Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Los Molinos, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 19Number of bridges
  • 151ft / 45.6mTotal length
  • $674,000Total costs
  • 67,420Total average daily traffic
  • 8,378Total average daily truck traffic
  • 75,588Total future (year 2040) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Los Molinos
  • No street view available for this location

New bridges in Los Molinos, CA - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11910-1919
  • 31920-1929
  • 11930-1939
  • 11940-1949
  • 21950-1959
  • 21960-1969
  • 31970-1979
  • 11980-1989
  • 11990-1999
  • 22000-2009
  • 12010-2019
Reconstructed bridges in Los Molinos, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11930-1939
  • 31940-1949
  • 11950-1959
Average Bridge Daily Traffic in Los Molinos, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 85.7%Good
  • 14.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 64.3%Good
  • 35.7%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 57.1%Good
  • 7.1%Satisfactory
  • 21.4%Fair
  • 14.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 21.1%Very good
  • 36.8%Good
  • 36.8%Satisfactory
  • 5.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 20.0%Good
  • 60.0%Satisfactory
  • 20.0%Poor
Find on map >>   Show street view

Structure Number: 8 0006,  Location: 02-TEH-099-9.14 (Lat: 39.984522,  Lng: -122.081217),  Route carried "on" structure: State highway 99,  Year Built: 1918,  Year Reconstructed: 1952,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 6,800 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,086 (year 2040),  Features Intersected: CHAMPLIN SLOUGH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.140,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 83.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8 0008,  Location: 02-TEH-099-13.96 (Lat: 40.051608,  Lng: -122.100683),  Route carried "on" structure: State highway 99,  Year Built: 1921,  Year Reconstructed: 1952,  Status: Open,  Structure Length: 1.20m (3.94ft),  Average Daily Traffic: 9,300 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 8,803 (year 2040),  Features Intersected: S BR OF N FK MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.960,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.9m (19.4ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 26.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 20.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8 001,  Location: 02-TEH-099-15.55 (Lat: 40.074667,  Lng: -122.100592),  Route carried "on" structure: State highway 99,  Year Built: 1920,  Year Reconstructed: 1952,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 9,300 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 8,803 (year 2040),  Features Intersected: SUNSET CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.550,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Skew: 9 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 37.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 8 0078,  Location: 02-TEH-099-12.59 (Lat: 40.031789,  Lng: -122.099822),  Route carried "on" structure: State highway 99,  Year Built: 1900,  Year Reconstructed: 1935,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 6,800 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,086 (year 2040),  Features Intersected: LOS MOLINOS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.590,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 17.0m (55.8ft)

