Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Lowell, Arkansas (AR)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 34Number of bridges
  • 312ft / 94.7mTotal length
  • 821,079Total average daily traffic
  • 69,954Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Lowell
  • No street view available for this location

New bridges in Lowell, AR - historical statistics
  • New bridges - historical statistics
  • 11950-1959
  • 151980-1989
  • 21990-1999
  • 12000-2009
  • 42010-2019
  • 12020-2022
Average Bridge Daily Traffic in Lowell, AR
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Excellent
  • 75.0%Good
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 37.5%Excellent
  • 62.5%Good
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 25.0%Excellent
  • 62.5%Very good
  • 12.5%Good
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 6.3%Excellent
  • 37.5%Very good
  • 56.3%Good
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 6.3%Very good
  • 31.3%Good
  • 62.5%Satisfactory
Find on map >>   Show street view

Structure Number: 5949,  Location: .72 MI W US 71B (Lat: 36.254431,  Lng: -94.150881),  Route carried "on" structure: State highway 264,  Year Built: 1982,  Status: Open,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 26,000 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 33,600 (year 2034),  Design Load: HS 20,  Features Intersected: I 49
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.175,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5954,  Location: .75 MI N SH 264 (Lat: 36.265411,  Lng: -94.149781),  Route carried "on" structure: City street 41960,  Year Built: 1982,  Status: Open,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 141 (year 1987),  Truck Traffic: 1%,  Average Future Daily Traffic: 76 (year 2007),  Design Load: HS 20,  Features Intersected: I-49,  Facility Carried by Structure: OAKWOOD Benton 1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.110,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5955,  Location: 2.05 MI N SH 264 (Lat: 36.283539,  Lng: -94.157181),  Route carried "on" structure: City street 45800,  Year Built: 1982,  Status: Open,  Structure Length: 9.72m (31.89ft),  Average Daily Traffic: 37,748 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 9,872 (year 2025),  Design Load: HS 20,  Features Intersected: I-49,  Facility Carried by Structure: PG Rd. BENTON 1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.446,  Lanes on structure: 6,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.1m (102.0ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 22.9m (75.1ft),  Out-to-Out Width: 27.9m (91.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 7313,  Location: 0.04 Mi. SE of I-49 (Lat: 36.239344,  Lng: -94.154744),  Route carried "on" structure: Ramp US 612,  Year Built: 2018,  Status: Open,  Structure Length: 12.65m (41.50ft),  Average Daily Traffic: 10 (year 2017),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,000 (year 2014),  Design Load: HL 93,  Features Intersected: Silent Grove Rd.
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 7.854,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 36.9m (121.1ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7315,  Location: 0.02 Mi. NW of I-49 (Lat: 36.240969,  Lng: -94.155611),  Route carried "on" structure: Ramp State highway 612,  Year Built: 2018,  Status: Open,  Structure Length: 7.16m (23.49ft),  Average Daily Traffic: 15,250 (year 2014),  Truck Traffic: 12%,  Average Future Daily Traffic: 37,000 (year 2034),  Design Load: HL 93,  Features Intersected: Goad Springs Rd.
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 7.017,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.6m (41.3ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.8m (101.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7333,  Location: 1.56 NE of Lowell (Lat: 36.275489,  Lng: -94.119431),  Route carried "on" structure: State highway 265,  Year Built: 2017,  Status: Not yet open,  Structure Length: 20.49m (67.22ft),  Average Daily Traffic: 680 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 16,500 (year 2035),  Design Load: HL 93,  Features Intersected: Dogwood Dr.
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 7.805,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 45.7m (149.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 14.1m (46.3ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Good,  Superstructure: Excellent,  Substructure: Very good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 20711,  Location: .5 MI EAST OF US 71 (Lat: 36.248867,  Lng: -94.116656),  Route carried "on" structure: City street 265,  Year Built: 1989,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 9,600 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,500 (year 2035),  Design Load: H 20,  Features Intersected: CREEK,  Facility Carried by Structure: S.Old Wire Rd.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.042,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 23104,  Location: .3 MI N JCT APPLE BLOSSUM (Lat: 36.241817,  Lng: -94.143242),  Route carried "on" structure: City street 30965,  Year Built: 1994,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 555 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 35 (year 2020),  Features Intersected: BRANCH,  Facility Carried by Structure: Lowell. KINKADE PL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.225,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 23105,  Location: .3 MI. N. SH 264 (Lat: 36.256775,  Lng: -94.147053),  Route carried "on" structure: City street 33600,  Year Built: 2006,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 200 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 282 (year 2027),  Features Intersected: Branch,  Facility Carried by Structure: Lowell. Links Dr.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.4m (7.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 23106,  Location: 0.1MI N JCT SH 264 (Lat: 36.255694,  Lng: -94.145736),  Route carried "on" structure: City street 16062,  Year Built: 1994,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 700 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 987 (year 2020),  Features Intersected: PUPPY CREEK,  Facility Carried by Structure: LowellN DIXIELAND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.161,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 3.4m (11.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.8m (5.9ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 23725,  Location: 0.1M S JCT W ROBINSON AVE (Lat: 36.259850,  Lng: -94.140569),  Route carried "on" structure: City street 12430,  Year Built: 2014,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,275 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 125 (year 2034),  Features Intersected: BRANCH,  Facility Carried by Structure: COLUMBIA PL Lowell
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.209,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 24171,  Location: .3 MI N JCT APPLE BLOSSUM (Lat: 36.241764,  Lng: -94.142408),  Route carried "on" structure: City street ,  Year Built: 2021,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 11,000 (year 2019),  Average Future Daily Traffic: 13,200 (year 2040),  Features Intersected: Branch,  Facility Carried by Structure: S. Dixieland Rd.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.193,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 2.4m (7.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 24.7m (81.0ft)

