Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Garnett, Kansas (KS)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 20Number of bridges
  • 292ft / 89.5mTotal length
  • $280,000Total costs
  • 22,683Total average daily traffic
  • 4,604Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Garnett
  • No street view available for this location

New bridges in Garnett, KS - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11920-1929
  • 21930-1939
  • 31950-1959
  • 11970-1979
  • 61980-1989
  • 31990-1999
  • 12000-2009
  • 22010-2019
Average Bridge Daily Traffic in Garnett, KS
Average Bridge Truck Traffic in Garnett, KS
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 37.5%Very good
  • 50.0%Good
  • 6.3%Satisfactory
  • 6.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 50.0%Very good
  • 37.5%Good
  • 6.3%Satisfactory
  • 6.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 43.8%Very good
  • 31.3%Good
  • 18.8%Satisfactory
  • 6.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 16.7%Very good
  • 44.4%Good
  • 33.3%Satisfactory
  • 5.6%Fair
Find on map >>   Show street view

Structure Number: 20008,  Location: 1.1 W OF 1650-MEADE (Lat: 38.262542,  Lng: -95.305339),  Route carried "on" structure: County highway 10,  Year Built: 1954,  Status: Posted for load,  Structure Length: 6.72m (22.05ft),  Average Daily Traffic: 840 (year 2014),  Truck Traffic: 30%,  Average Future Daily Traffic: 1,008 (year 2042),  Design Load: H 15,  Features Intersected: CEDAR CREEK,  Facility Carried by Structure: 1650 RD L.4-16.3
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 24.951,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20033,  Location: 0.2 N OF OHIO-2200 (Lat: 38.349217,  Lng: -95.203500),  Route carried "on" structure: County highway 1390,  Year Built: 1974,  Status: Open,  Structure Length: 10.58m (34.71ft),  Average Daily Traffic: 76 (year 2014),  Average Future Daily Traffic: 126 (year 2042),  Design Load: HS 15,  Features Intersected: POTTAWATOMIE CREEK,  Facility Carried by Structure: Ohio R.0-22.2
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 9.817,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 63.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 2006,  Location: 0.8 E OF 1750 - OSAGE (Lat: 38.280747,  Lng: -95.180256),  Route carried "on" structure: County highway 15,  Year Built: 2012,  Status: Open,  Structure Length: 4.96m (16.27ft),  Average Daily Traffic: 568 (year 2014),  Truck Traffic: 30%,  Average Future Daily Traffic: 682 (year 2042),  Design Load: HL 93,  Features Intersected: S Fork Pottawatomie Crk,  Facility Carried by Structure: 1750 Rd. S.3-17.5
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.5m (24.6ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 33.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 880004,  Location: 6.0S.W. OF SATANTA (Lat: 37.361736,  Lng: -101.050275),  Route carried "on" structure: County highway 1562,  Year Built: 1985,  Status: Open,  Structure Length: 0.87m (2.85ft),  Average Daily Traffic: 85 (year 2008),  Average Future Daily Traffic: 85 (year 2038),  Design Load: H 20,  Features Intersected: TRIB. TO CIMARRON RIVER
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Other Special Inspection Date: January 2001
Find on map >>   Show street view

