Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Obetz, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 22Number of bridges
  • 377ft / 115mTotal length
  • 492,235Total average daily traffic
  • 56,496Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Obetz
  • No street view available for this location

New bridges in Obetz, OH - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 21950-1959
  • 11960-1969
  • 141970-1979
  • 11980-1989
  • 32010-2019
Reconstructed bridges in Obetz, OH - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 01980-1989
  • 61990-1999
Average Bridge Daily Traffic in Obetz, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.1%Very good
  • 78.6%Good
  • 7.1%Satisfactory
  • 7.1%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 28.6%Very good
  • 57.1%Good
  • 7.1%Satisfactory
  • 7.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 21.4%Very good
  • 64.3%Good
  • 7.1%Satisfactory
  • 7.1%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 60.0%Very good
  • 20.0%Satisfactory
  • 20.0%Fair
Find on map >>   Show street view

Structure Number: 2513595,  Location: 4.77 MI S OF US33 (Lat: 39.872739,  Lng: -82.969331),  Route carried "on" structure: County highway C0013,  Year Built: 1970,  Status: Open,  Structure Length: 8.60m (28.22ft),  Average Daily Traffic: 7,771 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 84,936 (year 2035),  Design Load: H 20,  Features Intersected: IR 270,  Facility Carried by Structure: LOCKBOURNE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.0m (82.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Cathodic Protection
Find on map >>   Show street view

Structure Number: 2513625,  Location: 4.24 MI S OF US33 (Lat: 39.872411,  Lng: -82.959631),  Route carried "on" structure: Interstate 270,  Year Built: 1970,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 30,597 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 42,469 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER CSX RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 81.063,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2513684,  Location: 4.2J MI S OF US 33 (Lat: 39.872161,  Lng: -82.959550),  Route carried "on" structure: Interstate 270,  Year Built: 1970,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 30,597 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 42,469 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER CSX RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 81.063,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2513714,  Location: 3.76 MI S OF US 33 (Lat: 39.872011,  Lng: -82.950800),  Route carried "on" structure: Interstate 270,  Year Built: 1970,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 30,597 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 42,469 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER NS RR / OBETZ RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 80.290,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2513749,  Location: 3.76 MI S OF US33 (Lat: 39.871739,  Lng: -82.950831),  Route carried "on" structure: Interstate 270,  Year Built: 1970,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 30,597 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 42,469 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER NS RR / OBETZ RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 80.290,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2513773,  Location: 3.80 MI S OF US33 (Lat: 39.871461,  Lng: -82.941589),  Route carried "on" structure: City street M0007,  Year Built: 1970,  Status: Open,  Structure Length: 11.47m (37.63ft),  Average Daily Traffic: 6,400 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 84,936 (year 2035),  Design Load: H 20,  Features Intersected: IR 270,  Facility Carried by Structure: GROVEPORT RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 34.1m (111.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 2513862,  Location: 2.87 MI S OF US33 (Lat: 39.871500,  Lng: -82.933750),  Route carried "on" structure: County highway C0122,  Year Built: 1970,  Status: Open,  Structure Length: 11.55m (37.89ft),  Average Daily Traffic: 22,125 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 84,936 (year 2035),  Design Load: HS 20,  Features Intersected: IR 270,  Facility Carried by Structure: ALUM CREEK DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 2513897,  Location: 2.85 MI S OF US33 (Lat: 39.871519,  Lng: -82.933539),  Route carried "on" structure: County highway C0122,  Year Built: 1970,  Status: Open,  Structure Length: 11.55m (37.89ft),  Average Daily Traffic: 22,125 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 84,936 (year 2035),  Design Load: HS 20,  Features Intersected: IR 270,  Facility Carried by Structure: ALUM CREEK DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 2530325,  Location: AT BIXBY RD (Lat: 39.856200,  Lng: -82.938331),  Route carried "on" structure: County highway C0122,  Year Built: 1959,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 8.90m (29.20ft),  Average Daily Traffic: 8,164 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 11,332 (year 2035),  Design Load: H 20,  Features Intersected: BIG WALNUT(ALUM CREEK DR,  Facility Carried by Structure: ALUM CREEK DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.009,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 84.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 2530333,  Location: AT BIXBY RD (Lat: 39.856419,  Lng: -82.938511),  Route carried "on" structure: County highway C0122,  Year Built: 1959,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 8.90m (29.20ft),  Average Daily Traffic: 8,164 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 11,332 (year 2035),  Design Load: H 20,  Features Intersected: BIG WALNUT(ALUM CREEK DR,  Facility Carried by Structure: ALUM CREEK DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.993,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 84.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 253074,  Location: .15 MI EAST OF ALUM CR DR (Lat: 39.866919,  Lng: -82.931700),  Route carried "on" structure: County highway C0007,  Year Built: 1964,  Status: Open,  Structure Length: 8.38m (27.49ft),  Average Daily Traffic: 8,962 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 12,439 (year 2035),  Design Load: HS 20,  Features Intersected: BIG WALNUT (GROVEPORT),  Facility Carried by Structure: GROVEPORT RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.725,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 2531933,  Location: 0.23 MI SOUTH OF RATHMELL (Lat: 39.856689,  Lng: -82.957100),  Route carried "on" structure: County highway C0131,  Year Built: 1909,  Year Reconstructed: 1974,  Status: Open,  Structure Length: 6.80m (22.31ft),  Average Daily Traffic: 1,397 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,939 (year 2035),  Design Load: HS 20,  Features Intersected: BIG WALNUT CR(REESE RD),  Facility Carried by Structure: REESE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.370,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.7m (81.0ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2532352,  Location: SOUTH OF 270 (Lat: 39.867161,  Lng: -82.935931),  Route carried "on" structure: County highway C0007,  Year Built: 2013,  Status: Open,  Structure Length: 6.55m (21.49ft),  Average Daily Traffic: 8,108 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,254 (year 2035),  Design Load: HL 93,  Features Intersected: ALUM CRK DR(GROVEPORT RD,  Facility Carried by Structure: GROVEPORT RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.483,  Lanes on structure: 4,  Lanes under structure: 9,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.4m (103.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2535033,  Location: 0.1 MI EAST OF BIXBY RD (Lat: 39.845711,  Lng: -82.953219),  Route carried "on" structure: County highway C0235,  Year Built: 1988,  Status: Open,  Structure Length: 9.66m (31.69ft),  Average Daily Traffic: 2,798 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 3,884 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CSX & NS RR (ROHR),  Facility Carried by Structure: ROHR RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.545,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 17.4m (57.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2536048,  Location: E RAMP TO GROVEPORT BYPAS (Lat: 39.866811,  Lng: -82.933661),  Route carried "on" structure: County highway C0007,  Year Built: 2013,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 8,962 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 12,439 (year 2035),  Design Load: HL 93,  Features Intersected: BOEHM DITCH(GROVEPORT RD,  Facility Carried by Structure: GROVEPORT RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.660,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 23 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 68.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 2513595,  Location: 4.77 MI S OF US33 (Lat: 39.872739,  Lng: -82.969331),  Route carried "under" structure: Interstate 270,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 61,193 (year 2015),  Truck Traffic: 13%,  Features Intersected: UNDER LOCKBOURNE RD,  Facility Carried by Structure: LOCKBOURNE RD
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 81.916,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.0m (82.0ft)

