Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Estes Park, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 36Number of bridges
  • 190ft / 58.5mTotal length
  • $684,000Total costs
  • 89,884Total average daily traffic
  • 5,494Total average daily truck traffic
  • 111,007Total future (year 2028) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Estes Park
  • No street view available for this location

New bridges in Estes Park, CO - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 21940-1949
  • 11950-1959
  • 21960-1969
  • 111970-1979
  • 111980-1989
  • 12000-2009
  • 72010-2019
Reconstructed bridges in Estes Park, CO - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 61990-1999
  • 22000-2009
Average Bridge Daily Traffic in Estes Park, CO
Average Bridge Truck Traffic in Estes Park, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 6.7%Very good
  • 36.7%Good
  • 46.7%Satisfactory
  • 6.7%Fair
  • 3.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 3.3%Very good
  • 33.3%Good
  • 46.7%Satisfactory
  • 16.7%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 3.3%Very good
  • 20.0%Good
  • 53.3%Satisfactory
  • 23.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 44.4%Good
  • 16.7%Satisfactory
  • 5.6%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 83.3%Good
  • 16.7%Fair
Find on map >>   Show street view

Structure Number: 1520001S,  Location: 0.1 MILES WEST OF BEAR LA (Lat: 40.353861,  Lng: -105.584056),  Route carried "on" structure: ServiceFederal lands road ,  Year Built: 1982,  Status: Open,  Structure Length: 1.26m (4.13ft),  Average Daily Traffic: 50 (year 2008),  Truck Traffic: 1%,  Average Future Daily Traffic: 100 (year 2028),  Design Load: HS 20,  Features Intersected: BIG THOMPSON RIVER,  Facility Carried by Structure: KALEY CABIN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.113,  Lanes on structure: 1,  Owner: National Park Service,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $15,000,  Roadway Improvement Cost: $2,000,  Total Project Cost: $23,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 1520002P,  Location: 1.9 MILES SOUTH OF BEAVER (Lat: 40.350806,  Lng: -105.578028),  Route carried "on" structure: Federal lands road 12,  Year Built: 1960,  Status: Open,  Structure Length: 9.14m (29.99ft),  Average Daily Traffic: 2,500 (year 2008),  Truck Traffic: 1%,  Average Future Daily Traffic: 3,500 (year 2028),  Design Load: HS 20,  Features Intersected: BIG THOMPSON RIVER,  Facility Carried by Structure: BEAR LAKE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.170,  Lanes on structure: 2,  Owner: National Park Service,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 24.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 14.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Critical Feature Inspection Date: October 2020,  Bridge Improvement Cost: $95,000,  Roadway Improvement Cost: $10,000,  Total Project Cost: $143,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1520005P,  Location: 2.0 MILES WEST OF FALL RI (Lat: 40.404861,  Lng: -105.625583),  Route carried "on" structure: Federal lands road ,  Year Built: 1983,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 3,310 (year 2008),  Truck Traffic: 1%,  Average Future Daily Traffic: 5,000 (year 2028),  Design Load: HS 20,  Features Intersected: FALL RIVER,  Facility Carried by Structure: U.S. ROUTE 34
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.734,  Lanes on structure: 2,  Owner: National Park Service,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $36,000,  Roadway Improvement Cost: $4,000,  Total Project Cost: $54,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 1520006P,  Location: 0.2 MILES FROM FALL RIVER (Lat: 40.401944,  Lng: -105.596556),  Route carried "on" structure: Federal lands road ,  Year Built: 1983,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 300 (year 2008),  Truck Traffic: 1%,  Average Future Daily Traffic: 500 (year 2028),  Design Load: HS 20,  Features Intersected: FALL RIVER,  Facility Carried by Structure: ASPENGLEN CAMPGROU
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.531,  Lanes on structure: 2,  Owner: National Park Service,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.2m (7.2ft),  Curb-To-Curb Width: 7.7m (25.3ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $55,000,  Roadway Improvement Cost: $6,000,  Total Project Cost: $83,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 1520018P,  Location: ENTRANCE TO GLACIER BASIN (Lat: 40.330306,  Lng: -105.599028),  Route carried "on" structure: Federal lands road ,  Year Built: 1982,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 80 (year 2008),  Truck Traffic: 1%,  Average Future Daily Traffic: 150 (year 2028),  Design Load: HS 20,  Features Intersected: GLACIER CREEK,  Facility Carried by Structure: GLACIER BASIN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.080,  Lanes on structure: 2,  Owner: National Park Service,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 6.4m (21.