Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Hershey, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 28Number of bridges
  • 236ft / 72.4mTotal length
  • $5,247,000Total costs
  • 212,941Total average daily traffic
  • 12,441Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Hershey
  • No street view available for this location

New bridges in Hershey, PA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 21920-1929
  • 21940-1949
  • 71950-1959
  • 21960-1969
  • 11970-1979
  • 41980-1989
  • 21990-1999
  • 22000-2009
  • 52010-2019
Reconstructed bridges in Hershey, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11990-1999
  • 12000-2009
  • 22010-2019
Average Bridge Daily Traffic in Hershey, PA
Average Bridge Truck Traffic in Hershey, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.3%Very good
  • 47.4%Good
  • 42.1%Satisfactory
  • 5.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.8%Very good
  • 23.8%Good
  • 38.1%Satisfactory
  • 14.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Very good
  • 28.6%Good
  • 42.9%Satisfactory
  • 9.5%Fair
  • 4.8%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 10.5%Very good
  • 26.3%Good
  • 42.1%Satisfactory
  • 10.5%Fair
  • 10.5%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Good
  • 66.7%Fair
Find on map >>   Show street view

Structure Number: 14187,  Location: GRANTVILLE (Lat: 40.366183,  Lng: -76.660128),  Route carried "on" structure: US 22,  Year Built: 1944,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 8,137 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,754 (year 2032),  Design Load: HS 20,  Features Intersected: BOW CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.824,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 23 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.70m (5.58ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 14208,  Location: 0.5 Mi. N. of Hershey (Lat: 40.293303,  Lng: -76.674683),  Route carried "on" structure: State highway 39,  Year Built: 1967,  Status: Open,  Structure Length: 9.66m (31.69ft),  Average Daily Traffic: 13,461 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 21,085 (year 2032),  Design Load: HS 20,  Features Intersected: Swatara Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.549,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Poor,  Inventory Rating: 13.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 10.70m (35.10ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Underwater Inspection Date: July 2020,  Bridge Improvement Cost: $71,000,  Roadway Improvement Cost: $209,000,  Total Project Cost: $959,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 14209,  Location: HERSHEY (Lat: 40.283194,  Lng: -76.678778),  Route carried "on" structure: State highway 39,  Year Built: 1954,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 19,112 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 29,636 (year 2032),  Design Load: HS 20,  Features Intersected: SPRING CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.186,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 26.0m (85.3ft),  Out-to-Out Width: 27.1m (88.9ft)

Condition: Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.20m (7.22ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 14382,  Location: .5 MI. E. DEODATE (Lat: 40.215086,  Lng: -76.605597),  Route carried "on" structure: State highway 341,  Year Built: 1928,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 1,711 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,014 (year 2032),  Design Load: H 15,  Features Intersected: HOFFER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.069,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.1m (23.3ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Poor,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.30m (4.27ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $5,000,  Roadway Improvement Cost: $14,000,  Total Project Cost: $64,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 14384,  Location: 1 MI. E. HUMMELSTOWN (Lat: 40.266033,  Lng: -76.686972),  Route carried "on" structure: US 422,  Year Built: 1953,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 20,546 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 28,881 (year 2032),  Design Load: HS 20,  Features Intersected: US 322; SR 0322
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 9,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Skew: 34 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.4m (57.1ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Inventory Rating: 67.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.70m (18.70ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $70,000,  Roadway Improvement Cost: $207,000,  Total Project Cost: $947,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 14386,  Location: HERSHEY (Lat: 40.288883,  Lng: -76.641603),  Route carried "on" structure: US 422,  Year Built: 1928,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 15,014 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 19,012 (year 2032),  Features Intersected: SPRING CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.147,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.2m (46.6ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.50m (8.20ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $11,000,  Roadway Improvement Cost: $31,000,  Total Project Cost: $144,000
Find on map >>   Show street view

Structure Number: 14417,  Location: 2 MI. N.E. OF HERSHEY (Lat: 40.322264,  Lng: -76.629286),  Route carried "on" structure: State highway 743,  Year Built: 1976,  Status: Open,  Structure Length: 9.85m (32.32ft),  Average Daily Traffic: 9,864 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 15,928 (year 2032),  Design Load: HS 20,  Features Intersected: SWATARA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.934,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.1m (79.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 87.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 8.80m (28.87ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Galvanized Reinforcing
Find on map >>   Show street view

