Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Meadow, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 108ft / 32.5mTotal length
  • 75,483Total average daily traffic
  • 23,933Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Meadow
  • No street view available for this location

Average Bridge Daily Traffic in Meadow, UT
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 60.0%Good
  • 40.0%Satisfactory
Find on map >>   Show street view

Structure Number: C 435,  Location: 1.9 MI.SO.MEADOW INTERCHG (Lat: 38.873633,  Lng: -112.436617),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 10.44m (34.25ft),  Average Daily Traffic: 500 (year 2020),  Average Future Daily Traffic: 1,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-15 (SR-15) NBL & SBL,  Facility Carried by Structure: CO.RD.SO.OF MEADOW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.499,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 39.4m (129.3ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1F 259,  Location: MEADOW INTERCHANGE (Lat: 38.893297,  Lng: -112.411883),  Route carried "on" structure: Interstate 15,  Year Built: 1972,  Status: Open,  Structure Length: 5.57m (18.27ft),  Average Daily Traffic: 14,411 (year 2020),  Truck Traffic: 32%,  Average Future Daily Traffic: 18,014 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-133, INTCHG. X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 255.155,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.3m (40.4ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1F 287,  Location: 0.7 MI.SO.MEADOW INTERCHG (Lat: 38.885664,  Lng: -112.421108),  Route carried "on" structure: Interstate 15,  Year Built: 1973,  Status: Open,  Structure Length: 5.46m (17.91ft),  Average Daily Traffic: 14,411 (year 2020),  Truck Traffic: 32%,  Average Future Daily Traffic: 18,014 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CO. RD. WEST FROM MEADOW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 253.990,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.3m (40.4ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 34.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3F 259,  Location: MEADOW INTERCHANGE (Lat: 38.894111,  Lng: -112.411397),  Route carried "on" structure: Interstate 15,  Year Built: 1972,  Status: Open,  Structure Length: 5.57m (18.27ft),  Average Daily Traffic: 14,411 (year 2020),  Truck Traffic: 32%,  Average Future Daily Traffic: 18,014 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-133, INTCHG. X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 255.046,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.3m (40.4ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3F 287,  Location: 0.7 MI.SO.MEADOW INTERCHG (Lat: 38.886142,  Lng: -112.421039),  Route carried "on" structure: Interstate 15,  Year Built: 1973,  Status: Open,  Structure Length: 5.46m (17.91ft),  Average Daily Traffic: 14,411 (year 2020),  Truck Traffic: 32%,  Average Future Daily Traffic: 18,014 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CO. RD. WEST FROM MEADOW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 253.829,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.3m (40.4ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 34.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: C 435,  Location: 1.9 MI.SO.MEADOW INTERCHG (Lat: 38.873633,  Lng: -112.436617),  Route carried "under" structure: Interstate 15,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 14,411 (year 2020),  Truck Traffic: 32%,  Features Intersected: I-15 (SR-15) NBL & SBL,  Facility Carried by Structure: CO.RD.SO.OF MEADOW
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 251.858,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.4m (129.3ft)

Find on map >>   Show street view

Structure Number: 1F 259,  Location: MEADOW INTERCHANGE (Lat: 38.893297,  Lng: -112.411883),  Route carried "under" structure: State highway 133,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 1,464 (year 2020),  Truck Traffic: 30%,  Features Intersected: SR-133, INTCHG. X-ROAD,  Facility Carried by Structure: I-15 (SR-15) NBL
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 11.439,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 1F 287,  Location: 0.7 MI.SO.MEADOW INTERCHG (Lat: 38.885664,  Lng: -112.421108),  Route carried "under" structure: County highway ,  Year Built: 1973,  Structure Length: 0. m,  Features Intersected: CO. RD. WEST FROM MEADOW,  Facility Carried by Structure: I-15 (SR-15) NBL
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.6m (74.1ft)

Find on map >>   Show street view

Structure Number: 3F 259,  Location: MEADOW INTERCHANGE (Lat: 38.894111,  Lng: -112.411397),  Route carried "under" structure: State highway 133,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 1,464 (year 2020),  Truck Traffic: 30%,  Features Intersected: SR-133, INTCHG. X-ROAD,  Facility Carried by Structure: I-15 (SR-15) SBL
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 11.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 3F 287,  Location: 0.7 MI.SO.MEADOW INTERCHG (Lat: 38.886142,  Lng: -112.421039),  Route carried "under" structure: County highway ,  Year Built: 1973,  Structure Length: 0. m,  Features Intersected: CO. RD. WEST FROM MEADOW,  Facility Carried by Structure: I-15 (SR-15) SBL
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.6m (74.1ft)

Discuss Meadow, Utah (UT) on our hugely popular Utah forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.