Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Poinciana, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 932ft / 284mTotal length
  • 172,805Total average daily traffic
  • 10,980Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Poinciana
  • No street view available for this location

New bridges in Poinciana, FL - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 11970-1979
  • 31980-1989
  • 21990-1999
  • 12000-2009
  • 62010-2019
Reconstructed bridges in Poinciana, FL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Poinciana, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 88.9%Good
  • 11.1%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 66.7%Good
  • 33.3%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 10.0%Excellent
  • 10.0%Very good
  • 70.0%Good
  • 10.0%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Very good
  • 33.3%Good
  • 33.3%Satisfactory
Find on map >>   Show street view

Structure Number: 16422,  Location: 1.1MI W OF MARIGOLD AVE. (Lat: 28.069472,  Lng: -81.481194),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 4,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 6,940 (year 2042),  Design Load: HS 20,  Features Intersected: CARTER'S CANAL,  Facility Carried by Structure: POINCIANA PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.130,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 23 months,  Inspection Date: June 2021,  Underwater Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 164221,  Location: 5MI S OF CYPRESS PARKWAY (Lat: 28.092283,  Lng: -81.475417),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 14,100 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 24,464 (year 2042),  Design Load: HS 20,  Features Intersected: LILY CANAL,  Facility Carried by Structure: MARIGOLD AVE.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.415,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Excellent,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Underwater Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 164222,  Location: 1.1MI W OF MARIGOLD AVE. (Lat: 28.069167,  Lng: -81.482211),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 4,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 6,940 (year 2042),  Design Load: HS 20,  Features Intersected: LAKE MARION CREEK,  Facility Carried by Structure: POINCIANA PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.014,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 164542,  Location: 0.5MI E OF MARIGOLD AVE. (Lat: 28.128408,  Lng: -81.463622),  Route carried "on" structure: City street ,  Year Built: 1970,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 4,500 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 7,808 (year 2042),  Features Intersected: FAIRWAY DITCH,  Facility Carried by Structure: WALNUT ST.
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.771,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.2m (23.6ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 84.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 920001,  Location: .3 Mi E of Polk Co.Line (Lat: 28.253194,  Lng: -81.548306),  Route carried "on" structure: US 600,  Year Built: 1934,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 15,800 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 27,413 (year 2042),  Design Load: H 15,  Features Intersected: Reedy Creek,  Facility Carried by Structure: US-92
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.568,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 47.4 metric tons,  Method Used To Determine Operating Rating: Load Testing,  Inventory Rating: 27.7 metric tons,  Method Used To Determine Inventory Rating: Load Testing,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 920174,  Location: US-17-92 - Reedy Creek (Lat: 28.262119,  Lng: -81.539189),  Route carried "on" structure: US 600,  Year Built: 2001,  Status: Open,  Structure Length: 68.07m (223.33ft),  Average Daily Traffic: 25,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 43,375 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Reedy Creek,  Facility Carried by Structure: US-17-92
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.727,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.9m (45.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 30,  Length of Maximum Span: 22.7m (74.5ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 66.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Underwater Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 920206,  Location: 4.75 Miles N of CR-580 (Lat: 28.225750,  Lng: -81.532000),  Route carried "on" structure: Other road ,  Year Built: 2015,  Status: Open,  Structure Length: 188.03m (616.90ft),  Average Daily Traffic: 501 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,001 (year 2042),  Design Load: HL 93,  Features Intersected: Reedy Creek,  Facility Carried by Structure: Poinciana Parkway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.946,  Lanes on structure: 2,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 62,  Length of Maximum Span: 30.3m (99.4ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920207,  Location: 3.1 Miles N of CR 580 (Lat: 28.189047,  Lng: -81.504528),  Route carried "on" structure: Other road ,  Year Built: 2015,  Status: Open,  Structure Length: 4.36m (14.30ft),  Average Daily Traffic: 501 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,001 (year 2035),  Design Load: HL 93,  Features Intersected: Marigold Avenue,  Facility Carried by Structure: Poinciana Pkwy
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.357,  Lanes on structure: 2,  Lanes under structure: 2,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 43.6m (143.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 920208,  Location: 0.8 Mile N of CR 580 (Lat: 28.154342,  Lng: -81.502794),  Route carried "on" structure: Other road ,  Year Built: 2015,  Status: Open,  Structure Length: 2.90m (9.51ft),  Average Daily Traffic: 501 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,001 (year 2042),  Design Load: HL 93,  Features Intersected: KOA Street,  Facility Carried by Structure: Poinciana Parkway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.201,  Lanes on structure: 2,  Lanes under structure: 2,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920209,  Location: 1.8 Miles N of CR 580 (Lat: 28.168625,  Lng: -81.503758),  Route carried "on" structure: Other road ,  Year Built: 2015,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 501 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,001 (year 2035),  Design Load: HL 93,  Features Intersected: Canal,  Facility Carried by Structure: Poinciana Parkway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.953,  Lanes on structure: 2,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 83.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 64.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Underwater Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 924152,  Location: 0.3mi S of Poinciana Blvd (Lat: 28.150456,  Lng: -81.441361),  Route carried "on" structure: County highway 531,  Year Built: 1991,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 51,500 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 89,353 (year 2042),  Design Load: HS 20,  Features Intersected: Reedy Creek,  Facility Carried by Structure: Pleasant Hill SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.954,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 7.8m (25.6ft),  Curb-To-Curb Width: 14.8m (48.6ft),  Out-to-Out Width: 15.7m (51.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 60.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Underwater Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 924176,  Location: 0.3Mi S of Poinciana Blvd (Lat: 28.150353,  Lng: -81.441303),  Route carried "on" structure: County highway 531,  Year Built: 1999,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 51,500 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 89,353 (year 2042),  Design Load: HS 20,  Features Intersected: Reedy Creek,  Facility Carried by Structure: Pleasant Hill NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.954,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 7.8m (25.6ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.5m (8.2ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 16.3m (53.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Underwater Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920207,  Location: 3.1 Miles N of CR 580 (Lat: 28.189047,  Lng: -81.504528),  Route carried "under" structure: City street ,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 200 (year 2016),  Truck Traffic: 2%,  Features Intersected: Marigold Avenue,  Facility Carried by Structure: Poinciana Pkwy
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 1.287,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.6m (143.0ft)

Find on map >>   Show street view

Structure Number: 920208,  Location: 0.8 Mile N of CR 580 (Lat: 28.154342,  Lng: -81.502794),  Route carried "under" structure: County highway ,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 201 (year 2018),  Truck Traffic: 2%,  Features Intersected: KOA Street,  Facility Carried by Structure: Poinciana Parkway
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 5.150,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Discuss Poinciana, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.