Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Shawneeland, Virginia (VA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 66ft / 19.5mTotal length
  • $462,000Total costs
  • 29,713Total average daily traffic
  • 641Total average daily truck traffic
  • 41,197Total future (year 2040) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Shawneeland
  • No street view available for this location

New bridges in Shawneeland, VA - historical statistics
  • New bridges - historical statistics
  • 21920-1929
  • 21930-1939
  • 11950-1959
  • 11960-1969
  • 31970-1979
  • 11980-1989
  • 21990-1999
  • 12010-2019
Reconstructed bridges in Shawneeland, VA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 11970-1979
  • 01980-1989
  • 01990-1999
  • 12000-2009
  • 12010-2019
Average Bridge Daily Traffic in Shawneeland, VA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 22.2%Very good
  • 33.3%Satisfactory
  • 33.3%Fair
  • 11.1%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 22.2%Very good
  • 11.1%Good
  • 33.3%Satisfactory
  • 22.2%Fair
  • 11.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 22.2%Very good
  • 33.3%Good
  • 22.2%Satisfactory
  • 22.2%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 53.8%Very good
  • 15.4%Good
  • 30.8%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 75.0%Good
  • 25.0%Satisfactory
Find on map >>   Show street view

Structure Number: 8098,  Location: 0.18 TO 614 - 0.27 TO 615 (Lat: 39.224875,  Lng: -78.279508),  Route carried "on" structure: US 50,  Year Built: 1929,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 5,930 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,303 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HOGUE CREEK,  Facility Carried by Structure: NORTHWESTRN PK-EBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.280,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.53m (8.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $118,000,  Roadway Improvement Cost: $18,000,  Total Project Cost: $137,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 8105,  Location: 0.18 TO 614 - 0.27 TO 615 (Lat: 39.225078,  Lng: -78.279350),  Route carried "on" structure: US 50,  Year Built: 1962,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 5,930 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,303 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HOGUE CREEK,  Facility Carried by Structure: NORTHWESTRN PK-WBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.275,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Very good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $120,000,  Roadway Improvement Cost: $20,000,  Total Project Cost: $141,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 8186,  Location: 1.60 TO 611 - 1.80 TO 607 (Lat: 39.142497,  Lng: -78.379742),  Route carried "on" structure: County highway 600,  Year Built: 1953,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 1,938 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,713 (year 2040),  Design Load: H 20,  Features Intersected: PIFER RUN,  Facility Carried by Structure: BACK MOUNTAIN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.345,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 8206,  Location: 0.01 TO 50 - 2.00 TO 600 (Lat: 39.221783,  Lng: -78.276972),  Route carried "on" structure: County highway 614,  Year Built: 1981,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 4,928 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 6,840 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: GAP RUN,  Facility Carried by Structure: BACK MOUNTAIN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.218,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 70.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 8207,  Location: 0.80 TO 50 - 1.24 TO 600 (Lat: 39.214981,  Lng: -78.288272),  Route carried "on" structure: County highway 614,  Year Built: 1932,  Year Reconstructed: 1959,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 4,928 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 6,840 (year 2040),  Design Load: HS 15,  Features Intersected: HOGUE CREEK,  Facility Carried by Structure: BACK MOUNTAIN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.995,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 2.26m (7.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Bridge Improvement Cost: $67,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $75,000,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 8231,  Location: 0.10 TO 704 - 0.30 TO END (Lat: 39.260322,  Lng: -78.333664),  Route carried "on" structure: County highway 632,  Year Built: 1975,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 642 (year 2020),  Average Future Daily Traffic: 899 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BACK CREEK,  Facility Carried by Structure: SANDMINE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.481,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.7m (58.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 829,  Location: 3.30 TO 632 - 1.05 TO 683 (Lat: 39.231231,  Lng: -78.374969),  Route carried "on" structure: County highway 704,  Year Built: 1932,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 423 (year 2017),  Average Future Daily Traffic: 499 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BACK CREEK,  Facility Carried by Structure: BACK CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.985,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 71.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 8291,  Location: 1.48 TO 617 - 0.19 TO 683 (Lat: 39.217567,  Lng: -78.388922),  Route carried "on" structure: County highway 704,  Year Built: 1927,  Year Reconstructed: 1983,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 225 (year 2020),  Average Future Daily Traffic: 261 (year 2040),  Features Intersected: BACK CREEK,  Facility Carried by Structure: BACK CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.996,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.6m (15.1ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 0.94m (3.08ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $20,000,  Roadway Improvement Cost: $5,000,  Total Project Cost: $26,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8309,  Location: 0.43 END MAINT-0.01 TO817 (Lat: 39.207000,  Lng: -78.263903),  Route carried "on" structure: County highway 809,  Year Built: 1971,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 50 (year 2017),  Average Future Daily Traffic: 73 (year 2040),  Features Intersected: GAP RUN,  Facility Carried by Structure: MCFARLAND RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.700,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 6.8m (22.3ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Other Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8311,  Location: 0.25 TO 751 - 0.25 TO END (Lat: 39.261472,  Lng: -78.328192),  Route carried "on" structure: County highway 853,  Year Built: 1972,  Status: Posted for load,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 296 (year 2014),  Average Future Daily Traffic: 327 (year 2040),  Design Load: HS 20,  Features Intersected: BACK CREEK,  Facility Carried by Structure: SINKING SPRINGS LN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.383,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 35.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.95m (6.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $75,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $83,000,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 24115,  Location: 1.05 TO 753 - 0.15 TO 612 (Lat: 39.177422,  Lng: -78.340417),  Route carried "on" structure: County highway 600,  Year Built: 1994,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 4,134 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,788 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRIB HOGUE CREEK,  Facility Carried by Structure: BACK MOUNTAIN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.121,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 24624,  Location: 1.90 TO 629 - 2.31 TO 600 (Lat: 39.136289,  Lng: -78.364194),  Route carried "on" structure: County highway 608,  Year Built: 1996,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 175 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 191 (year 2040),  Design Load: HS 20,  Features Intersected: FURNACE RUN,  Facility Carried by Structure: WARDENSVILLE PIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.978,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 30655,  Location: 0.21 TO 617-1.30WV LINE (Lat: 39.201275,  Lng: -78.411267),  Route carried "on" structure: County highway 704,  Year Built: 2015,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 114 (year 2020),  Average Future Daily Traffic: 160 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BACK CREEK,  Facility Carried by Structure: BACK CREEK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.231,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Discuss Shawneeland, Virginia (VA) on our hugely popular Virginia forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.