Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Palmer, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 36ft / 11.1mTotal length
  • $175,000Total costs
  • 13,790Total average daily traffic
  • 1,578Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Palmer
  • No street view available for this location

New bridges in Palmer, MI - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 21960-1969
  • 11970-1979
  • 31980-1989
  • 12000-2009
  • 22010-2019
  • 12020-2022
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 50.0%Very good
  • 33.3%Good
  • 16.7%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 50.0%Very good
  • 50.0%Good
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 50.0%Very good
  • 33.3%Good
  • 16.7%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 10.0%Excellent
  • 40.0%Very good
  • 40.0%Good
  • 10.0%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Excellent
  • 50.0%Very good
  • 25.0%Serious
Find on map >>   Show street view

Structure Number: 6483,  Location: 3.0 MI SE PALMER (Lat: 46.400425,  Lng: -87.551306),  Route carried "on" structure: State highway 35,  Year Built: 1986,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 1,146 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 1,256 (year 2018),  Design Load: HS 20,  Features Intersected: SWEITZERS CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 46.214,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 156,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 20.9m (68.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 88.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 52.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6484,  Location: 2 MI SE OF PALMER (Lat: 46.411572,  Lng: -87.562158),  Route carried "on" structure: State highway 35,  Year Built: 1984,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 1,146 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 1,256 (year 2018),  Design Load: HS 20,  Features Intersected: WARNER CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 47.820,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 156,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6485,  Location: IN PALMER (Lat: 46.436800,  Lng: -87.595000),  Route carried "on" structure: State highway 35,  Year Built: 1986,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 2,505 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 2,565 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: WARNER CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 53.237,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 156,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6486,  Location: IN PALMER (Lat: 46.444000,  Lng: -87.593500),  Route carried "on" structure: State highway 35,  Year Built: 1965,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 2,505 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 2,565 (year 2018),  Design Load: H 20,  Features Intersected: WARNER CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 52.349,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 156,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 649,  Location: 0.9 MI N OF PALMER (Lat: 46.451386,  Lng: -87.588044),  Route carried "on" structure: State highway 35,  Year Built: 1964,  Status: Open,  Structure Length: 0.65m (2.13ft),  Average Daily Traffic: 2,505 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 2,565 (year 2018),  Features Intersected: BR WARNER CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 54.187,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 156,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 1.8m (5.9ft),  Out-to-Out Width: 33.5m (109.9ft)

Condition: Channel: Poor,  Culverts: Serious,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.37m (1.21ft),  Designated Inspection Frequency: Every 18 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $23,000,  Roadway Improvement Cost: $2,000,  Total Project Cost: $26,000 ( Estimate for 2050)
Find on map >>   Show street view

Structure Number: 6491,  Location: 1.3 MI NE OF PALMER (Lat: 46.455217,  Lng: -87.577128),  Route carried "on" structure: State highway 35,  Year Built: 2015,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 2,725 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,175 (year 2035),  Design Load: Greater than HL93,  Features Intersected: BR WARNER CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 54.966,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 156,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.5m (21.3ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 83.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 64.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6536,  Location: 3 MILES SOUTH OF PALMER (Lat: 46.406767,  Lng: -87.593614),  Route carried "on" structure: County highway ,  Year Built: 2021,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 62 (year 2019),  Average Future Daily Traffic: 80 (year 2039),  Design Load: Greater than HL93,  Features Intersected: SCHWEITZER CREEK,  Facility Carried by Structure: COUNTY RD 565
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.282,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Excellent,  Culverts: Excellent,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 0.95m (3.12ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $64,000,  Roadway Improvement Cost: $6,000,  Total Project Cost: $75,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6608,  Location: 2.4 MI S OF PALMER (Lat: 46.406619,  Lng: -87.587050),  Route carried "on" structure: County highway ,  Year Built: 1935,  Status: Posted for load,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 10 (year 2001),  Average Future Daily Traffic: 20 (year 1998),  Design Load: HS 20+Mod,  Features Intersected: SCHWEITZERS CREEK,  Facility Carried by Structure: MWC ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.430,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.8m (15.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.5m (14.8ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 13.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 10.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of replacement,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.95m (3.12ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $63,000,  Roadway Improvement Cost: $6,000,  Total Project Cost: $74,000 ( Estimate for 2050),  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 6609,  Location: 3.5 SE OF PALMER (Lat: 46.402483,  Lng: -87.544506),  Route carried "on" structure: County highway ,  Year Built: 2015,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 20 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 30 (year 2034),  Design Load: Greater than HL93,  Features Intersected: WARNER CREEK,  Facility Carried by Structure: MK ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.041,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6613,  Location: 3 MI SW OF PALMER (Lat: 46.411083,  Lng: -87.624261),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 20 (year 2005),  Average Future Daily Traffic: 30 (year 2024),  Design Load: HS 20+Mod,  Features Intersected: SCHWEITZERS CREEK,  Facility Carried by Structure: PFSROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.814,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6494,  Location: 0.5 MI S OF PALMER (Lat: 46.422128,  Lng: -87.582767),  Route carried "under" structure: State highway 35,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 1,146 (year 2007),  Truck Traffic: 14%,  Features Intersected: M-35,  Facility Carried by Structure: TILDEN PIPELINE
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 49.858,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 30.4m (99.7ft)

Discuss Palmer, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.