Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Mayfield Heights, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 26Number of bridges
  • 276ft / 83.5mTotal length
  • 1,179,248Total average daily traffic
  • 101,577Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Mayfield Heights
  • No street view available for this location

New bridges in Mayfield Heights, OH - historical statistics
  • New bridges - historical statistics
  • 181960-1969
  • 81990-1999
Reconstructed bridges in Mayfield Heights, OH - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21980-1989
  • 41990-1999
Average Bridge Daily Traffic in Mayfield Heights, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Very good
  • 33.3%Good
  • 41.7%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 58.3%Very good
  • 41.7%Good
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 25.0%Very good
  • 41.7%Good
  • 33.3%Satisfactory
Find on map >>   Show street view

Structure Number: 1811525,  Location: 1.26 MI. S. OF JCT US-322 (Lat: 41.508919,  Lng: -81.463289),  Route carried "on" structure: County highway C0020,  Year Built: 1963,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 13.14m (43.11ft),  Average Daily Traffic: 13,032 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 18,088 (year 2035),  Design Load: H 20,  Features Intersected: IR271&271X (LANDER),  Facility Carried by Structure: LANDER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.609,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 1811584,  Location: .41 MI. S. OF JCT. US-322 (Lat: 41.515069,  Lng: -81.449589),  Route carried "on" structure: Interstate 271,  Year Built: 1963,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 64,977 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 90,188 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: MARSOL RD @ MP 34.5
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.503,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1811592,  Location: 0.41 MI. S. OF JCT US 322 (Lat: 41.514861,  Lng: -81.449350),  Route carried "on" structure: Interstate 271X,  Year Built: 1994,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 64,977 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 90,188 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: MARSOL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.503,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1811606,  Location: 0.41 MI. S. OF JCT US 322 (Lat: 41.514769,  Lng: -81.449281),  Route carried "on" structure: Interstate 271X,  Year Built: 1994,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 64,977 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 90,188 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: MARSOL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.503,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1811614,  Location: .41 MI. S. OF JCT. US-322 (Lat: 41.514711,  Lng: -81.448889),  Route carried "on" structure: Interstate 271,  Year Built: 1963,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 64,977 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 90,188 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: MARSOL RD @ MP 34.5
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.503,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1811649,  Location: JCT. US-322 WITH I-27 (Lat: 41.519800,  Lng: -81.445781),  Route carried "on" structure: Ramp Interstate 271,  Year Built: 1961,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 39,660 (year 1988),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,048 (year 2008),  Design Load: HS 20+Mod,  Features Intersected: USR 322 (1340) @ MP 34.9
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.163,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 1811673,  Location: JCT. US-322 WITH I-271 (Lat: 41.519769,  Lng: -81.445581),  Route carried "on" structure: Interstate 271,  Year Built: 1963,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 49,428 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 68,606 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: USR 322 (1341) @ MP 34.9
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.163,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1811681,  Location: 3.5 MI S. OF CUY/LAK LINE (Lat: 41.519789,  Lng: -81.445269),  Route carried "on" structure: Interstate 271X,  Year Built: 1994,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 49,428 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 68,606 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: USR 322 (MAYFIELD RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.163,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1811703,  Location: JCT. US-322 WITH I-271 (Lat: 41.519789,  Lng: -81.444781),  Route carried "on" structure: Interstate 271,  Year Built: 1963,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 49,428 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 68,606 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: USR 322 (1345) @ MP 34.9
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.163,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1811711,  Location: 3.5 MI S. OF CUY/LAK LINE (Lat: 41.519789,  Lng: -81.445061),  Route carried "on" structure: Interstate 271X,  Year Built: 1994,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 49,428 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 68,606 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: USR 322 (MAYFIELD RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.163,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1811738,  Location: JCT. US-322 WITH I-271 (Lat: 41.519789,  Lng: -81.444539),  Route carried "on" structure: Ramp Interstate 271,  Year Built: 1961,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 39,660 (year 1988),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,048 (year 2008),  Design Load: HS 20+Mod,  Features Intersected: USR 322 (1346) @ MP 34.9
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.163,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 1811762,  Location: .75 MI. N. OF JCT. US-322 (Lat: 41.530461,  Lng: -81.447269),  Route carried "on" structure: County highway C0054,  Year Built: 1963,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 12.25m (40.19ft),  Average Daily Traffic: 9,462 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,133 (year 2035),  Design Load: H 15,  Features Intersected: IR271&271X (RIDGEBURY),  Facility Carried by Structure: RIDGEBURY BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.609,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1811525,  Location: 1.26 MI. S. OF JCT US-322 (Lat: 41.508919,  Lng: -81.463289),  Route carried "under" structure: Interstate 271,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 129,954 (year 2015),  Truck Traffic: 9%,  Features Intersected: CR-20 (Lander Rd),  Facility Carried by Structure: LANDER RD
Minimum Vertical Clearance: 5.04m (16.54ft),  Kilometerpoint: 19.135,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 1811525,  Location: 1.26 MI. S. OF JCT US-322 (Lat: 41.508919,  Lng: -81.463289),  Route carried "under" structure: Interstate 271X,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 113,670 (year 2010),  Truck Traffic: 11%,  Features Intersected: CR-20 (Lander Rd),  Facility Carried by Structure: LANDER RD
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 19.135,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 1811584,  Location: .41 MI. S. OF JCT. US-322 (Lat: 41.515069,  Lng: -81.449589),  Route carried "under" structure: City street MSLRD,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 1970),  Features Intersected: I-271,  Facility Carried by Structure: IR 271 S.B
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>   Show street view