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $11,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $17,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: C-14-A,  Location: IN ESTES PARK (Lat: 40.377800,  Lng: -105.515800),  Route carried "on" structure: US 36B,  Year Built: 1951,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 2.56m (8.40ft),  Average Daily Traffic: 16,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 17,920 (year 2040),  Design Load: H 15,  Features Intersected: BIG THOMPSON RIVER,  Facility Carried by Structure: US 36 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.106,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: C-14-C,  Location: 0.3 MI S. OF SH34 IN ESTE (Lat: 40.375556,  Lng: -105.523611),  Route carried "on" structure: US 36A,  Year Built: 2018,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 10,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 11,400 (year 2040),  Design Load: HL 93,  Features Intersected: FALL RIVER,  Facility Carried by Structure: US 36 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.797,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 10.4m (34.1ft),  Right: 6.2m (20.3ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 31.9m (104.7ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: C-14-K,  Location: W SIDE OF ESTES PARK (Lat: 40.376100,  Lng: -105.526100),  Route carried "on" structure: Business US 34C,  Year Built: 1960,  Status: Open,  Structure Length: 0.69m (2.26ft),  Average Daily Traffic: 4,094 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 5,360 (year 2031),  Features Intersected: FALL RIVER,  Facility Carried by Structure: US 34 BUSINESS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.811,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft),  Curb or Sidewalk Widths: Left: 4.0m (13.1ft),  Right: 6.4m (21.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.69m (2.26ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $116,000,  Roadway Improvement Cost: $12,000,  Total Project Cost: $128,000 ( Estimate for 2017)
Find on map >>   Show street view

Structure Number: C-14-O,  Location: US 34 BUS. IN ESTES PARK (Lat: 40.377569,  Lng: -105.532283),  Route carried "on" structure: Business US 34C,  Year Built: 1948,  Status: Open,  Structure Length: 1.33m (4.36ft),  Average Daily Traffic: 2,200 (year 2011),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,706 (year 2031),  Design Load: H 20,  Features Intersected: FALL RIVER,  Facility Carried by Structure: US 34 BUSINESS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.225,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: C-15-AL,  Location: 2 MI E OF ESTES PARK (Lat: 40.389700,  Lng: -105.464200),  Route carried "on" structure: US 34A,  Year Built: 2010,  Status: Open,  Structure Length: 3.49m (11.45ft),  Average Daily Traffic: 5,800 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,250 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: BIG THOMPSON RIVER,  Facility Carried by Structure: US 34 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 106.284,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C-15-AM,  Location: 1.5 MI E OF ESTES PARK (Lat: 40.380544,  Lng: -105.472942),  Route carried "on" structure: US 34A,  Year Built: 2010,  Status: Open,  Structure Length: 3.49m (11.45ft),  Average Daily Traffic: 5,800 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,250 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: BIG THOMPSON RIVER,  Facility Carried by Structure: US 34 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 104.852,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C-15-M,  Location: E EDGE OF ESTES PARK (Lat: 40.378200,  Lng: -105.488100),  Route carried "on" structure: US 34A,  Year Built: 1937,  Status: Open,  Structure Length: 1.32m (4.33ft),  Average Daily Traffic: 6,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,680 (year 2040),  Design Load: H 15,  Features Intersected: DEVILS GULCH,  Facility Carried by Structure: US 34 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 103.164,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 38.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-CRAGS-THOM,  Location: 50 Ft N of W Riverside (Lat: 40.371583,  Lng: -105.523639),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 3,968 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 4,960 (year 2041),  Design Load: HS 20,  Features Intersected: Big Thompson River,  Facility Carried by Structure: Crags Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.622,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 15 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-DAVIDDR-FALL,  Location: 80 Ft W of US Hwy 34 (Lat: 40.394444,  Lng: -105.564500),  Route carried "on" structure: City street ,  Year Built: 1974,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 302 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 378 (year 2041),  Design Load: HS 20,  Features Intersected: Fall River,  Facility Carried by Structure: David Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.9m (29.2ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-EASTRVR-THOM,  Location: 0.1 Mi S of Elkhorn Ave. (Lat: 40.375772,  Lng: -105.521111),  Route carried "on" structure: City street ,  Year Built: 1979,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 6,670 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,338 (year 2041),  Design Load: HS 20,  Features Intersected: Big Thompson River,  Facility Carried by Structure: East Riverside Dr
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.359,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.5m (21.3ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 75.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-FALLRCT-FALL,  Location: 100 Ft S of US Hwy 34 (Lat: 40.389639,  Lng: -105.561583),  Route carried "on" structure: City street ,  Year Built: 1974,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 347 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 434 (year 2041),  Design Load: HS 20,  Features Intersected: Fall River,  Facility Carried by Structure: Fall River Court
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.028,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-FALLRLN-FALL,  Location: 250 Ft S of W Elkhorn (Lat: 40.382000,  Lng: -105.540778),  Route carried "on" structure: City street ,  Year Built: 1983,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 268 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 335 (year 2041),  Design Load: HS 20,  Features Intersected: Fall River,  Facility Carried by Structure: Fall River Lane