Structure Number: 21039605365,  Location: 0.5 E 1750-MARSHALL (Lat: 38.282283,  Lng: -95.293825),  Route carried "on" structure: County highway ,  Year Built: 1908,  Year Reconstructed: 1981,  Status: Open,  Structure Length: 4.52m (14.83ft),  Average Daily Traffic: 25 (year 2014),  Truck Traffic: 30%,  Average Future Daily Traffic: 30 (year 2042),  Design Load: H 20,  Features Intersected: CEDAR CREEK,  Facility Carried by Structure: 1750 Rd M.1-17.5
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 47.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 21041005281,  Location: 3.0E 2.6N OF GLENLOCK (Lat: 38.345944,  Lng: -95.285917),  Route carried "on" structure: County highway ,  Year Built: 2004,  Status: Open,  Structure Length: 8.49m (27.85ft),  Average Daily Traffic: 50 (year 2014),  Truck Traffic: 30%,  Average Future Daily Traffic: 60 (year 2042),  Design Load: HL 93,  Features Intersected: POTTAWATOMIE CREEK,  Facility Carried by Structure: Meade M.5-21.9
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.2m (92.5ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 51.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 21041505321,  Location: 1.0 N OF MISSOURI-1900 (Lat: 38.317944,  Lng: -95.276892),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 5.05m (16.57ft),  Average Daily Traffic: 20 (year 2014),  Truck Traffic: 30%,  Average Future Daily Traffic: 25 (year 2042),  Design Load: HS 20,  Features Intersected: CEDAR CREEK,  Facility Carried by Structure: Missouri N.0-20.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 21047005405,  Location: 1.0 S OF NEBRASKA-HWY 169 (Lat: 38.250625,  Lng: -95.239569),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 50 (year 2014),  Average Future Daily Traffic: 60 (year 2042),  Design Load: HS 20,  Features Intersected: TRIB. S. FORK POTT. CK.,  Facility Carried by Structure: Nebraska P.0-15.6
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 59.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 21047405288,  Location: 0.2 N NEVADA-2100 (Lat: 38.334156,  Lng: -95.223906),  Route carried "on" structure: County highway ,  Year Built: 1920,  Status: Posted for load,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 20 (year 2014),  Average Future Daily Traffic: 25 (year 2042),  Features Intersected: TRIB. TO CEDAR CREEK,  Facility Carried by Structure: Nevada P.8-21.2
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Masonry,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 5.8m (19.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 21.6 metric tons,  Method Used To Determine Operating Rating: No rating analysis performed,  Inventory Rating: 15.4 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 1.95m (6.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Bridge Improvement Cost: $170,000,  Roadway Improvement Cost: $110,000,  Total Project Cost: $280,000 ( Estimate for 2015),  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 21047505403,  Location: 1.3 S NEOSHO-HWY 169 (Lat: 38.255567,  Lng: -95.231136),  Route carried "on" structure: County highway ,  Year Built: 1950,  Status: Posted for load,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 20 (year 2014),  Average Future Daily Traffic: 25 (year 2042),  Features Intersected: TRIB. S. FK. POTT. CK.,  Facility Carried by Structure: Neosho P.5-15.7
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 10.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 6.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 2105150538,  Location: 0.5 E 1700-OSAGE (Lat: 38.273539,  Lng: -95.184789),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 20 (year 2014),  Truck Traffic: 30%,  Average Future Daily Traffic: 30 (year 2042),  Design Load: H 20,  Features Intersected: S. FK. POTTAWATOMIE CK.,  Facility Carried by Structure: 1700 Rd R.9-17.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 41.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 21053105347,  Location: 1.0 E OF 1830-OSAGE (Lat: 38.291603,  Lng: -95.174658),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 4.65m (15.26ft),  Average Daily Traffic: 25 (year 2014),  Average Future Daily Traffic: 30 (year 2042),  Design Load: HS 20,  Features Intersected: POTTAWATOMIE CREEK,  Facility Carried by Structure: 1830 Rd S.5-18.3
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 67.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 21053405346,  Location: 1.5 E 1830-OSAGE (Lat: 38.293639,  Lng: -95.166958),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 25 (year 2014),  Average Future Daily Traffic: 30 (year 2042),  Design Load: HS 20,  Features Intersected: TRIB. POTTAWATOMIE CREEK,  Facility Carried by Structure: 1830 Rd T.0-18.4
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 2105350532,  Location: 0.5 E 2000-SCOTT (Lat: 38.317036,  Lng: -95.166200),  Route carried "on" structure: County highway 212,  Year Built: 1981,  Status: Open,  Structure Length: 4.35m (14.27ft),  Average Daily Traffic: 40 (year 2014),  Truck Traffic: 30%,  Average Future Daily Traffic: 50 (year 2042),  Design Load: H 20,  Features Intersected: SO. FK. POTTAWATOMIE CK.,  Facility Carried by Structure: 2000 Rd S.9-20.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.9m (22.6ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.5m (54.1ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 43.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 999903100020341,  Location: 18.14 MI SE COFFEY COLN (Lat: 38.298333,  Lng: -95.287500),  Route carried "on" structure: State highway 31,  Year Built: 1987,  Status: Open,  Structure Length: 6.04m (19.82ft),  Average Daily Traffic: 710 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 956 (year 2041),  Design Load: HS 20,  Features Intersected: CEDAR CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 28.736,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 19.80m (64.96ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999905900020311,  Location: 2.37 MI N-NJCT K31 (Lat: 38.322222,  Lng: -95.250556),  Route carried "on" structure: US 59,  Year Built: 1957,  Year Reconstructed: 1978,  Status: Open,  Structure Length: 2.85m (9.35ft),  Average Daily Traffic: 4,436 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 6,093 (year 2041),  Design Load: HS 20,  Features Intersected: ABANDONED ACCESS ROAD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 38.339,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 37.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 9.36m (30.71ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 999905900020351,  Location: 3.61 MI N SJCT US169 (Lat: 38.249444,  Lng: -95.248333),  Route carried "on" structure: US 59,  Year Built: 1987,  Status: Open,  Structure Length: 4.95m (16.24ft),  Average Daily Traffic: 4,855 (year 2020),  Truck Traffic: 31%,  Average Future Daily Traffic: 7,214 (year 2041),  Design Load: HS 20,  Features Intersected: SOUTH POTTAWATOMIE CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 30.201,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 16.25m (53.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999905900020421,  Location: 3.17 MI N NJCT K31 (Lat: 38.333611,  Lng: -95.248611),  Route carried "on" structure: US 59,  Year Built: 2016,  Status: Open,  Structure Length: 12.33m (40.45ft),  Average Daily Traffic: 4,436 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 6,093 (year 2041),  Design Load: HL 93,  Features Intersected: POTTAWATOMIE CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 39.630,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.8m (101.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 40.46m (132.74ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999905900020044,  Location: 0.33 MI N NJCT US169 (Lat: 38.260833,  Lng: -95.248889),  Route carried "under" structure: US 59,  Year Built: 1938,  Structure Length: 0. m,  Average Daily Traffic: 3,191 (year 2020),  Truck Traffic: 21%,  Features Intersected: US 59 HWY,  Facility Carried by Structure: ATSF RAILROAD
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 31.496,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 21.8m (71.5ft)

Find on map >>   Show street view

Structure Number: 999905900020054,  Location: 1.24 MI N NJCT US169 (Lat: 38.273889,  Lng: -95.249167),  Route carried "under" structure: US 59,  Year Built: 1939,  Structure Length: 0. m,  Average Daily Traffic: 3,191 (year 2020),  Truck Traffic: 21%,  Features Intersected: US 59 HWY,  Facility Carried by Structure: UP RAILROAD
Minimum Vertical Clearance: 4.74m (15.55ft),  Kilometerpoint: 32.961,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 11.3m (37.1ft)