Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Fairview Heights, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 17Number of bridges
  • 102ft / 31.4mTotal length
  • 1,231,950Total average daily traffic
  • 41,610Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Fairview Heights
  • No street view available for this location

New bridges in Fairview Heights, IL - historical statistics
  • New bridges - historical statistics
  • 11960-1969
  • 81970-1979
  • 31980-1989
  • 52000-2009
Reconstructed bridges in Fairview Heights, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Fairview Heights, IL
Average Bridge Truck Traffic in Fairview Heights, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 14.3%Excellent
  • 28.6%Very good
  • 28.6%Good
  • 14.3%Satisfactory
  • 14.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.3%Excellent
  • 14.3%Very good
  • 42.9%Good
  • 14.3%Satisfactory
  • 14.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Excellent
  • 14.3%Very good
  • 42.9%Good
  • 14.3%Satisfactory
  • 14.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 14.3%Very good
  • 42.9%Good
  • 42.9%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 75.0%Very good
  • 25.0%Satisfactory
Find on map >>   Show street view

Structure Number: 820122,  Location: 300 FT. S. BUNKUM RD (Lat: 38.619569,  Lng: -90.039733),  Route carried "on" structure: County highway ,  Year Built: 1965,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 75 (year 2018),  Truck Traffic: 19%,  Average Future Daily Traffic: 105 (year 2032),  Features Intersected: CREEK,  Facility Carried by Structure: N 89TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.402,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Good,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 820175,  Location: 0.57 MI W OF ILL 159 (Lat: 38.599981,  Lng: -89.995339),  Route carried "on" structure: Other road ,  Year Built: 1970,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 7.52m (24.67ft),  Average Daily Traffic: 4,700 (year 2018),  Truck Traffic: 11%,  Average Future Daily Traffic: 5,544 (year 2032),  Design Load: HS 20,  Features Intersected: FAI 64,  Facility Carried by Structure: RUBY LANE/ FAU 932
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.080,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 820176,  Location: 0.57 MI E RUBY LANE (Lat: 38.599031,  Lng: -89.985103),  Route carried "on" structure: State highway 159,  Year Built: 1970,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 7.07m (23.20ft),  Average Daily Traffic: 35,800 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 37,028 (year 2032),  Design Load: HS 20,  Features Intersected: FAI 64
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 43.821,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.4m (83.3ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 28.3m (92.8ft),  Curb-To-Curb Width: 32.1m (105.3ft),  Out-to-Out Width: 33.1m (108.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 52.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 820208,  Location: N of I-64 (Lat: 38.602731,  Lng: -89.985150),  Route carried "on" structure: State highway 159,  Year Built: 1973,  Status: Open,  Structure Length: 4.50m (14.76ft),  Average Daily Traffic: 21,000 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 21,025 (year 2032),  Design Load: HS 20,  Features Intersected: CSX RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 44.207,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.5m (57.4ft),  Curb-To-Curb Width: 21.5m (70.5ft),  Out-to-Out Width: 28.0m (91.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 820308,  Location: 1.01MI E IL 159 (Lat: 38.598739,  Lng: -89.966289),  Route carried "on" structure: Interstate 64,  Year Built: 2007,  Status: Open,  Structure Length: 4.65m (15.26ft),  Average Daily Traffic: 39,400 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 36,662 (year 2032),  Design Load: HS 20,  Features Intersected: OLD COLLINSVILLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.130,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.7m (58.1ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 82.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 822022,  Location: .14 E IL 159 (Lat: 38.592689,  Lng: -89.980428),  Route carried "on" structure: Other road ,  Year Built: 1985,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 18,600 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 21,129 (year 2032),  Design Load: HS 20,  Features Intersected: OGLES CREEK,  Facility Carried by Structure: FAU 9166 LINCOLN H
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.713,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 822024,  Location: .1 MI E ILL 161 (Lat: 38.584278,  Lng: -90.038342),  Route carried "on" structure: Other road ,  Year Built: 1977,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 2,400 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,504 (year 2032),  Design Load: HS 20,  Features Intersected: HOLLOW CREEK,  Facility Carried by Structure: OLD LINCOLN TRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.963,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.0m (26.2ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 82204,  Location: .06 SO. ST. CLAIR AV (Lat: 38.595061,  Lng: -90.045850),  Route carried "on" structure: State highway 161,  Year Built: 2000,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 11,700 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,958 (year 2032),  Design Load: HS 20,  Features Intersected: Trib to SHOENBRGR CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.805,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 823068,  Location: 2.25 MI N ILL 161 (Lat: 38.580061,  Lng: -90.003731),  Route carried "on" structure: Other road ,  Year Built: 1981,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 8,550 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 8,786 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB SCHOENBERGER CR,  Facility Carried by Structure: UNION HILLRD/FAU91
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.545,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 826501,  Location: .32 MI N RTE 50 (Lat: 38.596794,  Lng: -89.966250),  Route carried "on" structure: Other road ,  Year Built: 1980,  Status: Open,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 8,700 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,891 (year 2032),  Design Load: HS 20,  Features Intersected: OGLE CREEK,  Facility Carried by Structure: OLD COLV RD MS6000
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.996,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 48.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 826513,  Location: 1.2 MI N OF BUNKUM R (Lat: 38.612878,  Lng: -90.001519),  Route carried "on" structure: Other road ,  Year Built: 2009,  Status: Open,  Structure Length: 1.14m (3.74ft),  Average Daily Traffic: 525 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 680 (year 2032),  Design Load: HS 20,  Features Intersected: CREEK,  Facility Carried by Structure: PLSNT RDG RD/FAU91
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.851,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 820174,  Location: 1.99 MI E ILL 157 (Lat: 38.600769,  Lng: -90.013281),  Route carried "under" structure: Interstate 64,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 488,400 (year 2021),  Truck Traffic: 2%,  Features Intersected: FAI 64,  Facility Carried by Structure: BUNKUM RD/ FAU 916
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 17.042,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.4m (112.9ft)