Structure Number: 14475,  Location: SAND BEACH (Lat: 40.306306,  Lng: -76.669364),  Route carried "on" structure: State highway ,  Year Built: 1941,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 1,534 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,921 (year 2032),  Design Load: HS 20,  Features Intersected: MANADA CREEK,  Facility Carried by Structure: SR 2010
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.698,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Fair,  Inventory Rating: 60.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 4.30m (14.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Bridge Improvement Cost: $90,000,  Roadway Improvement Cost: $265,000,  Total Project Cost: $1,214,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1448,  Location: HERSHEY (Lat: 40.281172,  Lng: -76.670581),  Route carried "on" structure: State highway ,  Year Built: 1983,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 3,060 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,366 (year 2032),  Design Load: HS 20,  Features Intersected: SPRING CREEK,  Facility Carried by Structure: SR 2011
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.671,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.30m (7.55ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 14481,  Location: .5 MI. N. OF HERSHEY (Lat: 40.299500,  Lng: -76.638497),  Route carried "on" structure: State highway ,  Year Built: 1917,  Status: Open,  Structure Length: 2.93m (9.61ft),  Average Daily Traffic: 2,149 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,160 (year 2032),  Design Load: H 15,  Features Intersected: NS RAILROAD,  Facility Carried by Structure: SR 2012
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Railroad,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.3m (92.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Poor,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Underclear: High priority of replacement,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 3.70m (12.14ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: August 2020,  Other Special Inspection Date: August 2021,  Bridge Improvement Cost: $91,000,  Roadway Improvement Cost: $267,000,  Total Project Cost: $1,225,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 14483,  Location: 1 MI. N. HERSHEY (Lat: 40.310664,  Lng: -76.665131),  Route carried "on" structure: State highway ,  Year Built: 1961,  Status: Open,  Structure Length: 9.81m (32.19ft),  Average Daily Traffic: 1,788 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,905 (year 2032),  Design Load: HS 20,  Features Intersected: SWATARA CREEK,  Facility Carried by Structure: SR 2015
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.979,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 10.90m (35.76ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2020,  Underwater Inspection Date: July 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 14499,  Location: 2.5 MI.N. HERSHEY (Lat: 40.326747,  Lng: -76.650833),  Route carried "on" structure: State highway ,  Year Built: 1989,  Status: Open,  Structure Length: 1.80m (5.91ft),  Average Daily Traffic: 494 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 563 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: BOW CREEK,  Facility Carried by Structure: SR 2022
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.801,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.4m (57.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 2.40m (7.87ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 14621,  Location: LONDONDERRY TOWNSHIP (Lat: 40.208917,  Lng: -76.658083),  Route carried "on" structure: State highway 341,  Year Built: 1950,  Status: Open,  Structure Length: 4.39m (14.40ft),  Average Daily Traffic: 3,093 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,561 (year 2030),  Design Load: HS 20,  Features Intersected: PA TPK (I-76)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.402,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Toll Authority,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.4m (139.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.30m (17.39ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Critical Feature Inspection Date: March 2021,  Bridge Improvement Cost: $13,000,  Roadway Improvement Cost: $39,000,  Total Project Cost: $178,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 14652,  Location: BOW CR/2.4S GRANTVILLE (Lat: 40.343950,  Lng: -76.650289),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 300 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 420 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: BOW CREEK,  Facility Carried by Structure: EARLYMILL RD. T431
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 2.30m (7.55ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 14653,  Location: 3 N HERSHY/EHANOVER/BOW (Lat: 40.335908,  Lng: -76.649094),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 175 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 245 (year 2041),  Features Intersected: BOW CREEK,  Facility Carried by Structure: SHADY LANE, T-461
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.20m (7.22ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 14701,  Location: 1.3 MI N OF S.R. 0039 (Lat: 40.309231,  Lng: -76.671675),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 1,000 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,200 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: MANADA CREEK,  Facility Carried by Structure: SHETLAND DR. T-425
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 2.60m (8.53ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $38,000,  Roadway Improvement Cost: $113,000,  Total Project Cost: $516,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 44475,  Location: 1 MI. E. HOCKERSVILLE (Lat: 40.261117,  Lng: -76.630950),  Route carried "on" structure: State highway ,  Year Built: 2007,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 1,655 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,762 (year 2032),  Design Load: HL 93,  Features Intersected: BRANCH OF SPRING CREEK,  Facility Carried by Structure: SR 2011 BACHMNVILL
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 4.706,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 47108,  Location: CROOKED HILL RD (Lat: 40.336253,  Lng: -76.681689),  Route carried "on" structure: City street ,  Year Built: 2011,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 200 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 280 (year 2039),  Design Load: HL 93,  Features Intersected: MANADA CREEK,  Facility Carried by Structure: T-469 CROOKED HILL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Toll: Toll bridge,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Good,  Operating Rating: 52.8 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 48088,  Location: HERSHEY (Lat: 40.286400,  Lng: -76.651397),  Route carried "on" structure: State highway 743,  Year Built: 2013,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 9,868 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 15,014 (year 2032),  Design Load: HL 93,  Features Intersected: Norfolk Southern RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.012,  Lanes on structure: 2,  Owner: State Highway Agency,  Maintenance Responsibility: Railroad,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 48576,  Location: 1 MI. S.E. HERSHEY (Lat: 40.275092,  Lng: -76.621856),  Route carried "on" structure: US 322,  Year Built: 2014,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 14,200 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 20,758 (year 2032),  Design Load: HL 93,  Features Intersected: SPRING CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.157,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 52641,  Location: Hershey park Access (Lat: 40.289175,  Lng: -76.668647),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 9,351 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 10,645 (year 2041),  Design Load: HL 93,  Features Intersected: Hershey Park Access Road,  Facility Carried by Structure: Park Blvd T-588
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Lanes under structure: 3,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 31.1m (102.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 31.1m (102.0ft),  Out-to-Out Width: 32.1m (105.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 53663,  Location: SW Side Hershey Park (Lat: 40.284206,  Lng: -76.663228),  Route carried "on" structure: City street ,  Year Built: 2016,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 6,485 (year 2017),  Truck Traffic: 9%,  Average Future Daily Traffic: 7,477 (year 2037),  Design Load: HL 93,  Features Intersected: Spring Creek,  Facility Carried by Structure: Park Blvd. T-591
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Toll: Toll bridge,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.9m (121.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 5.1m (16.7ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 76.5 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 49.2 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 54335,  Location: HERSHEY (Lat: 40.288389,  Lng: -76.652725),  Route carried "on" structure: State highway 743,  Year Built: 2017,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 9,868 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 15,014 (year 2032),  Design Load: HL 93,  Features Intersected: SPRING CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.012,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 57542,  Location: 500 FT WEST OF HARTLEY RD (Lat: 40.265606,  Lng: -76.647144),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 200 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 220 (year 2030),  Features Intersected: TRIBUTARY TO SPRING CREE,  Facility Carried by Structure: CAMBRIDGE DRIVE
Minimum Vertical Clearance: 30.18m (99.02ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 14384,  Location: 1 MI. E. HUMMELSTOWN (Lat: 40.266033,  Lng: -76.686972),  Route carried "under" structure: State highway 39,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 11,615 (year 2022),  Truck Traffic: 3%,  Features Intersected: US 322; SR 0322,  Facility Carried by Structure: US 422; SR 0422
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 28.030,  Lanes on structure: 5,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.4m (57.1ft)

