Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Lafayette, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 23Number of bridges
  • 299ft / 90.6mTotal length
  • $380,000Total costs
  • 396,322Total average daily traffic
  • 23,322Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Lafayette
  • No street view available for this location

New bridges in Lafayette, CO - historical statistics
  • New bridges - historical statistics
  • 21920-1929
  • 11970-1979
  • 11980-1989
  • 81990-1999
  • 112000-2009
Average Bridge Daily Traffic in Lafayette, CO
Average Bridge Truck Traffic in Lafayette, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 76.9%Good
  • 15.4%Satisfactory
  • 7.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 7.7%Very good
  • 30.8%Good
  • 53.8%Satisfactory
  • 7.7%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 30.8%Good
  • 69.2%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 41.7%Good
  • 16.7%Satisfactory
  • 8.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 14.3%Good
  • 57.1%Satisfactory
  • 28.6%Fair
Find on map >>   Show street view

Structure Number: D-16-BW,  Location: 0.35 MI E OF 75th ST (Lat: 40.014681,  Lng: -105.171467),  Route carried "on" structure: State highway 7C,  Year Built: 1928,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 19,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 24,130 (year 2040),  Design Load: H 15,  Features Intersected: DRAW,  Facility Carried by Structure: SH 7 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.443,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.06m (3.48ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $166,000,  Roadway Improvement Cost: $17,000,  Total Project Cost: $183,000 ( Estimate for 2019)
Find on map >>   Show street view

Structure Number: D-16-DM,  Location: 2.3 MI E OF JCT US 287 (Lat: 40.000314,  Lng: -105.058450),  Route carried "on" structure: State highway 7D,  Year Built: 1990,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 17,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 22,440 (year 2040),  Design Load: HS 20,  Features Intersected: COAL CREEK,  Facility Carried by Structure: SH 7 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.792,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 30.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-16-MT,  Location: 0.4 MI S of NW PKWY (Lat: 39.952000,  Lng: -105.090100),  Route carried "on" structure: US 287C,  Year Built: 1993,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 16,500 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 19,470 (year 2040),  Design Load: HS 20,  Features Intersected: ROCK CREEK,  Facility Carried by Structure: US 287 NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.691,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.0m (108.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-16-NG,  Location: JUST N OF NW PKWY (Lat: 39.961317,  Lng: -105.090006),  Route carried "on" structure: US 287C,  Year Built: 1993,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 39,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 48,750 (year 2040),  Design Load: HS 20,  Features Intersected: DRAW,  Facility Carried by Structure: US 287
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.728,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.8m (87.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft),  Out-to-Out Width: 44.5m (146.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.76m (2.49ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $131,000,  Roadway Improvement Cost: $13,000,  Total Project Cost: $197,000
Find on map >>   Show street view

