Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Sheridan, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 15Number of bridges
  • 177ft / 53.9mTotal length
  • $5,068,000Total costs
  • 375,635Total average daily traffic
  • 16,559Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Sheridan
  • No street view available for this location

New bridges in Sheridan, CO - historical statistics
  • New bridges - historical statistics
  • 61960-1969
  • 11980-1989
  • 22000-2009
  • 62010-2019
Average Bridge Daily Traffic in Sheridan, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 10.0%Very good
  • 30.0%Good
  • 50.0%Satisfactory
  • 10.0%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 10.0%Very good
  • 70.0%Good
  • 10.0%Satisfactory
  • 10.0%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 10.0%Very good
  • 60.0%Good
  • 10.0%Satisfactory
  • 20.0%Fair
Find on map >>   Show street view

Structure Number: F-16-BC,  Location: 0.1 MI S of JCT US285 (Lat: 39.650492,  Lng: -105.025400),  Route carried "on" structure: State highway 88A,  Year Built: 1966,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 21,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,420 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: SH 88 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.971,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 24.5m (80.4ft)

Condition: Deck: Serious,  Superstructure: Poor,  Substructure: Fair,  Channel: Very good,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.78m (12.40ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $1,199,000,  Roadway Improvement Cost: $120,000,  Total Project Cost: $1,798,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: F-16-ES,  Location: IN SHERIDAN (Lat: 39.653653,  Lng: -105.005289),  Route carried "on" structure: US 285D,  Year Built: 1960,  Year Reconstructed: 1985,  Status: Open,  Structure Length: 12.53m (41.11ft),  Average Daily Traffic: 67,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 77,050 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SOUTH PLATTE RVR, RDWY,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 156.159,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 23.0m (75.5ft),  Curb-To-Curb Width: 24.7m (81.0ft),  Out-to-Out Width: 25.7m (84.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Very good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 12.53m (41.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $4,000,  Total Project Cost: $6,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: F-16-FA,  Location: IN LITTLETON (Lat: 39.573103,  Lng: -105.028786),  Route carried "on" structure: US 85B,  Year Built: 2013,  Status: Open,  Structure Length: 3.45m (11.32ft),  Average Daily Traffic: 22,000 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 27,940 (year 2040),  Design Load: HL 93,  Features Intersected: DAD CLARK GULCH,  Facility Carried by Structure: US 85 ML NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.293,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.1m (62.7ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 19.1m (62.7ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.47m (8.10ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $569,000,  Roadway Improvement Cost: $57,000,  Total Project Cost: $854,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-FU,  Location: SHERIDAN/ENGLEWOOD (Lat: 39.653000,  Lng: -105.002042),  Route carried "on" structure: US 85B,  Year Built: 1961,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 5.77m (18.93ft),  Average Daily Traffic: 61,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 73,810 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HAMPDEN AVENUE,  Facility Carried by Structure: US 85ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 35.600,  Lanes on structure: 9,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 44.5m (146.0ft),  Skew: 21 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.9m (55.4ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 0.0m,  Curb-To-Curb Width: 34.7m (113.8ft),  Out-to-Out Width: 38.3m (125.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-YG,  Location: HAMPDEN OVER FEDERAL (Lat: 39.652153,  Lng: -105.025039),  Route carried "on" structure: US 285D,  Year Built: 2012,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 31,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 35,340 (year 2040),  Design Load: HS 20,  Features Intersected: SH 88 ML (FEDERAL BLVD),  Facility Carried by Structure: US 285 ML NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 154.608,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 79.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.54m (14.90ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $803,000,  Roadway Improvement Cost: $80,000,  Total Project Cost: $1,205,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-YH,  Location: HAMPDEN OVER FEDERAL (Lat: 39.652317,  Lng: -105.025017),  Route carried "on" structure: US 285D,  Year Built: 2013,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 31,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 35,340 (year 2040),  Design Load: HS 20,  Features Intersected: SH 88 ML (FEDERAL BLVD),  Facility Carried by Structure: US 285 ML SBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 154.610,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.6m (97.1ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 81.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.54m (14.90ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $803,000,  Roadway Improvement Cost: $80,000,  Total Project Cost: $1,205,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: SHER-01-0.50-1A,  Location: .5 MI E OF S FEDERAL BLVD (Lat: 39.642500,  Lng: -105.015556),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 6.58m (21.59ft),  Average Daily Traffic: 12,227 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 14,917 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SOUTH PLATTE RIVER,  Facility Carried by Structure: OXFORD AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.191,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.5m (103.3ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 85.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: SHER-02-0.20-02,  Location: .2 MI W OF SANTA FE (Lat: 39.654394,  Lng: -105.006056),  Route carried "on" structure: City street ,  Year Built: 2017,  Status: Open,  Structure Length: 6.43m (21.10ft),  Average Daily Traffic: 1,811 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,210 (year 2041),  Design Load: HL 93,  Features Intersected: SOUTH PLATTE RIVER,  Facility Carried by Structure: HAMILTON PL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.681,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.2m (99.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other,  Deck Protection: Other Coated Reinforcing
Find on map >>   Show street view