Find on map >>   Show street view

Structure Number: 14384,  Location: 1 MI. E. HUMMELSTOWN (Lat: 40.266033,  Lng: -76.686972),  Route carried "under" structure: State highway 39,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 12,180 (year 2022),  Truck Traffic: 3%,  Features Intersected: US 322; SR 0322,  Facility Carried by Structure: US 422; SR 0422
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 28.061,  Lanes on structure: 5,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.4m (57.1ft)

Find on map >>   Show street view

Structure Number: 14384,  Location: 1 MI. E. HUMMELSTOWN (Lat: 40.266033,  Lng: -76.686972),  Route carried "under" structure: US 322,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 11,458 (year 2020),  Truck Traffic: 3%,  Features Intersected: US 322; SR 0322,  Facility Carried by Structure: US 422; SR 0422
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 11.587,  Lanes on structure: 5,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.4m (57.1ft)

Find on map >>   Show street view

Structure Number: 14621,  Location: LONDONDERRY TOWNSHIP (Lat: 40.208917,  Lng: -76.658083),  Route carried "under" structure: Interstate 76,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 24,423 (year 2001),  Truck Traffic: 24%,  Features Intersected: PA TPK (I-76),  Facility Carried by Structure: SR 0341, LR 624
Minimum Vertical Clearance: 4.49m (14.73ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 42.4m (139.1ft)

Discuss Hershey, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.