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.652,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 15 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-FHACHRD-FALL,  Location: 0.2 Mi W of US Hwy 34 (Lat: 40.397222,  Lng: -105.568722),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 0.95m (3.12ft),  Average Daily Traffic: 613 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 766 (year 2041),  Design Load: HS 20,  Features Intersected: Fall River,  Facility Carried by Structure: Fish Hatchery Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.338,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 44.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-FHATRD2-FALL,  Location: 0.9 Mi S of US Hwy 34 (Lat: 40.399556,  Lng: -105.582917),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 0.93m (3.05ft),  Average Daily Traffic: 153 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 191 (year 2041),  Design Load: HS 20,  Features Intersected: Fall River,  Facility Carried by Structure: Fish Hatchery Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.491,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.4m (27.6ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Very good,  Operating Rating: 50.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-HOMESTD-FALL,  Location: 200 Ft SW of US Hwy 34 (Lat: 40.384639,  Lng: -105.557194),  Route carried "on" structure: City street ,  Year Built: 1983,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 222 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 278 (year 2041),  Design Load: HS 20,  Features Intersected: Fall River,  Facility Carried by Structure: Homestead Lane
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.050,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.9m (32.5ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 0.0m,  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-IVY-THOM,  Location: 95 Ft W of E Riverside Av (Lat: 40.374417,  Lng: -105.522444),  Route carried "on" structure: City street ,  Year Built: 1976,  Status: Open,  Structure Length: 1.11m (3.64ft),  Average Daily Traffic: 1,499 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 1,874 (year 2041),  Design Load: HS 20,  Features Intersected: Big Thompson River,  Facility Carried by Structure: Ivy Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.027,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.7m (31.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 43.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-RANGE-FALL-R,  Location: 0.5 Mi S of Hwy 34 (Lat: 40.378028,  Lng: -105.536556),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 417 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 521 (year 2041),  Design Load: HS 20,  Features Intersected: Fall River,  Facility Carried by Structure: Old Ranger Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.625,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-RCKWLL-THOM,  Location: 60 Ft W of East River (Lat: 40.375222,  Lng: -105.522000),  Route carried "on" structure: City street ,  Year Built: 1971,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 4,134 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 5,168 (year 2041),  Features Intersected: Big Thompson River,  Facility Carried by Structure: Rockwell Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.129,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: EP-SPRC-FALL,  Location: 100 Ft N of Elkhorn Ave (Lat: 40.376667,  Lng: -105.527306),  Route carried "on" structure: City street ,  Year Built: 1978,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 0.74m (2.43ft),  Average Daily Traffic: 958 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 1,198 (year 2041),  Design Load: HS 20,  Features Intersected: Fall River,  Facility Carried by Structure: Spruce Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.021,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Very good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: LR63-0.5-S36-A,  Location: 0.5 Mi N of US Hwy 36 (Lat: 40.374472,  Lng: -105.481500),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 2.00m (6.56ft),  Average Daily Traffic: 5,062 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,328 (year 2041),  Design Load: HS 20,  Features Intersected: Big Thompson River,  Facility Carried by Structure: County Road 63
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.824,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.7m (61.4ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 41.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: LR63-1.4-63A-B,  Location: 3 Mi. S. of SH 36 (Lat: 40.335889,  Lng: -105.502111),  Route carried "on" structure: County highway ,  Year Built: 2017,  Status: Open,  Structure Length: 0.65m (2.13ft),  Average Daily Traffic: 1,124 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 1,405 (year 2041),  Features Intersected: Fish Creek,  Facility Carried by Structure: County Road 63
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.116,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.5m (21.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 24.1m (79.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: LR67-0.2-67E-A,  Location: 0.2 Mi E of Co Rd 67E (Lat: 40.362556,  Lng: -105.543500),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 4,541 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 5,676 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: Big Thompson River,  Facility Carried by Structure: County Road 67