Condition: Channel: Good,  Culverts: Poor,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.37m (4.49ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $167,000,  Roadway Improvement Cost: $33,000,  Total Project Cost: $280,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8 016,  Location: 02-TEH-099-13.33 (Lat: 40.042597,  Lng: -122.100064),  Route carried "on" structure: State highway 99,  Year Built: 2004,  Status: Open,  Structure Length: 8.05m (26.41ft),  Average Daily Traffic: 6,800 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,086 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.330,  Lanes on structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.2m (56.4ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.0m (101.7ft),  Curb-To-Curb Width: 16.3m (53.5ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 8 0162,  Location: 02-TEH-099-16.60 (Lat: 40.089944,  Lng: -122.100539),  Route carried "on" structure: State highway 99,  Year Built: 2006,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 9,300 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 8,803 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DYE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.600,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.8m (117.5ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 8 0166,  Location: 02-TEH-099-14.05 (Lat: 40.052956,  Lng: -122.100658),  Route carried "on" structure: State highway 99,  Year Built: 2014,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 9,300 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 8,600 (year 2040),  Design Load: HL 93,  Features Intersected: N BRANCH N FORK MILL CRK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.050,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 8C0049,  Location: 0.1 MI SOUTH OF TAFT STR (Lat: 40.045594,  Lng: -122.095058),  Route carried "on" structure: County highway ,  Year Built: 1940,  Year Reconstructed: 1958,  Status: Posted for load-capacity,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 200 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 316 (year 2040),  Features Intersected: MILL CREEK,  Facility Carried by Structure: SHERWOOD BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 6.3m (20.7ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 28.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Critical Feature Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 8C005,  Location: 0.3 MI S WILSON STREET (Lat: 40.049908,  Lng: -122.091172),  Route carried "on" structure: County highway ,  Year Built: 1939,  Status: Posted for load,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 150 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 267 (year 2040),  Features Intersected: NORTH FORK MILL CREEK,  Facility Carried by Structure: SHASTA BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 5.7m (18.7ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 15.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 9.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Other Special Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8C0075,  Location: 0.8 MI W OF SH 99 (Lat: 40.028464,  Lng: -122.114453),  Route carried "on" structure: County highway ,  Year Built: 1958,  Status: Open,  Structure Length: 2.85m (9.35ft),  Average Daily Traffic: 2,000 (year 2006),  Truck Traffic: 8%,  Average Future Daily Traffic: 3,186 (year 2042),  Design Load: HS 20,  Features Intersected: SACRAMENTO RIV OVERFLOW,  Facility Carried by Structure: ARAMAYO WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 8C008,  Location: 0.6 MI W OF SH 99 (Lat: 40.028267,  Lng: -122.112344),  Route carried "on" structure: County highway ,  Year Built: 1958,  Status: Open,  Structure Length: 2.85m (9.35ft),  Average Daily Traffic: 3,300 (year 2006),  Truck Traffic: 8%,  Average Future Daily Traffic: 5,273 (year 2040),  Design Load: HS 20,  Features Intersected: SACRAMENTO RIV OVERFLOW,  Facility Carried by Structure: ARAMAYO WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Fair,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8C0106,  Location: 0.3 MI W TEHAMA VINA RD (Lat: 40.018269,  Lng: -122.086272),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 200 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 322 (year 2042),  Features Intersected: CHAMPLIN SLOUGH,  Facility Carried by Structure: LINCOLN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 5.9m (19.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.85m (2.79ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Critical Feature Inspection Date: Febuary 2022,  Bridge Improvement Cost: $51,000,  Roadway Improvement Cost: $23,000,  Total Project Cost: $197,000 ( Estimate for 2017),  Deck Structure Type: Closed Grating,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8C0276,  Location: 0.3 MI W TEHAMA VINA ROAD (Lat: 40.018269,  Lng: -122.088325),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 500 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 806 (year 2042),  Features Intersected: CHAMPLIN SLOUGH,  Facility Carried by Structure: LINCOLN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 5.9m (19.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.85m (2.79ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Critical Feature Inspection Date: Febuary 2022,  Bridge Improvement Cost: $51,000,  Roadway Improvement Cost: $23,000,  Total Project Cost: $197,000 ( Estimate for 2017),  Deck Structure Type: Closed Grating,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8C0277,  Location: 0.4 MI W TEHAMA VINA ROAD (Lat: 40.015372,  Lng: -122.086014),  Route carried "on" structure: County highway ,  Year Built: 1974,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 400 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 663 (year 2044),  Features Intersected: CHAMPLIN SLOUGH,  Facility Carried by Structure: LEE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8C0278,  Location: 0.1 MI WEST OF RIVER AVE (Lat: 40.029347,  Lng: -122.114897),  Route carried "on" structure: County highway ,  Year Built: 1921,  Status: Open,  Structure Length: 6.04m (19.82ft),  Average Daily Traffic: 1,000 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,110 (year 2040),  Features Intersected: SACRAMENTO RIV OVERFLOW,  Facility Carried by Structure: TEHAMA VINA ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 4.9m (16.1ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 26.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8C0297,  Location: 0.2 MI N TEHAMA VINA RD (Lat: 40.032858,  Lng: -122.096383),  Route carried "on" structure: County highway ,  Year Built: 1970,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 970 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,555 (year 2040),  Features Intersected: LOS MOLINOS CREEK,  Facility Carried by Structure: SHERWOOD BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8C0298,  Location: 0.3 MI N TEHAMA VINA RD (Lat: 40.033522,  Lng: -122.093500),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 300 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 497 (year 2044),  Features Intersected: LOS MOLINOS CREEK,  Facility Carried by Structure: BUENA VISTA AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 82.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8C0347,  Location: 0.60 MI E OF SH 99 (Lat: 40.012033,  Lng: -122.084497),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 400 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 663 (year 2044),  Features Intersected: CHAMPLIN SLOUGH,  Facility Carried by Structure: SHERMAN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.5m (14.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 8C0349,  Location: 0.7 MI E OF S.H. 99 (Lat: 40.027303,  Lng: -122.087533),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 400 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 663 (year 2044),  Design Load: HS 20,  Features Intersected: CHAMPLIN SLOUGH,  Facility Carried by Structure: TEHAMA-VINA RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.9m (29.2ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Los Molinos, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.