Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Magnolia, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 19Number of bridges
  • 108ft / 33.2mTotal length
  • 155,860Total average daily traffic
  • 30,520Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Magnolia
  • No street view available for this location

New bridges in Magnolia, NC - historical statistics
  • New bridges - historical statistics
  • 31950-1959
  • 121980-1989
  • 31990-1999
  • 12010-2019
Average Bridge Daily Traffic in Magnolia, NC
Average Bridge Truck Traffic in Magnolia, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 33.3%Very good
  • 50.0%Satisfactory
  • 16.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 16.7%Very good
  • 66.7%Good
  • 16.7%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 33.3%Very good
  • 66.7%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 20.0%Good
  • 20.0%Satisfactory
  • 60.0%Fair
Find on map >>   Show street view

Structure Number: 610006,  Location: 0.5 MI W JCT SR1909 (Lat: 34.911350,  Lng: -78.034850),  Route carried "on" structure: State highway 903,  Year Built: 1994,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 3,800 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: MAXWELL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 74.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 57.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: July 2021,  Underwater Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 610015,  Location: 1.5 MI. S. JCT. SR1114 (Lat: 34.909119,  Lng: -78.100706),  Route carried "on" structure: State highway 1107,  Year Built: 1994,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 680 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,360 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: MILLERS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2021,  Underwater Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 610067,  Location: 0.4 MI E.JCT SR1911 (Lat: 34.895386,  Lng: -78.021097),  Route carried "on" structure: State highway 1912,  Year Built: 2012,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 480 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 960 (year 2040),  Design Load: HL 93,  Features Intersected: MAXWELL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 49.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 61007,  Location: .9 MI.S. OF JCT. SR1922 (Lat: 34.903381,  Lng: -77.988897),  Route carried "on" structure: State highway 1921,  Year Built: 1992,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 100 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ELDER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 71.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 610406,  Location: 0.6 MI E JCT SR1923 (Lat: 34.911600,  Lng: -77.991058),  Route carried "on" structure: State highway 1922,  Year Built: 1956,  Status: Posted for load,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 210 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 420 (year 2040),  Features Intersected: ELDER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.1m (16.7ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 28.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 610431,  Location: 0.2 MI.W.JCT.SR1921 (Lat: 34.892708,  Lng: -78.004061),  Route carried "on" structure: State highway 1912,  Year Built: 1986,  Status: Open,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 480 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 960 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.4m (76.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 610432,  Location: 0.7 MI.E.SR1909 (Lat: 34.902794,  Lng: -78.012283),  Route carried "on" structure: State highway 1922,  Year Built: 1986,  Status: Open,  Structure Length: 5.97m (19.59ft),  Average Daily Traffic: 210 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 420 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.8m (61.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 610433,  Location: 0.4 MI.N.SR1909 (Lat: 34.917728,  Lng: -78.024519),  Route carried "on" structure: State highway 903,  Year Built: 1987,  Status: Open,  Structure Length: 5.91m (19.39ft),  Average Daily Traffic: 4,000 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 8,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.5m (60.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 610434,  Location: 0.4 MI. S. JCT. SR1909 (Lat: 34.935444,  Lng: -78.050408),  Route carried "on" structure: State highway 1908,  Year Built: 1986,  Status: Open,  Structure Length: 6.09m (19.98ft),  Average Daily Traffic: 400 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 230025,  Location: .22 MI.S.JCT.SR2013 (Lat: 35.719208,  Lng: -81.694044),  Route carried "under" structure: Interstate 40,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 26,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: US64
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 31.410,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 17.0m (55.8ft)

Find on map >>   Show street view

Structure Number: 230025,  Location: .22 MI.S.JCT.SR2013 (Lat: 35.719208,  Lng: -81.694044),  Route carried "under" structure: Interstate 40,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 26,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: US64
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 31.410,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 17.0m (55.8ft)

Find on map >>   Show street view

Structure Number: 610431,  Location: 0.2 MI.W.JCT.SR1921 (Lat: 34.892708,  Lng: -78.004061),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 11,000 (year 2018),  Truck Traffic: 23%,  Features Intersected: SR1912
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 113.691,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.4m (76.8ft)

Find on map >>   Show street view

Structure Number: 610431,  Location: 0.2 MI.W.JCT.SR1921 (Lat: 34.892708,  Lng: -78.004061),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 11,000 (year 2018),  Truck Traffic: 23%,  Features Intersected: SR1912
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 113.691,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.4m (76.8ft)

Find on map >>   Show street view

Structure Number: 610432,  Location: 0.7 MI.E.SR1909 (Lat: 34.902794,  Lng: -78.012283),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 10,750 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1922
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 113.386,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Find on map >>   Show street view

Structure Number: 610432,  Location: 0.7 MI.E.SR1909 (Lat: 34.902794,  Lng: -78.012283),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 10,750 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1922
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 113.386,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Find on map >>   Show street view

Structure Number: 610433,  Location: 0.4 MI.N.SR1909 (Lat: 34.917728,  Lng: -78.024519),  Route carried "under" structure: Interstate 40,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2019),  Truck Traffic: 23%,  Features Intersected: NC903
Minimum Vertical Clearance: 5.24m (17.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 610433,  Location: 0.4 MI.N.SR1909 (Lat: 34.917728,  Lng: -78.024519),  Route carried "under" structure: Interstate 40,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2019),  Truck Traffic: 23%,  Features Intersected: NC903
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 610434,  Location: 0.4 MI. S. JCT. SR1909 (Lat: 34.935444,  Lng: -78.050408),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1908
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 113.082,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 610434,  Location: 0.4 MI. S. JCT. SR1909 (Lat: 34.935444,  Lng: -78.050408),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1908
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 113.082,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Discuss Magnolia, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.