Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Hill City, South Dakota (SD)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 27Number of bridges
  • 105ft / 32.3mTotal length
  • $476,000Total costs
  • 103,665Total average daily traffic
  • 8,898Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Hill City
  • No street view available for this location

New bridges in Hill City, SD - historical statistics
  • New bridges - historical statistics
  • 21930-1939
  • 21960-1969
  • 91980-1989
  • 101990-1999
  • 22000-2009
  • 12010-2019
  • 12020-2022
Average Bridge Daily Traffic in Hill City, SD
Average Bridge Truck Traffic in Hill City, SD
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.7%Very good
  • 30.8%Good
  • 38.5%Satisfactory
  • 15.4%Fair
  • 7.7%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 7.7%Very good
  • 23.1%Good
  • 46.2%Satisfactory
  • 15.4%Fair
  • 7.7%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 53.8%Good
  • 23.1%Satisfactory
  • 15.4%Fair
  • 7.7%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 34.8%Excellent
  • 39.1%Very good
  • 13.0%Good
  • 13.0%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 16.7%Very good
  • 16.7%Good
  • 66.7%Satisfactory
Find on map >>   Show street view

Structure Number: 52221445,  Location: 1.6 N OF CUSTER CO LINE (Lat: 43.875197,  Lng: -103.614794),  Route carried "on" structure: US 16,  Year Built: 1998,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 6,855 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 10,810 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.454,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Excellent,  Culverts: Satisfactory,  Inventory Rating: 91.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 52224439,  Location: 2.4 N OF CUSTER CO LINE (Lat: 43.884239,  Lng: -103.605464),  Route carried "on" structure: US 16,  Year Built: 1996,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 6,855 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 10,810 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.725,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Excellent,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 70.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 52226438,  Location: 2.5 N OF CUSTER CO LINE (Lat: 43.885408,  Lng: -103.601406),  Route carried "on" structure: US 16,  Year Built: 1998,  Status: Open,  Structure Length: 0.75m (2.46ft),  Average Daily Traffic: 6,855 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 10,810 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 59.079,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Excellent,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 83.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 52231439,  Location: 3.0 N OF CUSTER CO LINE (Lat: 43.884128,  Lng: -103.595664),  Route carried "on" structure: US 16,  Year Built: 1998,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 6,855 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 10,810 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 59.578,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Excellent,  Culverts: Satisfactory,  Inventory Rating: 91.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 52232439,  Location: 3.1 N CUSTER CO LINE (Lat: 43.885050,  Lng: -103.593389),  Route carried "on" structure: US 16,  Year Built: 1998,  Status: Open,  Structure Length: 0.75m (2.46ft),  Average Daily Traffic: 6,855 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 10,810 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 59.803,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Excellent,  Culverts: Satisfactory,  Inventory Rating: 91.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 52236392,  Location: .3W & .9N HILL CITY (Lat: 43.952175,  Lng: -103.585936),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 537 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 537 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: NEWTON FORK CK,  Facility Carried by Structure: DEERFIELD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 65.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 52239394,  Location: .3W & .8N HILL CITY (Lat: 43.948092,  Lng: -103.581631),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 537 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 537 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: NEWTON FORK CK,  Facility Carried by Structure: DEERFIELD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 65.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 52239411,  Location: 0.5M S & 0.5M W HILL CITY (Lat: 43.920333,  Lng: -103.584058),  Route carried "on" structure: ServiceUS 16,  Year Built: 1980,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 10 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 15 (year 2040),  Design Load: HS 20,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 64.261,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.1m (23.3ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 4.3m (14.1ft),  Out-to-Out Width: 4.7m (15.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 80.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 52242403,  Location: OLD HWY16-N EDGE TOWN- HC (Lat: 43.936053,  Lng: -103.571750),  Route carried "on" structure: City street ,  Year Built: 1930,  Status: Posted for load,  Structure Length: 3.08m (10.10ft),  Average Daily Traffic: 1,000 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 1,368 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: ABANDON LINE RR,  Facility Carried by Structure: TOWN STREET (US16)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Operating Rating: 24.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Length Of Structure Improvement: 3.66m (12.01ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: August 2020,  Bridge Improvement Cost: $338,000,  Roadway Improvement Cost: $34,000,  Total Project Cost: $476,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 52243404,  Location: 200' EAST NEWTON ST (Lat: 43.934528,  Lng: -103.572000),  Route carried "on" structure: US 16,  Year Built: 1995,  Status: Open,  Structure Length: 1.17m (3.84ft),  Average Daily Traffic: 7,418 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 11,698 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 66.225,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 49.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52244404,  Location: 0.3E & 0.3N HILL CITY (Lat: 43.934908,  Lng: -103.568683),  Route carried "on" structure: US 16,  Year Built: 1995,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 7,418 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 11,698 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 66.498,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 22.6m (74.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 50.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52245404,  Location: MAJOR LK RD - HILL CITY (Lat: 43.935694,  Lng: -103.567883),  Route carried "on" structure: County highway ,  Year Built: 2021,  Status: Open,  Structure Length: 0.96m (3.15ft),  Average Daily Traffic: 917 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 917 (year 2032),  Design Load: HL 93,  Features Intersected: MAJOR LAKE SPILLWAY,  Facility Carried by Structure: MAJOR LAKE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.7m (15.4ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Excellent,  Culverts: Very good,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 52245405,  Location: 0.3N & 0.4E HILL CITY (Lat: 43.935031,  Lng: -103.567881),  Route carried "on" structure: US 16,  Year Built: 1995,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 7,418 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 11,698 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: NEWTON FORK CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 66.562,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 51.