Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Radnor, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 112ft / 34.2mTotal length
  • 4,644Total average daily traffic
  • 365Total average daily truck traffic
  • 6,448Total future (year 2035) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Radnor
  • No street view available for this location

New bridges in Radnor, OH - historical statistics
  • New bridges - historical statistics
  • 11950-1959
  • 21960-1969
  • 11970-1979
  • 11980-1989
  • 41990-1999
  • 12000-2009
  • 12010-2019
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 11.1%Excellent
  • 44.4%Very good
  • 33.3%Good
  • 11.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 44.4%Excellent
  • 22.2%Very good
  • 22.2%Good
  • 11.1%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 22.2%Excellent
  • 44.4%Very good
  • 11.1%Good
  • 11.1%Satisfactory
  • 11.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 18.2%Excellent
  • 45.5%Very good
  • 27.3%Good
  • 9.1%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Very good
  • 50.0%Good
Find on map >>   Show street view

Structure Number: 2103222,  Location: 3.52 MI N OF SR 37 (Lat: 40.371389,  Lng: -83.188911),  Route carried "on" structure: State highway 257,  Year Built: 1988,  Status: Open,  Structure Length: 3.97m (13.02ft),  Average Daily Traffic: 689 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 956 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: FULTON CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.614,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 2103249,  Location: 5.44 MI N OF SR 37 (Lat: 40.398519,  Lng: -83.196769),  Route carried "on" structure: State highway 257,  Year Built: 1961,  Status: Open,  Structure Length: 2.23m (7.32ft),  Average Daily Traffic: 689 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 956 (year 2035),  Design Load: H 15,  Features Intersected: OTTAWA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.704,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.4m (27.6ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 2131064,  Location: 0.6 MI N OF SR 203 (Lat: 40.413281,  Lng: -83.163531),  Route carried "on" structure: County highway C0203,  Year Built: 1960,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 558 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 775 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: KEBLER RUN,  Facility Carried by Structure: CURTIS RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.982,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Very good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 2132753,  Location: 1 MI. W. OF SR 257 (Lat: 40.372831,  Lng: -83.207581),  Route carried "on" structure: County highway T0180,  Year Built: 1958,  Status: Open,  Structure Length: 2.56m (8.40ft),  Average Daily Traffic: 324 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 450 (year 2035),  Design Load: H 20,  Features Intersected: FULTON CREEK,  Facility Carried by Structure: FULTON CREEK RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.012,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.8m (78.1ft),  Curb-To-Curb Width: 5.3m (17.4ft),  Out-to-Out Width: 5.4m (17.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Critical Feature Inspection Date: April 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2132982,  Location: 200 FT. W. OF WATKINS RD. (Lat: 40.397419,  Lng: -83.187389),  Route carried "on" structure: County highway T0187,  Year Built: 1971,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 59 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 82 (year 2035),  Design Load: HS 20,  Features Intersected: KEBLER RUN,  Facility Carried by Structure: RIVER RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.787,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 213349,  Location: INT. WITH C.R. 183 (Lat: 40.417831,  Lng: -83.162639),  Route carried "on" structure: County highway C0203,  Year Built: 1997,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 558 (year 2018),  Truck Traffic: 8%,  Average Future Daily Traffic: 775 (year 2038),  Design Load: HS 20,  Features Intersected: BIGGERSTAFF DITCH NO 108,  Facility Carried by Structure: CURTIS RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.368,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 2133512,  Location: 0.1 MI E. OF SR 257 (Lat: 40.350169,  Lng: -83.181811),  Route carried "on" structure: County highway C0177,  Year Built: 1997,  Status: Open,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 213 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 296 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: SCIOTO RIVER,  Facility Carried by Structure: MINK STREET RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.794,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.0m (105.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Very good,  Channel: Very good,  Operating Rating: 77.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2133547,  Location: 0.4 MI. W. OF SR 257 (Lat: 40.372561,  Lng: -83.194469),  Route carried "on" structure: County highway T0180,  Year Built: 1998,  Status: Open,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 324 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 450 (year 2035),  Design Load: HS 20,  Features Intersected: FULTON CREEK,  Facility Carried by Structure: FULTON CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.426,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Excellent,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 58.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 2133555,  Location: 0.4 MI. E. OF SR 203 (Lat: 40.418111,  Lng: -83.167389),  Route carried "on" structure: County highway T0183,  Year Built: 1997,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 324 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 450 (year 2038),  Design Load: HS 20,  Features Intersected: KEBLER RUN,  Facility Carried by Structure: HOSKINS RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.532,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Wearing Surface/Protective System: Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 2134667,  Location: 0.5 MI. W. OF JCT SR 203 (Lat: 40.345689,  Lng: -83.149169),  Route carried "on" structure: County highway C0189,  Year Built: 2002,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 353 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 490 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: PRARIE RUN,  Facility Carried by Structure: LAWRENCE RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.444,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.7m (25.3ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 2136406,  Location: 0.1 MI. E. OF SR 257 (Lat: 40.383861,  Lng: -83.189811),  Route carried "on" structure: County highway C0198,  Year Built: 2010,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 553 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 768 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: SCIOTO RIVER,  Facility Carried by Structure: RADNOR RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.129,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Excellent,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Discuss Radnor, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.