  • National Bridge Inventory (NBI) Statistics
  • 21Number of bridges
  • 246ft / 75.3mTotal length
  • $2,584,000Total costs
  • 101,906Total average daily traffic
  • 6,837Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Penrose
  • No street view available for this location

New bridges in Penrose, CO - historical statistics
  • New bridges - historical statistics
  • 51920-1929
  • 41940-1949
  • 61970-1979
  • 21990-1999
  • 32000-2009
  • 12010-2019
Average Bridge Daily Traffic in Penrose, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 12.5%Very good
  • 25.0%Good
  • 43.8%Satisfactory
  • 18.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 6.3%Very good
  • 25.0%Good
  • 56.3%Satisfactory
  • 6.3%Fair
  • 6.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 37.5%Good
  • 37.5%Satisfactory
  • 25.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 26.3%Very good
  • 31.6%Good
  • 31.6%Satisfactory
  • 10.5%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Good
  • 50.0%Satisfactory
  • 25.0%Fair
Find on map >>   Show street view

Structure Number: FRCO 120-211,  Location: 3.5 MI E OF PORTLAND (Lat: 38.374272,  Lng: -104.963697),  Route carried "on" structure: County highway ,  Year Built: 1923,  Status: Posted for load-capacity,  Structure Length: 3.17m (10.40ft),  Average Daily Traffic: 56 (year 2018),  Average Future Daily Traffic: 80 (year 2038),  Design Load: HS 20,  Features Intersected: BEAVER CREEK,  Facility Carried by Structure: CR 120/PORTLAND RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.316,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.6m (97.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 6.2m (20.3ft),  Out-to-Out Width: 6.6m (21.7ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 19.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 11.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2021,  Critical Feature Inspection Date: Febuary 2021,  Bridge Improvement Cost: $1,704,000,  Roadway Improvement Cost: $170,000,  Total Project Cost: $1,874,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: FRCO 120-212,  Location: 3 MI E OF PORTLAND (Lat: 38.376564,  Lng: -104.967631),  Route carried "on" structure: County highway ,  Year Built: 1923,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 51 (year 2018),  Average Future Daily Traffic: 72 (year 2038),  Features Intersected: RANGER CREEK,  Facility Carried by Structure: CR120/OLD PORTLAND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.874,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 6.2m (20.3ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: FRCO 123-213,  Location: .5 MI W OF A STREET (Lat: 38.446778,  Lng: -105.055733),  Route carried "on" structure: County highway ,  Year Built: 1928,  Year Reconstructed: 1975,  Status: Open,  Structure Length: 1.84m (6.04ft),  Average Daily Traffic: 684 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 978 (year 2038),  Features Intersected: BRUSH HOLLOW CREEK,  Facility Carried by Structure: CR123 (3RD STREET)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.031,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.3m (27.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 37.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: FRCO 123-214A,  Location: 0.7 MI E OF CR 67 (Lat: 38.460908,  Lng: -105.100047),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 1.59m (5.22ft),  Average Daily Traffic: 688 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 984 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: EIGHT MILE CREEK,  Facility Carried by Structure: COUNTY ROAD 123
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.464,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: FRCO 132-108A,  Location: 1.6 MI NE OF CR 123 (Lat: 38.472486,  Lng: -105.091756),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 257 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 367 (year 2038),  Design Load: HS 20,  Features Intersected: EIGHT MILE CREEK,  Facility Carried by Structure: COUNTY ROAD 132
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.580,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.5m (57.4ft),  Curb-To-Curb Width: 5.6m (18.4ft),  Out-to-Out Width: 6.2m (20.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 1.92m (6.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $472,000,  Roadway Improvement Cost: $47,000,  Total Project Cost: $709,000 ( Estimate for 2019),  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: K-16-AL,  Location: 0.3 MI E OF PORTLAND (Lat: 38.388250,  Lng: -105.015989),  Route carried "on" structure: State highway 120A,  Year Built: 2014,  Status: Open,  Structure Length: 12.56m (41.21ft),  Average Daily Traffic: 190 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 230 (year 2040),  Design Load: HL 93,  Features Intersected: RR, ARKANSAS RIVER,  Facility Carried by Structure: SH 120 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.829,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: K-16-AM,  Location: 2.8 MI E JCT SH 115 (Lat: 38.393122,  Lng: -105.030589),  Route carried "on" structure: State highway 120A,  Year Built: 2009,  Status: Open,  Structure Length: 7.27m (23.85ft),  Average Daily Traffic: 800 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 984 (year 2040),  Design Load: HL 93,  Features Intersected: HARDSCRABBLE CREEK,  Facility Carried by Structure: SH 120 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.348,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: K-16-C,  Location: 7.5 MI W OF JCT SH 120 (Lat: 38.433092,  Lng: -105.096619),  Route carried "on" structure: US 50A,  Year Built: 1949,  Status: Open,  Structure Length: 5.31m (17.42ft),  Average Daily Traffic: 7,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 7,910 (year 2040),  Design Load: H 20,  Features Intersected: EIGHT MILE CREEK,  Facility Carried by Structure: US 50 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 408.645,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 31.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: K-16-CC,  Location: 2.9 MI E OF JCT SH 120 (Lat: 38.418178,  Lng: -105.042247),  Route carried "on" structure: State highway 115A,  Year Built: 1973,  Status: Open,  Structure Length: 7.59m (24.90ft),  Average Daily Traffic: 4,500 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,860 (year 2040),  Design Load: HS 20,  Features Intersected: US 50 ML,  Facility Carried by Structure: SH 115 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.262,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.9m (121.1ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: K-16-CD,  Location: 1.0 MI E OF JCT SH 67 (Lat: 38.432717,  Lng: -105.096578),  Route carried "on" structure: US 50A,  Year Built: 1976,  Status: Open,  Structure Length: 5.53m (18.14ft),  Average Daily Traffic: 7,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 7,910 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: EIGHT MILE CREEK,  Facility Carried by Structure: US 50 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 408.661,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: K-16-CE,  Location: 3.4 MI E OF JCT SH 67 (Lat: 38.421683,  Lng: -105.054311),  Route carried "on" structure: US 50A,  Year Built: 1976,  Status: Open,  Structure Length: 4.24m (13.91ft),  Average Daily Traffic: 7,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 7,910 (year 2040),  Design Load: HS 20,  Features Intersected: BRUSH HOLLOW CREEK,  Facility Carried by Structure: US 50 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 412.546,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 20.0m (65.6ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: K-16-CH,  Location: 2.9 MI N OF PENROSE (Lat: 38.468928,  Lng: -104.990186),  Route carried "on" structure: State highway 115A,  Year Built: 2002,  Status: Open,  Structure Length: 4.87m (15.98ft),  Average Daily Traffic: 8,900 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 10,413 (year 2040),  Design Load: HL 93,  Features Intersected: BEAVER CREEK,  Facility Carried by Structure: SH 115 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.085,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: K-16-D,  Location: 5.1 MI W OF JCT SH 120 (Lat: 38.421961,  Lng: -105.054300),  Route carried "on" structure: US 50A,  Year Built: 1949,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 7,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 7,910 (year 2040),  Design Load: H 20,  Features Intersected: BRUSH HOLLOW CREEK,  Facility Carried by Structure: US 50 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 412.536,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.5m (54.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 35.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: K-16-E,  Location: 5.9 MI E OF JCT SH 67 S (Lat: 38.410253,  Lng: -105.010481),  Route carried "on" structure: US 50A,  Year Built: 1949,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 11,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 11,990 (year 2040),  Design Load: H 20,  Features Intersected: DRAW,  Facility Carried by Structure: US 50 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 416.579,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Out-to-Out Width: 43.3m (142.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: K-16-M,  Location: 0.7 MI E OF PORTLAND (Lat: 38.388925,  Lng: -105.008864),  Route carried "on" structure: State highway 120A,  Year Built: 1925,  Status: Open,  Structure Length: 2.50m (8.20ft),  Average Daily Traffic: 190 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 230 (year 2040),  Design Load: H 15,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: SH 120 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.503,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 5.5m (18.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.2m (23.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: K-16-P,  Location: 2.2 MI S OF PENROSE (Lat: 38.402661,  Lng: -105.056958),  Route carried "on" structure: State highway 115A,  Year Built: 2006,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 4,500 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,860 (year 2040),  Features Intersected: BRUSH HOLLOW CREEK,  Facility Carried by Structure: SH 115 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.086,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 4.9m (16.1ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.41m (24.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $1,000,  Total Project Cost: $1,000
Find on map >>   Show street view