Structure Number: SHER-03-0.90-01,  Location: JUST SOUTH OF US285 (Lat: 39.652353,  Lng: -105.033144),  Route carried "on" structure: City street ,  Year Built: 1980,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 5,444 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 6,641 (year 2041),  Design Load: HS 20,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: LOWELL BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.521,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.0m (75.5ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 51.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: SHER-07-0.10-01,  Location: JUST S OF PLATTE RIV DR (Lat: 39.650781,  Lng: -105.009747),  Route carried "on" structure: City street ,  Year Built: 2006,  Status: Open,  Structure Length: 7.51m (24.64ft),  Average Daily Traffic: 11,153 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 13,606 (year 2041),  Features Intersected: SOUTH PLATTE RIVER,  Facility Carried by Structure: RIVERPOINT PKWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.995,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.2m (118.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 63.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-ES,  Location: IN SHERIDAN (Lat: 39.653653,  Lng: -105.005289),  Route carried "under" structure: _,  Year Built: 1960,  Structure Length: 0. m,  Features Intersected: SOUTH PLATTE RVR, RDWY,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 4.19m (13.75ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.0m (75.5ft)

Find on map >>   Show street view

Structure Number: F-16-ES,  Location: IN SHERIDAN (Lat: 39.653653,  Lng: -105.005289),  Route carried "under" structure: _,  Year Built: 1960,  Structure Length: 0. m,  Features Intersected: SOUTH PLATTE RVR, RDWY,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.0m (75.5ft)

Find on map >>   Show street view

Structure Number: F-16-FU,  Location: SHERIDAN/ENGLEWOOD (Lat: 39.653000,  Lng: -105.002042),  Route carried "under" structure: US 285D,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 64,000 (year 2011),  Truck Traffic: 4%,  Features Intersected: HAMPDEN AVENUE,  Facility Carried by Structure: US 85ML
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 417.256,  Lanes on structure: 9,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.9m (55.4ft)

Find on map >>   Show street view

Structure Number: F-16-YG,  Location: HAMPDEN OVER FEDERAL (Lat: 39.652153,  Lng: -105.025039),  Route carried "under" structure: State highway 88A,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 24,000 (year 2011),  Truck Traffic: 4%,  Features Intersected: SH 88 ML (FEDERAL BLVD),  Facility Carried by Structure: US 285 ML NBND
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 9.675,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: F-16-YH,  Location: HAMPDEN OVER FEDERAL (Lat: 39.652317,  Lng: -105.025017),  Route carried "under" structure: State highway 88A,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 24,000 (year 2011),  Truck Traffic: 4%,  Features Intersected: SH 88 ML (FEDERAL BLVD),  Facility Carried by Structure: US 285 ML SBND
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 9.673,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Discuss Sheridan, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.