Find on map >>   Show street view

Structure Number: 820175,  Location: 0.57 MI W OF ILL 159 (Lat: 38.599981,  Lng: -89.995339),  Route carried "under" structure: Interstate 64,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 488,400 (year 2021),  Truck Traffic: 2%,  Features Intersected: FAI 64,  Facility Carried by Structure: RUBY LANE/ FAU 932
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 18.620,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.8m (87.9ft)

Find on map >>   Show street view

Structure Number: 820176,  Location: 0.57 MI E RUBY LANE (Lat: 38.599283,  Lng: -89.984575),  Route carried "under" structure: Other road ,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 7,500 (year 2018),  Truck Traffic: 6%,  Features Intersected: FAI 64,  Facility Carried by Structure: ILL 159
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.386,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 820176,  Location: 0.57 MI E RUBY LANE (Lat: 38.599014,  Lng: -89.984900),  Route carried "under" structure: Interstate 64,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 78,800 (year 2021),  Truck Traffic: 14%,  Features Intersected: FAI 64,  Facility Carried by Structure: ILL 159
Minimum Vertical Clearance: 5.99m (19.65ft),  Kilometerpoint: 19.537,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 820308,  Location: 1.01MI E IL 159 (Lat: 38.598525,  Lng: -89.966283),  Route carried "under" structure: Other road ,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 8,700 (year 2018),  Truck Traffic: 3%,  Features Intersected: OLD COLLINSVILLE RD,  Facility Carried by Structure: FAI 64 EB
Minimum Vertical Clearance: 4.83m (15.85ft),  Kilometerpoint: 1.819,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.7m (58.1ft)

Find on map >>   Show street view

Structure Number: 820309,  Location: 1.02MI E OF ILL 159 (Lat: 38.598739,  Lng: -89.966289),  Route carried "under" structure: Other road ,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 8,700 (year 2018),  Truck Traffic: 3%,  Features Intersected: OLD COLLINSVILLE RD,  Facility Carried by Structure: FAI 64 WB
Minimum Vertical Clearance: 4.83m (15.85ft),  Kilometerpoint: 1.802,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.7m (58.1ft)

Discuss Fairview Heights, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.