Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Negley, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 115ft / 35.2mTotal length
  • $50,000Total costs
  • 12,279Total average daily traffic
  • 1,287Total average daily truck traffic
  • 16,668Total future (year 2035) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Negley
  • No street view available for this location

New bridges in Negley, OH - historical statistics
  • New bridges - historical statistics
  • 2Before 1900
  • 11910-1919
  • 11920-1929
  • 21930-1939
  • 11950-1959
  • 21990-1999
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Negley, OH - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 31980-1989
  • 11990-1999
  • 12000-2009
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 40.0%Very good
  • 40.0%Good
  • 20.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 10.0%Excellent
  • 30.0%Very good
  • 10.0%Good
  • 50.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 50.0%Very good
  • 20.0%Good
  • 30.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 63.6%Very good
  • 18.2%Good
  • 18.2%Satisfactory
Find on map >>   Show street view

Structure Number: 1503731,  Location: 0.4 M W of SR 170 (Lat: 40.789269,  Lng: -80.552589),  Route carried "on" structure: State highway 154,  Year Built: 2014,  Status: Open,  Structure Length: 6.35m (20.83ft),  Average Daily Traffic: 2,000 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,400 (year 2035),  Design Load: HL 93,  Features Intersected: OVER BULL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.595,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.8m (35.4ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.3m (66.6ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Very good,  Channel: Very good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1503766,  Location: 2.2 MI. W OF PENNA ST LN (Lat: 40.789450,  Lng: -80.549019),  Route carried "on" structure: State highway 154,  Year Built: 1993,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 1,785 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 2,478 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: LESLIE RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.917,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1503782,  Location: 1.12 MI W OF PENNA ST LN (Lat: 40.787100,  Lng: -80.530600),  Route carried "on" structure: State highway 154,  Year Built: 1933,  Year Reconstructed: 1985,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 1,156 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 1,605 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: NORTH FK LITTLE BEAVER C
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.623,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1504487,  Location: 1.41 MI S OF SR 154 (Lat: 40.770669,  Lng: -80.547589),  Route carried "on" structure: State highway 170,  Year Built: 2006,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 2,244 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,115 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: BR LITTLE BEAVER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.723,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 68.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 1504533,  Location: .15 MI S OF SR 154 (Lat: 40.787350,  Lng: -80.544881),  Route carried "on" structure: State highway 170,  Year Built: 1929,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 3,042 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,222 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: BULL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.751,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1530291,  Location: 0.2 MI E SR170 (Lat: 40.775131,  Lng: -80.543111),  Route carried "on" structure: County highway T1026,  Year Built: 1882,  Year Reconstructed: 2002,  Status: Posted for load,  Structure Length: 4.88m (16.01ft),  Average Daily Traffic: 305 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 423 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: LITTLE BEAVER CREEK,  Facility Carried by Structure: CARMEL ACHOR 1026
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.897,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.5m (155.8ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 4.5m (14.8ft),  Out-to-Out Width: 4.8m (15.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 4.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 3.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Critical Feature Inspection Date: August 2020,  Deck Structure Type: Open Grating
Find on map >>   Show street view

Structure Number: 1533347,  Location: 0.0 MI W SR 170 (Lat: 40.791211,  Lng: -80.549131),  Route carried "on" structure: County highway C0432,  Year Built: 1994,  Status: Open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 489 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 679 (year 2035),  Design Load: HS 20,  Features Intersected: LITTLE RUN,  Facility Carried by Structure: BYE RD 432
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.451,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1537962,  Location: 0.0 MI W SR170 (Lat: 40.801339,  Lng: -80.549050),  Route carried "on" structure: County highway T0955,  Year Built: 1911,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 91 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 126 (year 2035),  Design Load: HS 20,  Features Intersected: LITTLE RUN,  Facility Carried by Structure: CARBON HILL RD 955
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.692,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.52m (4.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Roadway Improvement Cost: $4,000,  Total Project Cost: $50,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1538136,  Location: 0.7 MI E SR154 (Lat: 40.793189,  Lng: -80.521781),  Route carried "on" structure: County highway T1024,  Year Built: 1959,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 915 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,270 (year 2035),  Features Intersected: NO NAME,  Facility Carried by Structure: DARLINGTON RD 1024
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.724,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Very good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1538179,  Location: 0.0 MI N SR154 (Lat: 40.792350,  Lng: -80.564311),  Route carried "on" structure: County highway T1025,  Year Built: 1930,  Year Reconstructed: 1981,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 96 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 133 (year 2035),  Design Load: HS 20,  Features Intersected: LITTLE BULL CREEK,  Facility Carried by Structure: PIONEER RD 1025
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.435,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.2m (20.3ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Deck Structure Type: Open Grating
Find on map >>   Show street view

Structure Number: 1538209,  Location: 1.5 MI E SR170 (Lat: 40.753519,  Lng: -80.539111),  Route carried "on" structure: County highway T1031,  Year Built: 1893,  Year Reconstructed: 2008,  Status: Posted for load,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 156 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 217 (year 2035),  Features Intersected: NORTH FORK LITTLE BEAVER,  Facility Carried by Structure: PANCAKE-CLARK.1031
Minimum Vertical Clearance: 6.71m (22.01ft),  Kilometerpoint: 3.492,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 43.9m (144.0ft),  Curb-To-Curb Width: 3.9m (12.8ft),  Out-to-Out Width: 4.3m (14.1ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Very good,  Operating Rating: 5.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 4.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Critical Feature Inspection Date: August 2020,  Deck Structure Type: Open Grating
Discuss Negley, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.