Structure Number: E-16-NH,  Location: IN BOULDER COUNTY (Lat: 39.965319,  Lng: -105.090061),  Route carried "on" structure: US 287C,  Year Built: 1994,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 39,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 48,750 (year 2040),  Design Load: HS 20,  Features Intersected: DRAW,  Facility Carried by Structure: US 287 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.172,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 28.7m (94.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.9m (9.5ft),  Out-to-Out Width: 45.1m (148.0ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: E-16-PN,  Location: IN BOULDER COUNTY (Lat: 39.979722,  Lng: -105.097528),  Route carried "on" structure: US 287C,  Year Built: 1996,  Status: Open,  Structure Length: 4.30m (14.11ft),  Average Daily Traffic: 32,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 42,880 (year 2040),  Features Intersected: COAL CREEK,  Facility Carried by Structure: US 287 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.113,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.1m (69.2ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 0.0m,  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 31.7m (104.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 60.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-16-PO,  Location: IN LAFAYETTE (Lat: 39.986814,  Lng: -105.098847),  Route carried "on" structure: ServiceUS 287C,  Year Built: 1996,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 34,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 44,880 (year 2040),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH AR,  Facility Carried by Structure: SOUTH BOULDER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.518,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 29.3m (96.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Out-to-Out Width: 28.0m (91.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: E-16-PQ,  Location: IN LAFAYETTE (Lat: 39.994100,  Lng: -105.102836),  Route carried "on" structure: City street ,  Year Built: 1994,  Status: Open,  Structure Length: 6.19m (20.31ft),  Average Daily Traffic: 3,129 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 4,000 (year 2028),  Design Load: HS 20,  Features Intersected: US 287 ML,  Facility Carried by Structure: EMMA ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.423,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.9m (98.1ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: LAF-120TH-001B,  Location: 0.5 Mi S of S. Boulder Rd (Lat: 39.977111,  Lng: -105.072000),  Route carried "on" structure: City street ,  Year Built: 1986,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 1.26m (4.13ft),  Average Daily Traffic: 4,287 (year 2020),  Truck Traffic: 30%,  Average Future Daily Traffic: 5,144 (year 2040),  Design Load: HS 20,  Features Intersected: Rock Creek,  Facility Carried by Structure: 120TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.536,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 21.4m (70.2ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 30.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: LAF-120TH-002,  Location: 0.25 M S of S. Boulder Rd (Lat: 39.982333,  Lng: -105.071889),  Route carried "on" structure: City street ,  Year Built: 1977,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 8,495 (year 2020),  Truck Traffic: 24%,  Average Future Daily Traffic: 10,194 (year 2040),  Design Load: HS 20,  Features Intersected: Coal Creek,  Facility Carried by Structure: 120TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.066,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.0m (16.4ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: LAF-HORIZ-004,  Location: .1 MI East 120th (Lat: 39.980222,  Lng: -105.070278),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 2,284 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 2,741 (year 2040),  Design Load: HS 20,  Features Intersected: Rock Creek,  Facility Carried by Structure: Horizon Avenue
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.135,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Inventory Rating: 64.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: LAF-PUBRD-003,  Location: .25 M N of Jct US Hwy 287 (Lat: 39.979639,  Lng: -105.090556),  Route carried "on" structure: City street ,  Year Built: 1927,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 17,986 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 21,583 (year 2040),  Design Load: H 15,  Features Intersected: Coal Creek,  Facility Carried by Structure: Public Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.169,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: NWP-05.69,  Location: 5.69 MI FROM I-25 (Lat: 39.958525,  Lng: -105.095539),  Route carried "on" structure: Ramp Other road 470N,  Year Built: 2002,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 16,320 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: Rock Creek,  Facility Carried by Structure: NWP Ramp
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 10.029,  Lanes on structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 42.6m (139.8ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: NWP-05.81A,  Location: 5.81 MI FROM I-25 (Lat: 39.958611,  Lng: -105.088056),  Route carried "on" structure: Other road 470N,  Year Built: 2002,  Status: Open,  Structure Length: 6.84m (22.44ft),  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 16,320 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: BNSF,  Facility Carried by Structure: NWP EB
Minimum Vertical Clearance: 30.18m (99.02ft),  Kilometerpoint: 9.394,  Lanes on structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.2m (79.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 70.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: NWP-05.81B,  Location: 5.81 MI FROM I-25 (Lat: 39.958889,  Lng: -105.087778),  Route carried "on" structure: Other road 470N,  Year Built: 2002,  Status: Open,  Structure Length: 6.84m (22.44ft),  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 16,320 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: BNSF,  Facility Carried by Structure: NWP WB
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 9.366,  Lanes on structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.2m (79.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 70.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: NWP-05.95A,  Location: 5.95 FROM I-25 (Lat: 39.958333,  Lng: -105.090556),  Route carried "on" structure: Other road 470N,  Year Built: 2002,  Status: Open,  Structure Length: 7.51m (24.64ft),  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 16,320 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: US 287,  Facility Carried by Structure: NWP EB
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 9.606,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.1m (118.4ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 68.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: NWP-05.95B,  Location: 5.95 FROM I-25 (Lat: 39.958611,  Lng: -105.090556),  Route carried "on" structure: Other road 470N,  Year Built: 2002,  Status: Open,  Structure Length: 7.51m (24.64ft),  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 16,320 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: US 287,  Facility Carried by Structure: NWP WB
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 9.605,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.1m (118.4ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 68.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: NWP-06.25A,  Location: 6.25 MI FROM I-25 (Lat: 39.958317,  Lng: -105.095539),  Route carried "on" structure: Other road NWPKY,  Year Built: 2002,  Status: Open,  Structure Length: 9.60m (31.50ft),  Average Daily Traffic: 6,268 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 15,960 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: EB Dillon Road,  Facility Carried by Structure: NWP EB
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 10.031,  Lanes on structure: 2,  Lanes under structure: 1,  Base Highway Network: Yes,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 44.6m (146.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: NWP-06.25B,  Location: 6.25 MI FROM I-25 (Lat: 39.958478,  Lng: -105.095933),  Route carried "on" structure: Other road NWPKY,  Year Built: 2002,  Status: Open,  Structure Length: 9.60m (31.50ft),  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 16,320 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: EB Dillon Road,  Facility Carried by Structure: NWP WB
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 10.063,  Lanes on structure: 2,  Lanes under structure: 1,  Base Highway Network: Yes,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 44.6m (146.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: NWP-06.29,  Location: 6.29 MI FROM I-25 (Lat: 39.958772,  Lng: -105.096544),  Route carried "on" structure: Ramp Other road 470N,  Year Built: 2002,  Status: Open,  Structure Length: 8.90m (29.20ft),  Average Daily Traffic: 1,100 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,000 (year 2029),  Design Load: HS 25 or greater,  Features Intersected: EB Dillon Road,  Facility Carried by Structure: NWP Ramp
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 0.317,  Lanes on structure: 1,  Lanes under structure: 1,  Base Highway Network: Yes,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 40.4m (132.5ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-16-PQ,  Location: IN LAFAYETTE (Lat: 39.994100,  Lng: -105.102836),  Route carried "under" structure: US 287C,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 3,673 (year 2016),  Truck Traffic: 6%,  Features Intersected: US 287 ML,  Facility Carried by Structure: EMMA ST.
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.423,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 29.9m (98.1ft)

Find on map >>   Show street view

Structure Number: NWP-05.95A,  Location: 5.95 FROM I-25 (Lat: 39.958333,  Lng: -105.090556),  Route carried "under" structure: US 287C,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 40,300 (year 2007),  Truck Traffic: 5%,  Features Intersected: US 287,  Facility Carried by Structure: NWP EB
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 484.001,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.1m (118.4ft)

Find on map >>   Show street view

Structure Number: NWP-05.95B,  Location: 5.95 FROM I-25 (Lat: 39.958611,  Lng: -105.090556),  Route carried "under" structure: US 287C,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 40,300 (year 2007),  Truck Traffic: 5%,  Features Intersected: US 287,  Facility Carried by Structure: NWP WB
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 484.001,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.1m (118.4ft)

Discuss Lafayette, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.