Structure Number: K-17-AE,  Location: 2.1 MI E OF FREMONT-PUEBL (Lat: 38.365550,  Lng: -104.903536),  Route carried "on" structure: US 50A,  Year Built: 1977,  Status: Open,  Structure Length: 0.96m (3.15ft),  Average Daily Traffic: 9,800 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 12,348 (year 2040),  Design Load: HS 20,  Features Intersected: FRED ROHR GULCH,  Facility Carried by Structure: US 50 ML
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 427.468,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft),  Out-to-Out Width: 46.6m (152.9ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: K-17-AF,  Location: 3.9 MI E OF JCT SH 115 (Lat: 38.397550,  Lng: -104.976717),  Route carried "on" structure: US 50A,  Year Built: 1977,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 9,300 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 10,974 (year 2040),  Design Load: HS 20,  Features Intersected: URINE CREEK,  Facility Carried by Structure: US 50 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 419.904,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 23 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.2m (13.8ft),  Out-to-Out Width: 42.7m (140.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: K-17-D,  Location: 3 MI E OF PORTLAND (Lat: 38.385889,  Lng: -104.976131),  Route carried "on" structure: State highway 120A,  Year Built: 1925,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 190 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 230 (year 2040),  Design Load: H 15,  Features Intersected: DRAW,  Facility Carried by Structure: SH 120 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.790,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.2m (23.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: K-17-H,  Location: 1.5 MI E OF JCT SH 120 (Lat: 38.377817,  Lng: -104.949869),  Route carried "on" structure: US 50A,  Year Built: 1949,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 6.32m (20.73ft),  Average Daily Traffic: 9,800 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 12,348 (year 2040),  Design Load: H 20,  Features Intersected: BEAVER CREEK,  Facility Carried by Structure: US 50 ML
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 423.109,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 30.5m (100.1ft),  Out-to-Out Width: 31.8m (104.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Very good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: K-16-CC,  Location: 2.9 MI E OF JCT SH 120 (Lat: 38.418178,  Lng: -105.042247),  Route carried "under" structure: US 50A,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2011),  Truck Traffic: 8%,  Features Intersected: US 50 ML,  Facility Carried by Structure: SH 115 ML
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 466.238,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.9m (121.1ft)