  Status: Posted for load,  Structure Length: 1.61m (5.28ft),  Average Daily Traffic: 6,858 (year 2011),  Truck Traffic: 20%,  Average Future Daily Traffic: 10,190 (year 2031),  Design Load: HS 20,  Features Intersected: HOLLY DRAIN,  Facility Carried by Structure: LANSING ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.974,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9818,  Location: 1 MILE NORTH OF DURAND (Lat: 42.927347,  Lng: -83.988297),  Route carried "on" structure: County highway 7687,  Year Built: 1967,  Status: Open,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 7,643 (year 2011),  Truck Traffic: 15%,  Average Future Daily Traffic: 11,313 (year 2031),  Design Load: HS 20,  Features Intersected: HOLLY DRAIN,  Facility Carried by Structure: DURAND ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.437,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 68.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 9819,  Location: 2.5 MILES NORTH OF DURAND (Lat: 42.958561,  Lng: -83.987111),  Route carried "on" structure: County highway 7687,  Year Built: 1965,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 3,203 (year 2011),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,760 (year 2031),  Design Load: HS 20,  Features Intersected: WEBB CREEK,  Facility Carried by Structure: DURAND ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.928,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Poor,  Operating Rating: 76.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 9871,  Location: 0.5 MI N 1 MI E OF DURAND (Lat: 42.918397,  Lng: -83.965983),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 363 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 539 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: THREE MILE CREEK,  Facility Carried by Structure: MONROE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.885,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.7m (54.8ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 19 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 9872,  Location: 1.5 MI NE OF DURAND (Lat: 42.918589,  Lng: -83.957572),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 155 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 284 (year 2018),  Design Load: HS 20,  Features Intersected: MIKAN DRAIN,  Facility Carried by Structure: MONROE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.572,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 61.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9873,  Location: 2 MI S .6 MI W OF LENNON (Lat: 42.940611,  Lng: -83.943103),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 128 (year 1996),  Truck Traffic: 5%,  Average Future Daily Traffic: 231 (year 2016),  Design Load: HS 20,  Features Intersected: WEBB CREEK,  Facility Carried by Structure: BENNINGTON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.198,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.7m (58.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Channel: Fair,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9877,  Location: 1.2 MI SE OF VERNON (Lat: 42.929169,  Lng: -84.008150),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 179 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 218 (year 2040),  Design Load: HS 20,  Features Intersected: HOLLY DRAIN,  Facility Carried by Structure: REED RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.321,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.9m (29.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 67.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 9878,  Location: 1 MI E 0.4 MI N OF DURAND (Lat: 42.916964,  Lng: -83.968267),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 1,126 (year 1998),  Average Future Daily Traffic: 2,030 (year 2018),  Design Load: HS 20,  Features Intersected: THREE MILE CREEK,  Facility Carried by Structure: NEW LOTHROP RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.480,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.9m (35.8ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 80.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 61.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 9879,  Location: 1 MI E 0.7 MI N OF DURAND (Lat: 42.921164,  Lng: -83.968414),  Route carried "on" structure: County highway ,  Year Built: 1971,  Status: Posted for load,  Structure Length: 1.67m (5.48ft),  Average Daily Traffic: 1,850 (year 1992),  Truck Traffic: 15%,  Average Future Daily Traffic: 3,330 (year 2012),  Design Load: HS 20,  Features Intersected: HOLLY DRAIN,  Facility Carried by Structure: NEW LOTHROP RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.947,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 33.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 988,  Location: 3.5 MI S OF LENNON (Lat: 42.932575,  Lng: -83.929275),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 424 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 517 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: JONES CREEK,  Facility Carried by Structure: COUNTY LINE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.005,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 9742,  Location: 0.6 MI SW OF M-71 (Lat: 42.924239,  Lng: -84.011483),  Route carried "under" structure: County highway ,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 30 (year 1999),  Features Intersected: CN RR & REED RD,  Facility Carried by Structure: I-69 EB
Minimum Vertical Clearance: 5.94m (19.49ft),  Kilometerpoint: 8.388,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.8m (51.8ft)

Find on map >>   Show street view

Structure Number: 9752,  Location: @ M-71 (Lat: 42.927011,  Lng: -84.000750),  Route carried "under" structure: Interstate 69,  Year Built: 2011,  Structure Length: 0. m,  Average Daily Traffic: 36,360 (year 2011),  Truck Traffic: 19%,  Features Intersected: I-69,  Facility Carried by Structure: M-71
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 33.532,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>   Show street view

Structure Number: 9753,  Location: 0.8 MI NE OF M-71 (Lat: 42.934553,  Lng: -83.988567),  Route carried "under" structure: Interstate 69,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 28,756 (year 2007),  Truck Traffic: 20%,  Features Intersected: I-69,  Facility Carried by Structure: DURAND RD
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 34.876,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.4m (99.7ft)

Find on map >>   Show street view

Structure Number: 9754,  Location: 2.7 MI SW OF GENESEE COL (Lat: 42.950953,  Lng: -83.973733),  Route carried "under" structure: Interstate 69,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 28,756 (year 2007),  Truck Traffic: 20%,  Features Intersected: I-69,  Facility Carried by Structure: GOODALL RD
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 37.063,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 9784,  Location: 1 MILE NW OF DURAND (Lat: 42.923814,  Lng: -84.010672),  Route carried "under" structure: County highway ,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 30 (year 1999),  Features Intersected: GTW RR & GARRISON RD,  Facility Carried by Structure: LANSING ROAD
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 8.306,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.5m (73.8ft)

Discuss Durand, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.