Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Harper Woods, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 20Number of bridges
  • 121ft / 37.2mTotal length
  • 1,623,716Total average daily traffic
  • 96,744Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Harper Woods
  • No street view available for this location

New bridges in Harper Woods, MI - historical statistics
  • New bridges - historical statistics
  • 161950-1959
  • 41960-1969
Reconstructed bridges in Harper Woods, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 41990-1999
  • 22000-2009
Average Bridge Daily Traffic in Harper Woods, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 12.5%Very good
  • 37.5%Good
  • 37.5%Satisfactory
  • 12.5%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 12.5%Very good
  • 37.5%Good
  • 25.0%Satisfactory
  • 12.5%Fair
  • 12.5%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 62.5%Good
  • 25.0%Satisfactory
  • 12.5%Fair
Find on map >>   Show street view

Structure Number: 1124,  Location: SHERWOOD TWP SEC 15-16 (Lat: 42.033800,  Lng: -85.234800),  Route carried "on" structure: County highway 1209,  Year Built: 1953,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 700 (year 2004),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,000 (year 2024),  Features Intersected: UNNAMED CREEK,  Facility Carried by Structure: OLD M-78 HWY
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.363,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.8m (38.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 61.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 11263,  Location: IN HARPER WOODS (Lat: 42.429267,  Lng: -82.925092),  Route carried "on" structure: City street ,  Year Built: 1959,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 4.78m (15.68ft),  Average Daily Traffic: 990 (year 2007),  Average Future Daily Traffic: 1,089 (year 2022),  Design Load: HS 20+Mod,  Features Intersected: I-94,  Facility Carried by Structure: WOODSIDE AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.050,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.7m (54.8ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Satisfactory,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 11264,  Location: IN HARPER WOODS (Lat: 42.433094,  Lng: -82.922733),  Route carried "on" structure: City street ,  Year Built: 1959,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 4.90m (16.08ft),  Average Daily Traffic: 1,320 (year 1988),  Average Future Daily Traffic: 1,518 (year 2008),  Design Load: HS 20+Mod,  Features Intersected: I-94,  Facility Carried by Structure: ALLARD AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.234,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.7m (54.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 11265,  Location: IN HARPER WOODS (Lat: 42.440433,  Lng: -82.919328),  Route carried "on" structure: City street ,  Year Built: 1959,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 3.23m (10.60ft),  Average Daily Traffic: 800 (year 2007),  Average Future Daily Traffic: 880 (year 2022),  Design Load: HS 20+Mod,  Features Intersected: I-94,  Facility Carried by Structure: LOCHMORE AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.050,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.1m (52.8ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 59.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11266,  Location: IN HARPER WOODS (Lat: 42.445803,  Lng: -82.917208),  Route carried "on" structure: State highway 102,  Year Built: 1959,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 15,461 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 16,661 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: I-94
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.572,  Lanes on structure: 5,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 25.1m (82.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Membrane: Other
Find on map >>   Show street view

Structure Number: 11267,  Location: IN HARPER WOODS (Lat: 42.446139,  Lng: -82.917086),  Route carried "on" structure: State highway 102,  Year Built: 1959,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 5.30m (17.39ft),  Average Daily Traffic: 15,461 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 16,661 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: I-94
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.537,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 11268,  Location: IN HARPER WOODS (Lat: 42.448369,  Lng: -82.916517),  Route carried "on" structure: City street ,  Year Built: 1960,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 6.76m (22.18ft),  Average Daily Traffic: 870 (year 2007),  Average Future Daily Traffic: 957 (year 2022),  Design Load: HS 20,  Features Intersected: I-94,  Facility Carried by Structure: HARPER AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.140,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 11269,  Location: AT MACOMB CO LINE (Lat: 42.450719,  Lng: -82.917183),  Route carried "on" structure: City street ,  Year Built: 1963,  Status: Open,  Structure Length: 5.88m (19.29ft),  Average Daily Traffic: 1,900 (year 2007),  Average Future Daily Traffic: 2,090 (year 2022),  Design Load: HS 20,  Features Intersected: I-94,  Facility Carried by Structure: 8 MI RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.685,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1124,  Location: IN HARPER WOODS (Lat: 42.427336,  Lng: -82.926433),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: KENOSHA AVE WALKOV
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 59.141,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 11241,  Location: IN HARPER WOODS (Lat: 42.431303,  Lng: -82.923661),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: WOODLAND AV WALKOV
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 59.636,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 23.1m (75.8ft)

Find on map >>   Show street view

Structure Number: 11242,  Location: IN HARPER WOODS (Lat: 42.436053,  Lng: -82.921264),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: WOODMONT WALKOVER
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 60.200,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 23.4m (76.8ft)

Find on map >>   Show street view

Structure Number: 11243,  Location: IN HARPER WOODS (Lat: 42.438214,  Lng: -82.920308),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: KENMORE AVE WALKOV
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 60.452,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 11244,  Location: IN HARPER WOODS (Lat: 42.443114,  Lng: -82.918158),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 137,828 (year 2007),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: BEAUFAIT AV WALKOV
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 61.024,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 11263,  Location: IN HARPER WOODS (Lat: 42.429267,  Lng: -82.925092),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: WOODSIDE AVE
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 59.382,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11264,  Location: IN HARPER WOODS (Lat: 42.433094,  Lng: -82.922733),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: ALLARD AVE
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 59.849,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11265,  Location: IN HARPER WOODS (Lat: 42.440433,  Lng: -82.919328),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: LOCHMORE AVE
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 60.711,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.1m (52.8ft)

Find on map >>   Show street view

Structure Number: 11266,  Location: IN HARPER WOODS (Lat: 42.445803,  Lng: -82.917208),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 137,828 (year 2007),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: M-102 EB
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 61.333,  Lanes on structure: 5,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 18.9m (62.0ft)

Find on map >>   Show street view

Structure Number: 11267,  Location: IN HARPER WOODS (Lat: 42.446139,  Lng: -82.917086),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 137,828 (year 2007),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: M-102 WB
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 61.371,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 11268,  Location: IN HARPER WOODS (Lat: 42.448369,  Lng: -82.916517),  Route carried "under" structure: Interstate 94,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 129,090 (year 2007),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: HARPER AVE
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 61.626,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 11269,  Location: AT MACOMB CO LINE (Lat: 42.450719,  Lng: -82.917183),  Route carried "under" structure: Interstate 94,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 129,090 (year 2007),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: 8 MI RD
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 61.894,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.6m (61.0ft)

Discuss Harper Woods, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.