Condition: Channel: Excellent,  Culverts: Very good,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: A5948,  Location: 2.74 MI N WASH CO LINE (Lat: 36.240500,  Lng: -94.155211),  Route carried "on" structure: Interstate 49,  Year Built: 1982,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 39,500 (year 2018),  Truck Traffic: 11%,  Average Future Daily Traffic: 52,000 (year 2033),  Design Load: HS 20,  Features Intersected: GOAD SPRINGS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 123.839,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.4m (57.1ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: B5948,  Location: 2.73 MI N WASH CO LINE (Lat: 36.240319,  Lng: -94.155100),  Route carried "on" structure: Interstate 49,  Year Built: 1982,  Status: Open,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 39,500 (year 2018),  Truck Traffic: 11%,  Average Future Daily Traffic: 52,000 (year 2033),  Design Load: HS 20,  Features Intersected: GOAD SPRINGS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 123.807,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.4m (57.1ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: X0503,  Location: .72 MI S SH 264 (Lat: 36.244081,  Lng: -94.151839),  Route carried "on" structure: Interstate 49,  Year Built: 1982,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 79,000 (year 2018),  Truck Traffic: 11%,  Average Future Daily Traffic: 104,000 (year 2033),  Features Intersected: CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 124.306,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: X0504,  Location: .26 MI SO SH 264 (Lat: 36.250669,  Lng: -94.150361),  Route carried "on" structure: Interstate 49,  Year Built: 1982,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 79,000 (year 2018),  Truck Traffic: 11%,  Average Future Daily Traffic: 104,000 (year 2033),  Design Load: H 20,  Features Intersected: PUPPY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 125.046,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 44.8m (147.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.6m (15.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: X0505,  Location: .06 MI SO SH 264 (Lat: 36.253511,  Lng: -94.147839),  Route carried "on" structure: ServiceInterstate 49,  Year Built: 1982,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 53 (year 2014),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,100 (year 2028),  Design Load: H 20,  Features Intersected: DITCH,  Facility Carried by Structure: S 6th Plac Benton2
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 125.448,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: X0506,  Location: .65 MI W US 71B (Lat: 36.254419,  Lng: -94.147678),  Route carried "on" structure: State highway 264,  Year Built: 1982,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 26,000 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 33,600 (year 2034),  Design Load: H 20,  Features Intersected: PUPPY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.046,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: X0507,  Location: .01 MI N SH 264 (Lat: 36.254850,  Lng: -94.147369),  Route carried "on" structure: ServiceInterstate 49,  Year Built: 1982,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 53 (year 2014),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,100 (year 2028),  Design Load: H 20,  Features Intersected: DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 125.513,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2018
Find on map >>   Show street view

