Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Holladay, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 20Number of bridges
  • 157ft / 47.8mTotal length
  • 438,709Total average daily traffic
  • 50,368Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Holladay
  • No street view available for this location

New bridges in Holladay, UT - historical statistics
  • New bridges - historical statistics
  • 31930-1939
  • 31940-1949
  • 11960-1969
  • 91980-1989
  • 22000-2009
  • 22020-2022
Reconstructed bridges in Holladay, UT - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 11960-1969
Average Bridge Daily Traffic in Holladay, UT
Average Bridge Truck Traffic in Holladay, UT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 6.7%Very good
  • 26.7%Good
  • 53.3%Satisfactory
  • 6.7%Fair
  • 6.7%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 6.7%Very good
  • 40.0%Good
  • 33.3%Satisfactory
  • 6.7%Fair
  • 13.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 33.3%Good
  • 40.0%Satisfactory
  • 26.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 10.0%Very good
  • 50.0%Good
  • 40.0%Satisfactory
Find on map >>   Show street view

Structure Number: 35062C,  Location: 4750 SO.1750 E., SL.CO. (Lat: 40.665000,  Lng: -111.840075),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 1.44m (4.72ft),  Average Daily Traffic: 1,021 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,240 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BIG COTTONWOOD CREEK,  Facility Carried by Structure: HIGHLAND CIRCLE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.039,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 15 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.3m (43.6ft),  Curb-To-Curb Width: 4.1m (13.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 35064D,  Location: 5250 SO.2350 E.,HOLLADAY (Lat: 40.656167,  Lng: -111.824019),  Route carried "on" structure: City street 2184,  Year Built: 1940,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 500 (year 2020),  Average Future Daily Traffic: 625 (year 2040),  Design Load: HL 93,  Features Intersected: BIG COTTONWOOD CREEK,  Facility Carried by Structure: COTTONWOOD LANE
Minimum Vertical Clearance: 30.18m (99.02ft),  Kilometerpoint: 1.242,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.8m (25.6ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 35065D,  Location: 2025 E.5450 SO.,HOLLADAY (Lat: 40.652053,  Lng: -111.834339),  Route carried "on" structure: City street 2184,  Year Built: 1938,  Status: Posted for load,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 500 (year 2020),  Average Future Daily Traffic: 625 (year 2040),  Design Load: HL 93,  Features Intersected: JORDAN SALT LAKE CANAL,  Facility Carried by Structure: WALKER LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.052,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 35066D,  Location: 4850 SO.1850 E.,HOLLADAY (Lat: 40.663711,  Lng: -111.838750),  Route carried "on" structure: City street 2266,  Year Built: 1936,  Year Reconstructed: 1964,  Status: Posted for load,  Structure Length: 1.14m (3.74ft),  Average Daily Traffic: 18,276 (year 2020),  Average Future Daily Traffic: 22,845 (year 2040),  Design Load: HS 20,  Features Intersected: BIG COTTONWOOD CREEK,  Facility Carried by Structure: HIGHLAND DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.715,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 23.3m (76.4ft),  Skew: 24 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 23.3m (76.4ft),  Out-to-Out Width: 26.8m (87.9ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Fair,  Channel: Good,  Operating Rating: 31.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 35067C,  Location: 6400 SO. HOLLADAY BLVD. (Lat: 40.635444,  Lng: -111.811472),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 1.80m (5.91ft),  Average Daily Traffic: 252 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 306 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BIG COTTONWOOD CREEK,  Facility Carried by Structure: HOLLADAY BOULEVARD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 35068D,  Location: 2050 E.5000 SO.,HOLLADAY (Lat: 40.660308,  Lng: -111.833008),  Route carried "on" structure: City street ,  Year Built: 1945,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 1,021 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,240 (year 2040),  Design Load: HL 93,  Features Intersected: BIG COTTONWOOD CREEK,  Facility Carried by Structure: ARBOR LN.(5000 SO)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.185,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.6m (21.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 35069D,  Location: 2800 E. 6200 SO.,HOLLADAY (Lat: 40.637806,  Lng: -111.812989),  Route carried "on" structure: City street 2158,  Year Built: 1935,  Status: Posted for load,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 8,589 (year 2020),  Average Future Daily Traffic: 10,736 (year 2040),  Design Load: HL 93,  Features Intersected: BIG COTTONWOOD CREEK,  Facility Carried by Structure: 6200 SOUTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.852,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 35110D,  Location: 4820 S.1665 E., HOLLADAY (Lat: 40.664778,  Lng: -111.844614),  Route carried "on" structure: City street ,  Year Built: 1965,  Status: Open,  Structure Length: 0.80m (2.62ft),  Average Daily Traffic: 1,890 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,296 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BIG COTTONWOOD CREEK,  Facility Carried by Structure: KINGS ROW DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.036,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.1m (23.3ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 11.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 35131D,  Location: 1900 E. 5600 SO., SL.CO. (Lat: 40.649392,  Lng: -111.837333),  Route carried "on" structure: County highway 2122,  Year Built: 1940,  Year Reconstructed: 1960,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 6,523 (year 2020),  Average Future Daily Traffic: 8,154 (year 2040),  Design Load: HL 93,  Features Intersected: JORDAN SALT LAKE CANAL,  Facility Carried by Structure: 5600 SOUTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.342,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Other Special Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: C 757,  Location: KNUDSON'S CORNER (Lat: 40.638206,  Lng: -111.808511),  Route carried "on" structure: Interstate 215,  Year Built: 1989,  Status: Open,  Structure Length: 14.17m (46.49ft),  Average Daily Traffic: 60,831 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 76,039 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-190
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.014,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 34.1m (111.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 64.6m (211.9ft),  Curb-To-Curb Width: 35.9m (117.8ft),  Out-to-Out Width: 37.9m (124.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C 953,  Location: 4430 South Wasatch Blv. (Lat: 40.674603,  Lng: -111.802986),  Route carried "on" structure: State highway 266,  Year Built: 2007,  Status: Open,  Structure Length: 5.34m (17.52ft),  Average Daily Traffic: 14,915 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 18,644 (year 2040),  Design Load: HL 93,  Features Intersected: I-215, (SR-215)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.961,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.8m (65.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 52.5m (172.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.6m (67.6ft),  Out-to-Out Width: 25.1m (82.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 56.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F 458,  Location: 5800 SOUTH and I-215 (Lat: 40.646139,  Lng: -111.808517),  Route carried "on" structure: Interstate 215,  Year Built: 1989,  Status: Open,  Structure Length: 4.34m (14.24ft),  Average Daily Traffic: 60,831 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 76,039 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: 5800 SOUTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.131,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 34.1m (111.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.7m (140.1ft),  Curb-To-Curb Width: 36.0m (118.1ft),  Out-to-Out Width: 38.0m (124.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 74.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F 505,  Location: 6400 SO. 2300 EAST (Lat: 40.634042,  Lng: -111.824717),  Route carried "on" structure: County highway 2226,  Year Built: 1988,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 12,081 (year 2020),  Average Future Daily Traffic: 15,101 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-215 (SR-215) EBL &,  Facility Carried by Structure: 2300 EAST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.328,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.3m (128.9ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 17.6m (57.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4C 76,  Location: .2 MI.SW.KNUDSON CNR.INT (Lat: 40.635592,  Lng: -111.811050),  Route carried "on" structure: Ramp Interstate 215,  Year Built: 1989,  Status: Open,  Structure Length: 5.20m (17.06ft),  Average Daily Traffic: 25,500 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 31,875 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HLDY.BLVD.& BIG CTWD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.324,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 48.8m (160.1ft),  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 79.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C1092,  Location: I-80 Temp over 2300 (Lat: 40.713047,  Lng: -111.822433),  Route carried "on" structure: Interstate 80,  Year Built: 2021,  Status: Temporarily open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 90,775 (year 2020),  Truck Traffic: 18%,  Average Future Daily Traffic: 113,469 (year 2040),  Design Load: HL 93,  Features Intersected: 2300 East Temp
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 204.031,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.5m (67.3ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C 757,  Location: KNUDSON'S CORNER (Lat: 40.638206,  Lng: -111.808511),  Route carried "under" structure: State highway 190,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 12,311 (year 2020),  Truck Traffic: 13%,  Features Intersected: SR-190,  Facility Carried by Structure: I-215 (SR-215)
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 0.129,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 64.6m (211.9ft)

