Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Lakewood, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 246ft / 75.5mTotal length
  • 567,126Total average daily traffic
  • 28,872Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Lakewood
  • No street view available for this location

New bridges in Lakewood, OH - historical statistics
  • New bridges - historical statistics
  • 11950-1959
  • 101970-1979
Average Bridge Daily Traffic in Lakewood, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 14.3%Very good
  • 71.4%Good
  • 14.3%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 71.4%Good
  • 14.3%Satisfactory
  • 14.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Very good
  • 57.1%Good
  • 28.6%Satisfactory
Find on map >>   Show street view

Structure Number: 1808567,  Location: .07 MI W OF JCT SR237 (Lat: 41.471869,  Lng: -81.824650),  Route carried "on" structure: Interstate 90,  Year Built: 1971,  Status: Open,  Structure Length: 25.57m (83.89ft),  Average Daily Traffic: 106,617 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 147,984 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: ROCKY RIVER VALLEY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.199,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 59.4m (194.9ft),  Curb-To-Curb Width: 42.7m (140.1ft),  Out-to-Out Width: 43.9m (144.0ft)

Condition: Deck: Good,  Superstructure: Poor,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Critical Feature Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 1808575,  Location: SR237 AND IR90 JCT (Lat: 41.471800,  Lng: -81.822650),  Route carried "on" structure: State highway 237,  Year Built: 1971,  Status: Open,  Structure Length: 7.65m (25.10ft),  Average Daily Traffic: 6,563 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 9,109 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: I-90 (CUY-90-0775)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.891,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.5m (77.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1808591,  Location: .10 MI E OF JCT SR237 (Lat: 41.471461,  Lng: -81.821239),  Route carried "on" structure: County highway 69,  Year Built: 1971,  Status: Open,  Structure Length: 6.68m (21.92ft),  Average Daily Traffic: 10,217 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,181 (year 2035),  Design Load: H 20,  Features Intersected: IR-90 (HILLARD),  Facility Carried by Structure: HILLIARD ROAD CR-6
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.059,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.6m (107.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Cathodic Protection
Find on map >>   Show street view

Structure Number: 1808621,  Location: .35 MI E OF JCT SR237 (Lat: 41.470411,  Lng: -81.816261),  Route carried "on" structure: City street MCKIN,  Year Built: 1971,  Status: Open,  Structure Length: 7.96m (26.12ft),  Average Daily Traffic: 6,702 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,302 (year 2035),  Design Load: H 20,  Features Intersected: IR-90 (MCKINLEY)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.299,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 25.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Cathodic Protection
Find on map >>   Show street view

Structure Number: 1808656,  Location: .59 MI E OF JCT SR237 (Lat: 41.469469,  Lng: -81.811761),  Route carried "on" structure: City street WDWRD,  Year Built: 1971,  Status: Open,  Structure Length: 8.53m (27.99ft),  Average Daily Traffic: 4,664 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 130,583 (year 2035),  Design Load: H 20,  Features Intersected: I-90,  Facility Carried by Structure: WOODWARD AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.0m (95.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Cathodic Protection
Find on map >>   Show street view

Structure Number: 1890077,  Location: 1000 FT S of Rockliff Ln (Lat: 41.469200,  Lng: -81.832311),  Route carried "on" structure: Other road CMP,  Year Built: 1970,  Status: Open,  Structure Length: 10.42m (34.19ft),  Average Daily Traffic: 5,000 (year 1995),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,940 (year 2015),  Design Load: HS 20+Mod,  Features Intersected: Rocky River,  Facility Carried by Structure: Valley Parkway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Local Park, Forest, or Reservation Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 39.6m (129.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1891057,  Location: 100' S of Scenic Park Ent (Lat: 41.478331,  Lng: -81.828611),  Route carried "on" structure: Other road CMP,  Year Built: 1959,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 8.66m (28.41ft),  Average Daily Traffic: 5,000 (year 1995),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,940 (year 2015),  Features Intersected: Rocky River,  Facility Carried by Structure: Valley Parkway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: Local Park, Forest, or Reservation Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 1808575,  Location: SR237 AND IR90 JCT (Lat: 41.471800,  Lng: -81.822650),  Route carried "under" structure: Interstate 90,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 106,617 (year 2015),  Truck Traffic: 5%,  Features Intersected: RIVERSIDE DR, SR 237-123,  Facility Carried by Structure: RIVERSIDE DR-SR237
Minimum Vertical Clearance: 5.58m (18.31ft),  Kilometerpoint: 12.472,  Lanes on structure: 3,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 1808591,  Location: .10 MI E OF JCT SR237 (Lat: 41.471461,  Lng: -81.821239),  Route carried "under" structure: Interstate 90,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 110,833 (year 2016),  Truck Traffic: 5%,  Features Intersected: CR-69 (HILLIARD RD),  Facility Carried by Structure: HILLIARD ROAD CR-6
Minimum Vertical Clearance: 5.44m (17.85ft),  Kilometerpoint: 12.616,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 1808621,  Location: .35 MI E OF JCT SR237 (Lat: 41.470411,  Lng: -81.816261),  Route carried "under" structure: Interstate 90,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 110,833 (year 2016),  Truck Traffic: 5%,  Features Intersected: MCKINLEY AVE (CR-736),  Facility Carried by Structure: MCKINLEY AVENUE
Minimum Vertical Clearance: 4.53m (14.86ft),  Kilometerpoint: 13.028,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 1808656,  Location: .59 MI E OF JCT SR237 (Lat: 41.469469,  Lng: -81.811761),  Route carried "under" structure: Interstate 90,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 94,080 (year 2015),  Truck Traffic: 5%,  Features Intersected: WOODWARD RD,  Facility Carried by Structure: WOODWARD AVENUE
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 13.422,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Discuss Lakewood, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.