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.307,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 79.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: LR69B-S0.1-S66A,  Location: 0.1 Mi S of End of SH S66 (Lat: 40.348694,  Lng: -105.568556),  Route carried "on" structure: County highway ,  Year Built: 1940,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 3,310 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 4,138 (year 2041),  Design Load: HS 20,  Features Intersected: Big Thompson River,  Facility Carried by Structure: County Road 69B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.199,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.6m (51.2ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: LRB19-2358BTC,  Location: 15 Ft S of US Hwy 34 (Lat: 40.392556,  Lng: -105.436306),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 30 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 38 (year 2041),  Design Load: H 15,  Features Intersected: Big Thompson River,  Facility Carried by Structure: Big Pine Lane
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 109.247,  Lanes on structure: 1,  Owner: County Highway Agency,  Maintenance Responsibility: Local Agency,  Approaching Roadway Width: 3.0m (9.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 3.3m (10.8ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Length Of Structure Improvement: 1.22m (4.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $61,000,  Roadway Improvement Cost: $6,000,  Total Project Cost: $67,000 ( Estimate for 2019),  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: LRB20-2382BTC,  Location: 40 Ft S of US Hwy 34 (Lat: 40.393444,  Lng: -105.440167),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 18 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 23 (year 2041),  Design Load: H 15,  Features Intersected: Big Thompson River,  Facility Carried by Structure: Rocky River Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 108.846,  Lanes on structure: 1,  Owner: County Highway Agency,  Maintenance Responsibility: Local Agency,  Approaching Roadway Width: 3.0m (9.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.5m (47.6ft),  Curb-To-Curb Width: 3.3m (10.8ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 1.52m (4.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $76,000,  Roadway Improvement Cost: $8,000,  Total Project Cost: $84,000 ( Estimate for 2019),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: LRB22-2563BTC,  Location: 25 Ft N of US Hwy 34 (Lat: 40.388750,  Lng: -105.466417),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 28 (year 2021),  Average Future Daily Traffic: 35 (year 2041),  Design Load: H 15,  Features Intersected: Big Thompson River,  Facility Carried by Structure: Elk Island Way
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 106.061,  Lanes on structure: 1,  Owner: County Highway Agency,  Maintenance Responsibility: Local Agency,  Approaching Roadway Width: 2.7m (8.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 3.3m (10.8ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 1.52m (4.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $77,000,  Roadway Improvement Cost: $8,000,  Total Project Cost: $85,000 ( Estimate for 2018),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: LRBRTHDDALELN1,  Location: 10 Ft S of US Hwy 34 (Lat: 40.385153,  Lng: -105.469242),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 36 (year 2021),  Average Future Daily Traffic: 45 (year 2041),  Features Intersected: Big Thompson River,  Facility Carried by Structure: Berthoud Dale Ln.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: County Highway Agency,  Maintenance Responsibility: Local Agency,  Approaching Roadway Width: 3.0m (9.8ft),  Skew: 1 degrees,  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.1m (39.7ft),  Curb-To-Curb Width: 3.5m (11.5ft),  Out-to-Out Width: 3.8m (12.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 9.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 9.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: LRROCKCANYON1,  Location: 10 Ft W of US Hwy 34 (Lat: 40.383508,  Lng: -105.470292),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 1.50m (4.92ft),  Average Daily Traffic: 24 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 30 (year 2041),  Features Intersected: Big Thompson River,  Facility Carried by Structure: Rock Canyon Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Base Highway Network: Yes,  Owner: County Highway Agency,  Maintenance Responsibility: Local Agency,  Approaching Roadway Width: 3.0m (9.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.8m (48.6ft),  Curb-To-Curb Width: 3.3m (10.8ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: No rating analysis performed,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: LRWESTCRKRD1,  Location: 0.3 MI W of CR 43 (Lat: 40.442039,  Lng: -105.460803),  Route carried "on" structure: County highway ,  Year Built: 2016,  Status: Open,  Structure Length: 1.05m (3.44ft),  Average Daily Traffic: 5 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 6 (year 2041),  Design Load: HL 93,  Features Intersected: West Creek,  Facility Carried by Structure: West Creek Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft),  Curb-To-Curb Width: 5.4m (17.7ft),  Out-to-Out Width: 6.2m (20.3ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: LRWESTCRKRD2,  Location: 0.2 MI W OF CR 43 (Lat: 40.441333,  Lng: -105.460647),  Route carried "on" structure: County highway ,  Year Built: 2017,  Status: Open,  Structure Length: 1.08m (3.54ft),  Average Daily Traffic: 8 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 10 (year 2041),  Design Load: HL 93,  Features Intersected: West Creek,  Facility Carried by Structure: West Creek Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: LRWESTCRKRD3,  Location: 0.1 MI W OF CR 43 (Lat: 40.441894,  Lng: -105.459261),  Route carried "on" structure: County highway ,  Year Built: 2016,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 13 (year 2021),  Average Future Daily Traffic: 16 (year 2041),  Design Load: HL 93,  Features Intersected: West Creek,  Facility Carried by Structure: West Creek Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Discuss Estes Park, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.