Structure Number: X0508,  Location: .21 MI N SH 264 (Lat: 36.256639,  Lng: -94.150239),  Route carried "on" structure: Interstate 49,  Year Built: 1982,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 79,000 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 115,000 (year 2033),  Design Load: H 20,  Features Intersected: DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 125.802,  Lanes on structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 47.9m (157.2ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 29.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: X0509,  Location: 1.2 MI N SH 264 (Lat: 36.271781,  Lng: -94.149969),  Route carried "on" structure: Interstate 49,  Year Built: 1982,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 79,000 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 115,000 (year 2033),  Design Load: H 20,  Features Intersected: DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 127.396,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: X0712,  Location: 3.49 MI W JCT 71 & 264 (Lat: 36.259050,  Lng: -94.193869),  Route carried "on" structure: State highway 264,  Year Built: 1952,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 10,596 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 7,616 (year 2028),  Design Load: H 20,  Features Intersected: CROSS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.472,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: X0767,  Location: .48 MI W JCT 71B&264 (Lat: 36.254361,  Lng: -94.146669),  Route carried "on" structure: State highway 264,  Year Built: 1989,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 25,109 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 33,600 (year 2034),  Design Load: H 20,  Features Intersected: PUPPY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.885,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.4m (11.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: X0768,  Location: 0.22 MI W JCT US71B & 264 (Lat: 36.254200,  Lng: -94.140900),  Route carried "on" structure: State highway 264,  Year Built: 1989,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 25,109 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 28,206 (year 2028),  Design Load: H 20,  Features Intersected: PUPPY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.354,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 5949,  Location: .72 MI W US 71B (Lat: 36.254431,  Lng: -94.150881),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 39,000 (year 2014),  Truck Traffic: 1%,  Features Intersected: I 49,  Facility Carried by Structure: SH 264 Benton 2
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 125.464,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 5949,  Location: .72 MI W US 71B (Lat: 36.254431,  Lng: -94.150881),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 39,000 (year 2014),  Truck Traffic: 1%,  Features Intersected: I 49,  Facility Carried by Structure: SH 264 Benton 2
Minimum Vertical Clearance: 4.96m (16.27ft),  Kilometerpoint: 125.464,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 5954,  Location: .75 MI N SH 264 (Lat: 36.265411,  Lng: -94.149781),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 39,000 (year 2014),  Truck Traffic: 12%,  Features Intersected: I-49,  Facility Carried by Structure: OAKWOOD Benton 1
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 125.835,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 5954,  Location: .75 MI N SH 264 (Lat: 36.265411,  Lng: -94.149781),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 39,000 (year 2014),  Truck Traffic: 12%,  Features Intersected: I-49,  Facility Carried by Structure: OAKWOOD Benton 1
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 125.835,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 5955,  Location: 2.05 MI N SH 264 (Lat: 36.283539,  Lng: -94.157181),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 39,500 (year 2014),  Truck Traffic: 12%,  Features Intersected: I-49 NB Lanes,  Facility Carried by Structure: PG Rd. BENTON 1
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 128.828,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 5955,  Location: 2.05 MI N SH 264 (Lat: 36.283539,  Lng: -94.157181),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 39,500 (year 2014),  Truck Traffic: 12%,  Features Intersected: I-49 SB Lanes,  Facility Carried by Structure: PG Rd. BENTON 1
Minimum Vertical Clearance: 4.96m (16.27ft),  Kilometerpoint: 128.828,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 7315,  Location: 0.02 Mi. NW of I-49 (Lat: 36.240969,  Lng: -94.155611),  Route carried "under" structure: Ramp City street ,  Structure Length: 0. m,  Features Intersected: S. Goad Springs St.,  Facility Carried by Structure: SH 612 NW ramp
Minimum Vertical Clearance: 30.17m (98.98ft),  Kilometerpoint: 7.017,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 7333,  Location: 1.56 NE of Lowell (Lat: 36.275489,  Lng: -94.119431),  Route carried "under" structure: County highway 622,  Structure Length: 0. m,  Features Intersected: CR 622 / Dogwood Drive,  Facility Carried by Structure: SH 265
Minimum Vertical Clearance: 21.42m (70.28ft),  Kilometerpoint: 0.000,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: A5948,  Location: 2.74 MI N WASH CO LINE (Lat: 36.240500,  Lng: -94.155211),  Route carried "under" structure: County highway 240,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 1986),  Truck Traffic: 1%,  Features Intersected: GOAD SPRING RD,  Facility Carried by Structure: I-49, SB Benton 1
Minimum Vertical Clearance: 7.01m (23.00ft),  Kilometerpoint: 4.394,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: B5948,  Location: 2.73 MI N WASH CO LINE (Lat: 36.240319,  Lng: -94.155100),  Route carried "under" structure: County highway 240,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 1986),  Truck Traffic: 1%,  Features Intersected: GOAD SPRING RD,  Facility Carried by Structure: I-49 NB Benton 1
Minimum Vertical Clearance: 5.45m (17.88ft),  Kilometerpoint: 4.394,  Length of Maximum Span: 0.0m

Discuss Lowell, Arkansas (AR) on our hugely popular Arkansas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.