Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Keystone, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 112ft / 33.6mTotal length
  • 312,399Total average daily traffic
  • 29,435Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Keystone
  • No street view available for this location

New bridges in Keystone, FL - historical statistics
  • New bridges - historical statistics
  • 11960-1969
  • 11980-1989
  • 11990-1999
  • 152000-2009
Average Bridge Daily Traffic in Keystone, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 37.5%Very good
  • 62.5%Good
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 12.5%Very good
  • 62.5%Good
  • 25.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 87.5%Good
  • 12.5%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 83.3%Good
  • 16.7%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 75.0%Good
  • 25.0%Satisfactory
Find on map >>   Show street view

Structure Number: 100625,  Location: 0.3MI N OF VETERANS EXPWY (Lat: 28.125853,  Lng: -82.547475),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 44,900 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 77,902 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: ROCKY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.307,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.7m (120.4ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Fair,  Culverts: Good,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 100626,  Location: 0.7MI N OF VET EXPRESSWAY (Lat: 28.128547,  Lng: -82.548139),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 38,430 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: VAN DYKE RD. CR 685A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.641,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.2m (154.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 60.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 100627,  Location: 0.7MI N OF VET EXPRESSWAY (Lat: 28.128558,  Lng: -82.548386),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 38,430 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: VAN DYKE RD. CR 685A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.648,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.2m (154.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 60.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 100628,  Location: 1.0 MI N OF VAN DYKE RD (Lat: 28.143094,  Lng: -82.545842),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 2.21m (7.25ft),  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 38,430 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: RAMBLEWOOD BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.297,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 13.3m (43.6ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.1m (72.5ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 100629,  Location: 1.0 MI N OF VAN DYKE RD (Lat: 28.143114,  Lng: -82.546058),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 2.21m (7.25ft),  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 38,430 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: RAMBLEWOOD BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.291,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 13.3m (43.6ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.1m (72.5ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 100632,  Location: 2.0 MI N OF VAN DYKE (Lat: 28.156061,  Lng: -82.537631),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 4.97m (16.31ft),  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 38,430 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LUTZ LAKE FERN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.944,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 17.4m (57.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 17.4m (57.1ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 39.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 100633,  Location: 2.0 MI N OF VAN DYKE (Lat: 28.156044,  Lng: -82.537900),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 5.01m (16.44ft),  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 38,430 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LUTZ LAKE FERN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.944,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 13.6m (44.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 17.4m (57.1ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 39.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 104204,  Location: 0.2MI W OF PATTERSON ROAD (Lat: 28.140806,  Lng: -82.639444),  Route carried "on" structure: County highway 582,  Year Built: 1984,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 6,649 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 8,311 (year 2041),  Design Load: HS 20,  Features Intersected: BROOKER CREEK,  Facility Carried by Structure: TARPON SPRINGS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.152,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.7m (25.3ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 45.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 104247,  Location: 0.9 MI W OF CR-587 (Lat: 28.147372,  Lng: -82.593750),  Route carried "on" structure: County highway 582,  Year Built: 1960,  Status: Open,  Structure Length: 0.74m (2.43ft),  Average Daily Traffic: 8,550 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,687 (year 2041),  Features Intersected: KEYSTONE WATER PASSAGE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.789,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.4m (24.3ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Underwater Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 104273,  Location: 0.5 MI S OF VAN DYKE ROAD (Lat: 28.123417,  Lng: -82.577264),  Route carried "on" structure: County highway 587,  Year Built: 1990,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 12,900 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 16,125 (year 2041),  Design Load: HS 20,  Features Intersected: BROOKER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.6m (11.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 87.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Underwater Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 104299,  Location: 0.2MI S OF VAN DYKE RD (Lat: 28.125333,  Lng: -82.550350),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 5,000 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 8,675 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: ROCKY CREEK,  Facility Carried by Structure: TOBACCO ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.420,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.2m (43.3ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 72.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 104604,  Location: 1MI S OF S MOBLEY (Lat: 28.074406,  Lng: -82.625961),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 14,600 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 34,500 (year 2041),  Design Load: HS 20,  Features Intersected: DOUBLE BRANCH CREEK,  Facility Carried by Structure: RACE TRACK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 21 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 28.8m (94.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 79.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 100626,  Location: 0.7MI N OF VET EXPRESSWAY (Lat: 28.128547,  Lng: -82.548139),  Route carried "under" structure: County highway 685A,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 14,900 (year 2020),  Truck Traffic: 13%,  Features Intersected: VAN DYKE RD. CR 685A,  Facility Carried by Structure: SR 589 NB SCP 14.2
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 2.636,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 47.2m (154.9ft)

Find on map >>   Show street view

Structure Number: 100627,  Location: 0.7MI N OF VET EXPRESSWAY (Lat: 28.128558,  Lng: -82.548386),  Route carried "under" structure: County highway 685A,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 14,900 (year 2020),  Truck Traffic: 13%,  Features Intersected: VAN DYKE RD. CR 685A,  Facility Carried by Structure: SR 589 SB SCP 14.2
Minimum Vertical Clearance: 5.73m (18.80ft),  Kilometerpoint: 2.610,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 47.2m (154.9ft)

Find on map >>   Show street view

Structure Number: 100628,  Location: 1.0 MI N OF VAN DYKE RD (Lat: 28.143094,  Lng: -82.545842),  Route carried "under" structure: City street ,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Features Intersected: RAMBLEWOOD BLVD,  Facility Carried by Structure: SR 589 NB SCP 15.2
Minimum Vertical Clearance: 5.07m (16.63ft),  Kilometerpoint: 22.301,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.1m (72.5ft)

Find on map >>   Show street view

Structure Number: 100629,  Location: 1.0 MI N OF VAN DYKE RD (Lat: 28.143114,  Lng: -82.546058),  Route carried "under" structure: City street ,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 22,150 (year 2020),  Truck Traffic: 10%,  Features Intersected: RAMBLEWOOD BLVD,  Facility Carried by Structure: SR 589 SB SCP 15.2
Minimum Vertical Clearance: 6.35m (20.83ft),  Kilometerpoint: 22.294,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.1m (72.5ft)

Find on map >>   Show street view

Structure Number: 100632,  Location: 2.0 MI N OF VAN DYKE (Lat: 28.156061,  Lng: -82.537631),  Route carried "under" structure: County highway ,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 6,400 (year 2020),  Truck Traffic: 9%,  Features Intersected: LUTZ LAKE FERN ROAD,  Facility Carried by Structure: SR 589 NB SCP 16.3
Minimum Vertical Clearance: 6.62m (21.72ft),  Kilometerpoint: 12.606,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 100633,  Location: 2.0 MI N OF VAN DYKE (Lat: 28.156044,  Lng: -82.537900),  Route carried "under" structure: County highway ,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 6,400 (year 2020),  Truck Traffic: 9%,  Features Intersected: LUTZ LAKE FERN ROAD,  Facility Carried by Structure: SR 589 SB SCP 16.3
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 12.579,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Discuss Keystone, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.