Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Herrin, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 12Number of bridges
  • 125ft / 38.0mTotal length
  • 39,850Total average daily traffic
  • 2,634Total average daily truck traffic
  • 52,206Total future (year 2032) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Herrin
  • No street view available for this location

New bridges in Herrin, IL - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 21930-1939
  • 41980-1989
  • 21990-1999
  • 12000-2009
  • 22010-2019
Average Bridge Daily Traffic in Herrin, IL
Average Bridge Truck Traffic in Herrin, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 70.0%Very good
  • 10.0%Good
  • 20.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 70.0%Very good
  • 30.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 70.0%Very good
  • 20.0%Good
  • 10.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 8.3%Excellent
  • 58.3%Very good
  • 16.7%Good
  • 16.7%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Very good
  • 50.0%Good
Find on map >>   Show street view

Structure Number: 1000032,  Location: 0.1 MI S FRANKLIN CO (Lat: 37.860375,  Lng: -89.060039),  Route carried "on" structure: State highway 148,  Year Built: 1931,  Year Reconstructed: 1984,  Status: Open,  Structure Length: 13.72m (45.01ft),  Average Daily Traffic: 4,400 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,743 (year 2032),  Design Load: HS 20,  Features Intersected: BIG MUDDY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.094,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.9m (32.5ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 29.6m (97.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2021,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1000033,  Location: 1.1 MI S FRANKLIN CO (Lat: 37.847644,  Lng: -89.055150),  Route carried "on" structure: State highway 148,  Year Built: 1931,  Year Reconstructed: 1983,  Status: Open,  Structure Length: 5.43m (17.81ft),  Average Daily Traffic: 4,400 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,743 (year 2032),  Design Load: HS 20,  Features Intersected: POND CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.565,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.8m (71.5ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1000045,  Location: 1.1 MI W OF ILL 148 (Lat: 37.737725,  Lng: -89.033781),  Route carried "on" structure: County highway ,  Year Built: 1920,  Year Reconstructed: 1984,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 1,550 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,343 (year 2032),  Design Load: HS 20,  Features Intersected: PIGEON CREEK,  Facility Carried by Structure: SBI 13 (UNMARKED)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.005,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.9m (29.2ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 75.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 100008,  Location: 0.75M E HERRIN (Lat: 37.811225,  Lng: -89.004642),  Route carried "on" structure: Other road ,  Year Built: 2016,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 6,200 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,515 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB TO POND CREEK,  Facility Carried by Structure: HERRIN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.214,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 80.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1000081,  Location: 1.0M E HERRIN (Lat: 37.813572,  Lng: -88.998747),  Route carried "on" structure: Other road ,  Year Built: 2016,  Status: Open,  Structure Length: 3.97m (13.02ft),  Average Daily Traffic: 5,700 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 7,658 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB TO POND CREEK,  Facility Carried by Structure: HERRIN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.793,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.4m (40.7ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 76.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1002018,  Location: 0.5 MI E OF COLP (Lat: 37.811103,  Lng: -89.067750),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 5,700 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,801 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB TO HURRICANE CR,  Facility Carried by Structure: FAS 908 (CH 11)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.908,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 63.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2019
Find on map >>   Show street view

Structure Number: 1003116,  Location: 2 MILES E HERRIN (Lat: 37.795653,  Lng: -88.980708),  Route carried "on" structure: County highway ,  Year Built: 1983,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 2,150 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 3,143 (year 2032),  Design Load: HS 20,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: CH 4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.432,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1003124,  Location: 3.5 MI WEST MARION (Lat: 37.738008,  Lng: -89.030961),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 50 (year 2021),  Truck Traffic: 24%,  Average Future Daily Traffic: 29 (year 2032),  Design Load: HS 20,  Features Intersected: NAMELESS-STREAM,  Facility Carried by Structure: TR 202
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.612,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1003125,  Location: 1 MI. EAST OF HERRIN (Lat: 37.795642,  Lng: -88.992561),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 2,050 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,429 (year 2032),  Design Load: HS 20,  Features Intersected: UNNAMED STREAM,  Facility Carried by Structure: FAS 2903-CH 4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.370,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1003127,  Location: 2 MILES NEHERRIN (Lat: 37.839744,  Lng: -89.001042),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 275 (year 2021),  Truck Traffic: 27%,  Average Future Daily Traffic: 229 (year 2032),  Design Load: HS 20,  Features Intersected: LAKE CREEK,  Facility Carried by Structure: TR 23
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.901,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1003155,  Location: 1 MI NE OF HERRIN (Lat: 37.832517,  Lng: -89.004336),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 1.57m (5.15ft),  Average Daily Traffic: 375 (year 2021),  Truck Traffic: 27%,  Average Future Daily Traffic: 400 (year 2032),  Design Load: HS 20,  Features Intersected: POND CREEK TRIBUTARY,  Facility Carried by Structure: TR 43-CHITTYVILLE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.030,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1006021,  Location: 0.31 MI W OF IL 148 (Lat: 37.811000,  Lng: -89.032997),  Route carried "on" structure: Other road ,  Year Built: 1999,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 7,000 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,173 (year 2032),  Design Load: HS 20,  Features Intersected: 17TH ST DITCH,  Facility Carried by Structure: FAU 9588-HERRIN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.671,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2019
Discuss Herrin, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.