Find on map >>   Show street view

Structure Number: C 953,  Location: 4430 South Wasatch Blv. (Lat: 40.674603,  Lng: -111.802986),  Route carried "under" structure: Interstate 215,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 60,831 (year 2020),  Truck Traffic: 11%,  Features Intersected: I-215, (SR-215),  Facility Carried by Structure: SR-266,4300 SO.ST.
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 5.921,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.5m (172.2ft)

Find on map >>   Show street view

Structure Number: F 505,  Location: 6400 SO. 2300 EAST (Lat: 40.634042,  Lng: -111.824717),  Route carried "under" structure: Interstate 215,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 62,062 (year 2020),  Truck Traffic: 12%,  Features Intersected: I-215 (SR-215) EBL &,  Facility Carried by Structure: 2300 EAST STREET
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 11.632,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.3m (128.9ft)

Find on map >>   Show street view

Structure Number: 4C 76,  Location: .2 MI.SW.KNUDSON CNR.INT (Lat: 40.635592,  Lng: -111.811050),  Route carried "under" structure: County highway ,  Year Built: 1989,  Structure Length: 0. m,  Features Intersected: HLDY.BLVD.& BIG CTWD,  Facility Carried by Structure: I-215 WB.ON-RAMP
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 48.8m (160.1ft)

Find on map >>   Show street view

Structure Number: C1092,  Location: I-80 Temp over 2300 (Lat: 40.713047,  Lng: -111.822433),  Route carried "under" structure: Ramp City street 195,  Year Built: 2021,  Structure Length: 0. m,  Features Intersected: 2300 East Temp,  Facility Carried by Structure: I-80
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.5m (67.3ft)

Discuss Holladay, Utah (UT) on our hugely popular Utah forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.