Find on map >>   Show street view

Structure Number: 2513714,  Location: 3.76 MI S OF US 33 (Lat: 39.872011,  Lng: -82.950800),  Route carried "under" structure: County highway 246,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 1,886 (year 2015),  Truck Traffic: 5%,  Features Intersected: I-270 WB(OVER N&W OBETZ,  Facility Carried by Structure: IR 270
Minimum Vertical Clearance: 6.83m (22.41ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.8m (55.1ft)

Find on map >>   Show street view

Structure Number: 2513749,  Location: 3.76 MI S OF US33 (Lat: 39.871739,  Lng: -82.950831),  Route carried "under" structure: County highway 246,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 1,886 (year 2015),  Truck Traffic: 5%,  Features Intersected: I-270 EB(OV N&W OBETZ RD,  Facility Carried by Structure: IR 270
Minimum Vertical Clearance: 7.01m (23.00ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.8m (55.1ft)

Find on map >>   Show street view

Structure Number: 2513773,  Location: 3.80 MI S OF US33 (Lat: 39.871461,  Lng: -82.941589),  Route carried "under" structure: Interstate 270,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 61,193 (year 2015),  Truck Traffic: 13%,  Features Intersected: UNDER GROVEPORT RD,  Facility Carried by Structure: GROVEPORT RD
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 79.550,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 2513862,  Location: 2.87 MI S OF US33 (Lat: 39.871500,  Lng: -82.933750),  Route carried "under" structure: Interstate 270,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 61,193 (year 2015),  Truck Traffic: 13%,  Features Intersected: UNDER ALUM CREEK DRIVE S,  Facility Carried by Structure: ALUM CREEK DR
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 78.858,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.0m (128.0ft)

Find on map >>   Show street view

Structure Number: 2513897,  Location: 2.85 MI S OF US33 (Lat: 39.871519,  Lng: -82.933539),  Route carried "under" structure: Interstate 270,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 61,193 (year 2015),  Truck Traffic: 13%,  Features Intersected: UNDER ALUM CREEK DRIVE N,  Facility Carried by Structure: ALUM CREEK DR
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 78.826,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.0m (128.0ft)

Find on map >>   Show street view

Structure Number: 2532352,  Location: SOUTH OF 270 (Lat: 39.867161,  Lng: -82.935931),  Route carried "under" structure: County highway C0122,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 16,327 (year 2015),  Truck Traffic: 7%,  Features Intersected: ALUM CRK DR(GROVEPORT RD,  Facility Carried by Structure: GROVEPORT RD
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 42.165,  Lanes on structure: 4,  Lanes under structure: 9,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Discuss Obetz, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.