Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Shady Hills, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 17Number of bridges
  • 194ft / 59.0mTotal length
  • 212,000Total average daily traffic
  • 23,540Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Shady Hills
  • No street view available for this location

New bridges in Shady Hills, FL - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 21960-1969
  • 101990-1999
  • 42000-2009
Average Bridge Daily Traffic in Shady Hills, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 30.0%Very good
  • 70.0%Good
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 10.0%Very good
  • 90.0%Good
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 40.0%Very good
  • 60.0%Good
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 66.7%Good
Find on map >>   Show street view

Structure Number: 140004,  Location: 4.7MILES NORTH OF SR-52 (Lat: 28.385147,  Lng: -82.489197),  Route carried "on" structure: US 41,  Year Built: 1939,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 12,500 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 21,688 (year 2041),  Design Load: H 15,  Features Intersected: SCOTTS CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.782,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.2m (30.2ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.7m (25.3ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 140028,  Location: 1.7MI S OF CR-578 (Lat: 28.413178,  Lng: -82.473269),  Route carried "on" structure: US 41,  Year Built: 1969,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 12,500 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 21,688 (year 2041),  Design Load: HS 20,  Features Intersected: MASARYKTOWN CANAL (C534)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.345,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 140082,  Location: 9.8 MI N SR 54 (Lat: 28.330769,  Lng: -82.552117),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 5.40m (17.72ft),  Average Daily Traffic: 15,650 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 27,153 (year 2042),  Design Load: HS 20,  Features Intersected: SR 52
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.809,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 54.0m (177.2ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 140083,  Location: 9.8 MI N of SR 54 (Lat: 28.330789,  Lng: -82.552394),  Route carried "on" structure: State highway 589,  Year Built: 2000,  Status: Open,  Structure Length: 5.40m (17.72ft),  Average Daily Traffic: 15,650 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 27,153 (year 2042),  Design Load: HS 20,  Features Intersected: SR 52
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.809,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 54.0m (177.2ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 140084,  Location: 2.9 MI N OF SR 52 (Lat: 28.371719,  Lng: -82.543214),  Route carried "on" structure: State highway 589,  Year Built: 1999,  Status: Open,  Structure Length: 4.95m (16.24ft),  Average Daily Traffic: 10,500 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 18,218 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SHADY HILLS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.550,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.8m (81.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 37.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 140085,  Location: 2.9 MI N OF SR 52 (Lat: 28.371886,  Lng: -82.543458),  Route carried "on" structure: State highway 589,  Year Built: 1999,  Status: Open,  Structure Length: 4.95m (16.24ft),  Average Daily Traffic: 10,500 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 18,218 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SHADY HILLS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.558,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.8m (81.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 37.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 140086,  Location: 4.0MI N OF SR 52 (Lat: 28.386461,  Lng: -82.536592),  Route carried "on" structure: State highway 589,  Year Built: 1999,  Status: Open,  Structure Length: 9.18m (30.12ft),  Average Daily Traffic: 3,000 (year 2016),  Truck Traffic: 9%,  Average Future Daily Traffic: 4,000 (year 2037),  Design Load: HS 20,  Features Intersected: SR 589 SCP,  Facility Carried by Structure: CALDWELL LN 32.5
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.287,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 47.6m (156.2ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 50.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 140087,  Location: 5.5 MI N OF SR 52 (Lat: 28.402131,  Lng: -82.518606),  Route carried "on" structure: County highway 589,  Year Built: 1999,  Status: Open,  Structure Length: 8.04m (26.38ft),  Average Daily Traffic: 1,000 (year 2016),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,735 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: SR 589 SCP,  Facility Carried by Structure: LAWLESS W/EB 33.7
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.2m (131.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 140088,  Location: 7.5 MI N OF SR 52 (Lat: 28.419203,  Lng: -82.491136),  Route carried "on" structure: City street 589,  Year Built: 1999,  Status: Open,  Structure Length: 10.46m (34.32ft),  Average Daily Traffic: 2,500 (year 2016),  Truck Traffic: 8%,  Average Future Daily Traffic: 3,000 (year 2037),  Design Load: HS 20,  Features Intersected: SR 589 SUNCOAST PARKWAY,  Facility Carried by Structure: W BOWMAN RD 36.1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.058,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Toll Authority,  Approaching Roadway Width: 7.2m (23.6ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 52.3m (171.6ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 73.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 144038,  Location: 0.4MI EAST OF US-41 (Lat: 28.419219,  Lng: -82.463108),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 4.53m (14.86ft),  Average Daily Traffic: 200 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 250 (year 2042),  Design Load: HS 20,  Features Intersected: MASARYKTOWN CANAL,  Facility Carried by Structure: BOWMAN RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 6.5m (21.3ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 140082,  Location: 9.8 MI N SR 54 (Lat: 28.330769,  Lng: -82.552117),  Route carried "under" structure: State highway 52,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 22,000 (year 2020),  Truck Traffic: 15%,  Features Intersected: SR 52,  Facility Carried by Structure: SR 589 NB SCP 28.5
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 15.020,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 54.0m (177.2ft)

Find on map >>   Show street view

Structure Number: 140083,  Location: 9.8 MI N of SR 54 (Lat: 28.330789,  Lng: -82.552394),  Route carried "under" structure: State highway 52,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 22,000 (year 2020),  Truck Traffic: 15%,  Features Intersected: SR 52,  Facility Carried by Structure: SR 589 SB SCP 28.5
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 14.993,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 54.0m (177.2ft)

Find on map >>   Show street view

Structure Number: 140084,  Location: 2.9 MI N OF SR 52 (Lat: 28.371719,  Lng: -82.543214),  Route carried "under" structure: County highway ,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 10,500 (year 2020),  Truck Traffic: 10%,  Features Intersected: SHADY HILLS RD,  Facility Carried by Structure: SR 589 NB SCP 31.1
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 22.550,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.8m (81.4ft)

Find on map >>   Show street view

Structure Number: 140085,  Location: 2.9 MI N OF SR 52 (Lat: 28.371886,  Lng: -82.543458),  Route carried "under" structure: County highway ,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 10,500 (year 2020),  Truck Traffic: 10%,  Features Intersected: SHADY HILLS RD,  Facility Carried by Structure: SR589 SB SCP 31.05
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 22.565,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.8m (81.4ft)

Find on map >>   Show street view

Structure Number: 140086,  Location: 4.0MI N OF SR 52 (Lat: 28.386461,  Lng: -82.536592),  Route carried "under" structure: State highway 589,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 21,000 (year 2020),  Truck Traffic: 10%,  Features Intersected: SR 589 SCP,  Facility Carried by Structure: CALDWELL LN 32.5
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 24.287,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 47.6m (156.2ft)

Find on map >>   Show street view

Structure Number: 140087,  Location: 5.5 MI N OF SR 52 (Lat: 28.402131,  Lng: -82.518606),  Route carried "under" structure: State highway 589,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 21,000 (year 2020),  Truck Traffic: 10%,  Features Intersected: SR 589 SCP,  Facility Carried by Structure: LAWLESS W/EB 33.7
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 26.760,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.2m (131.9ft)

Find on map >>   Show street view

Structure Number: 140088,  Location: 7.5 MI N OF SR 52 (Lat: 28.419203,  Lng: -82.491136),  Route carried "under" structure: State highway 589,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 21,000 (year 2020),  Truck Traffic: 10%,  Features Intersected: SR 589 SUNCOAST PARKWAY,  Facility Carried by Structure: W BOWMAN RD 36.1
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 30.058,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.3m (171.6ft)

Discuss Shady Hills, Florida (FL) on our hugely popular Florida forum.