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 52256401,  Location: 1.2 E OF HILL CITY (Lat: 43.940258,  Lng: -103.546197),  Route carried "on" structure: US 16,  Year Built: 1986,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 6,892 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,869 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.622,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.0m (105.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 60.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52256434,  Location: 1.4E 2.7S HILL CITY (Lat: 43.891292,  Lng: -103.549222),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 1.29m (4.23ft),  Average Daily Traffic: 106 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 106 (year 2032),  Features Intersected: PALMER CK RD,  Facility Carried by Structure: PALMER GULCH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.1m (13.5ft),  Skew: 3 degrees,  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 4.1m (13.5ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 52257401,  Location: 1.8 W JCT US 385 (Lat: 43.940419,  Lng: -103.544419),  Route carried "on" structure: US 16,  Year Built: 1986,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 6,892 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,869 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.767,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.2m (17.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 90.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 52261397,  Location: 1.2 W JCT US 385 (Lat: 43.945158,  Lng: -103.535892),  Route carried "on" structure: US 16,  Year Built: 1986,  Status: Open,  Structure Length: 0.89m (2.92ft),  Average Daily Traffic: 6,892 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,869 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 69.910,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 79.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 52261398,  Location: 1.3 W JCT US 385 (Lat: 43.942886,  Lng: -103.537164),  Route carried "on" structure: US 16,  Year Built: 1986,  Status: Open,  Structure Length: 0.89m (2.92ft),  Average Daily Traffic: 6,892 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,869 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 69.636,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 71.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 52261399,  Location: 2E & 0.8N HILL CITY (Lat: 43.942478,  Lng: -103.536114),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Posted for load,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 106 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 106 (year 2032),  Features Intersected: SPRING CK,  Facility Carried by Structure: SPRING CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 6.8m (22.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 24.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 18.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 52261428,  Location: 3.2 E JCT US 385 & 16 (Lat: 43.900472,  Lng: -103.535806),  Route carried "on" structure: State highway 244,  Year Built: 1966,  Status: Open,  Structure Length: 2.12m (6.96ft),  Average Daily Traffic: 4,714 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 7,434 (year 2041),  Design Load: HS 20,  Features Intersected: PALMER GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 43.597,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Very good,  Operating Rating: 44.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 31.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 52266397,  Location: 2.6E & 0.8N Hill City (Lat: 43.944869,  Lng: -103.525469),  Route carried "on" structure: County highway ,  Year Built: 2016,  Status: Open,  Structure Length: 0.87m (2.85ft),  Average Daily Traffic: 106 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 106 (year 2034),  Features Intersected: SPRING CREEK,  Facility Carried by Structure: PALMER GULCH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 52273394,  Location: 0.2 E JCT US 385 (Lat: 43.947894,  Lng: -103.513586),  Route carried "on" structure: US 16,  Year Built: 1985,  Status: Open,  Structure Length: 1.20m (3.94ft),  Average Daily Traffic: 6,155 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 9,706 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 72.678,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.5m (34.4ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 63.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52273397,  Location: 0.5 E JCT US 385 (Lat: 43.944803,  Lng: -103.513736),  Route carried "on" structure: ServiceUS 16,  Year Built: 1985,  Status: Open,  Structure Length: 0.96m (3.15ft),  Average Daily Traffic: 60 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 60 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 73.016,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.5m (31.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 5227939,  Location: 0.8 NE JCT US 16 E (Lat: 43.954922,  Lng: -103.500639),  Route carried "on" structure: ServiceUS 385,  Year Built: 1996,  Status: Open,  Structure Length: 3.02m (9.91ft),  Average Daily Traffic: 5 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 6 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 138.806,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.9m (35.8ft),  Curb-To-Curb Width: 4.3m (14.1ft),  Out-to-Out Width: 4.5m (14.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 73.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 52283387,  Location: 1.3 NE JCT US 16 E (Lat: 43.959494,  Lng: -103.493381),  Route carried "on" structure: ServiceUS 385,  Year Built: 1996,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 5 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 6 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SPRING CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 139.611,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Frame,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Excellent,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 52234432,  Location: 0.1N OF JCT SD87 (Lat: 43.894589,  Lng: -103.590692),  Route carried "under" structure: US 16,  Year Built: 1937,  Structure Length: 0. m,  Average Daily Traffic: 5,204 (year 2018),  Truck Traffic: 6%,  Features Intersected: US16 & US385,  Facility Carried by Structure: MICKELSON TRAIL
Minimum Vertical Clearance: 4.83m (15.85ft),  Kilometerpoint: 61.026,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 52256434,  Location: 1.4E 2.7S HILL CITY (Lat: 43.891292,  Lng: -103.549222),  Route carried "under" structure: County highway ,  Year Built: 2009,  Structure Length: 0. m,  Average Daily Traffic: 106 (year 2019),  Truck Traffic: 1%,  Features Intersected: PALMER CK RD,  Facility Carried by Structure: PALMER GULCH RD
Minimum Vertical Clearance: 4.11m (13.48ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Wood or Timber,  Design/Construction: Slab,  Length of Maximum Span: 12.2m (40.0ft)