Structure Number: 1811592,  Location: 0.41 MI. S. OF JCT US 322 (Lat: 41.514861,  Lng: -81.449350),  Route carried "under" structure: City street MSLRD,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 1970),  Features Intersected: IR-271X,  Facility Carried by Structure: IR 271X SB
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>   Show street view

Structure Number: 1811606,  Location: 0.41 MI. S. OF JCT US 322 (Lat: 41.514769,  Lng: -81.449281),  Route carried "under" structure: City street MSLRD,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 1970),  Features Intersected: IR-271X,  Facility Carried by Structure: IR 271X NB
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>   Show street view

Structure Number: 1811614,  Location: .41 MI. S. OF JCT. US-322 (Lat: 41.514711,  Lng: -81.448889),  Route carried "under" structure: City street MSLRD,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 1970),  Features Intersected: I-271,  Facility Carried by Structure: IR 271 N.B.
Minimum Vertical Clearance: 4.32m (14.17ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>   Show street view

Structure Number: 1811649,  Location: JCT. US-322 WITH I-27 (Lat: 41.519800,  Lng: -81.445781),  Route carried "under" structure: US 322,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 26,582 (year 2010),  Truck Traffic: 3%,  Features Intersected: I-271 SB RAMP (1315W),  Facility Carried by Structure: RAMP WEST OF I-271
Minimum Vertical Clearance: 4.74m (15.55ft),  Kilometerpoint: 21.565,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 1811673,  Location: JCT. US-322 WITH I-271 (Lat: 41.519769,  Lng: -81.445581),  Route carried "under" structure: US 322,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 26,582 (year 2010),  Truck Traffic: 3%,  Features Intersected: I-271 SB (CUY-271-1315L),  Facility Carried by Structure: IR 271 S.B
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 21.581,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 1811681,  Location: 3.5 MI S. OF CUY/LAK LINE (Lat: 41.519789,  Lng: -81.445269),  Route carried "under" structure: US 322,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 26,582 (year 2010),  Truck Traffic: 3%,  Features Intersected: IR-271X,  Facility Carried by Structure: IR 271X SB
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 21.597,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 1811703,  Location: JCT. US-322 WITH I-271 (Lat: 41.519789,  Lng: -81.444781),  Route carried "under" structure: US 322,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 26,582 (year 2010),  Truck Traffic: 3%,  Features Intersected: I-271 NB (CUY-271-1315R),  Facility Carried by Structure: IR 271 N.B
Minimum Vertical Clearance: 6.22m (20.41ft),  Kilometerpoint: 21.646,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 1811711,  Location: 3.5 MI S. OF CUY/LAK LINE (Lat: 41.519789,  Lng: -81.445061),  Route carried "under" structure: US 322,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 26,582 (year 2010),  Truck Traffic: 3%,  Features Intersected: IR-271X,  Facility Carried by Structure: IR 271X NB
Minimum Vertical Clearance: 5.74m (18.83ft),  Kilometerpoint: 21.613,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 1811738,  Location: JCT. US-322 WITH I-271 (Lat: 41.519789,  Lng: -81.444539),  Route carried "under" structure: US 322,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 28,120 (year 2010),  Truck Traffic: 4%,  Features Intersected: I-271 NB RAMP (1315E),  Facility Carried by Structure: RAMP EAST OF I-271
Minimum Vertical Clearance: 6.81m (22.34ft),  Kilometerpoint: 21.662,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 1811762,  Location: .75 MI. N. OF JCT. US-322 (Lat: 41.530461,  Lng: -81.447269),  Route carried "under" structure: Interstate 271X,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 107,380 (year 2010),  Truck Traffic: 11%,  Features Intersected: CR-54 (Ridgebury Blvd.),  Facility Carried by Structure: RIDGEBURY BLVD.
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 22.370,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 1811762,  Location: .75 MI. N. OF JCT. US-322 (Lat: 41.530461,  Lng: -81.447269),  Route carried "under" structure: Interstate 271,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 107,380 (year 2010),  Truck Traffic: 11%,  Features Intersected: CR-54 (Ridgebury Blvd),  Facility Carried by Structure: RIDGEBURY BLVD.
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 22.370,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.9m (75.1ft)

Discuss Mayfield Heights, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.