Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Shorewood-Tower Hills-Harbert, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 17Number of bridges
  • 148ft / 45.3mTotal length
  • $178,000Total costs
  • 318,825Total average daily traffic
  • 99,898Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Shorewood-Tower Hills-Harbert
  • No street view available for this location

New bridges in Shorewood-Tower Hills-Harbert, MI - historical statistics
  • New bridges - historical statistics
  • 131960-1969
  • 11980-1989
  • 11990-1999
  • 22000-2009
Average Bridge Daily Traffic in Shorewood-Tower Hills-Harbert, MI
Average Bridge Truck Traffic in Shorewood-Tower Hills-Harbert, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 57.1%Good
  • 42.9%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 28.6%Very good
  • 14.3%Good
  • 57.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 28.6%Very good
  • 28.6%Good
  • 42.9%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 66.7%Good
  • 33.3%Satisfactory
Find on map >>   Show street view

Structure Number: 79,  Location: 1.0 MI N OF HARBERT (Lat: 41.880025,  Lng: -86.601378),  Route carried "on" structure: Interstate 94,  Year Built: 2003,  Status: Open,  Structure Length: 5.06m (16.60ft),  Average Daily Traffic: 18,325 (year 2007),  Truck Traffic: 32%,  Average Future Daily Traffic: 25,023 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: CSX RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.719,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 136,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.2m (56.4ft),  Curb-To-Curb Width: 19.1m (62.7ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 72.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 802,  Location: 1.3 MI S OF LAKESIDE (Lat: 41.831278,  Lng: -86.668164),  Route carried "on" structure: County highway 1113,  Year Built: 1962,  Status: Open,  Structure Length: 9.85m (32.32ft),  Average Daily Traffic: 566 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 651 (year 2032),  Design Load: H 15,  Features Intersected: I-94,  Facility Carried by Structure: LAKESIDE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.944,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.4m (103.0ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 803,  Location: 1.0 MI SE OF LAKESIDE (Lat: 41.839456,  Lng: -86.653314),  Route carried "on" structure: County highway 1124,  Year Built: 1962,  Status: Open,  Structure Length: 11.53m (37.83ft),  Average Daily Traffic: 1,177 (year 1984),  Truck Traffic: 3%,  Average Future Daily Traffic: 390 (year 2030),  Design Load: H 15,  Features Intersected: I-94,  Facility Carried by Structure: WARREN WOODS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.137,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 39.5m (129.6ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 804,  Location: 1.6 MI E OF LAKESIDE (Lat: 41.849553,  Lng: -86.635225),  Route carried "on" structure: County highway ,  Year Built: 1961,  Status: Open,  Structure Length: 10.40m (34.12ft),  Average Daily Traffic: 210 (year 2010),  Average Future Daily Traffic: 240 (year 2030),  Design Load: H 15,  Features Intersected: I-94,  Facility Carried by Structure: EAST ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.709,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 35.7m (117.1ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 807,  Location: 2.0 MI NE OF HARBERT (Lat: 41.885567,  Lng: -86.600872),  Route carried "on" structure: Interstate 94,  Year Built: 1961,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 4.50m (14.76ft),  Average Daily Traffic: 18,373 (year 2007),  Truck Traffic: 32%,  Average Future Daily Traffic: 24,900 (year 2025),  Design Load: HS 20,  Features Intersected: SAWYER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.337,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 136,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 21.6m (70.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 20.6m (67.6ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 84.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 962,  Location: 3.0 MI NW OF THREE OAKS (Lat: 41.841514,  Lng: -86.622136),  Route carried "on" structure: County highway 1124,  Year Built: 1985,  Status: Open,  Structure Length: 2.37m (7.78ft),  Average Daily Traffic: 1,022 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,600 (year 2027),  Design Load: HS 20,  Features Intersected: GALIEN RIVER,  Facility Carried by Structure: WARREN WOODS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.746,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.1m (75.8ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 83.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13091,  Location: LAKE TWP SEC 35 (Lat: 41.899692,  Lng: -86.598125),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Posted for load,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 360 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 500 (year 2027),  Design Load: HS 20,  Features Intersected: CLYMER COUNTY DRAIN,  Facility Carried by Structure: BROWNTOWN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.921,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 137,  Subroute: 9),  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 23.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Length Of Structure Improvement: 1.16m (3.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $133,000,  Roadway Improvement Cost: $45,000,  Total Project Cost: $178,000,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1349,  Location: LAKE TWP SEC 35 (Lat: 41.900089,  Lng: -86.606114),  Route carried "on" structure: Federal lands road ,  Year Built: 2009,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 150 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 250 (year 2029),  Features Intersected: PAINTERVILLE CREEK,  Facility Carried by Structure: WARREN DUNES ST PK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.036,  Lanes on structure: 2,  Owner: State Park, Forest, or Reservation Agency,  Approaching Roadway Width: 6.6m (21.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 801,  Location: 0.9 MI E OF UNION PIER (Lat: 41.827967,  Lng: -86.673478),  Route carried "under" structure: Interstate 94,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 42,600 (year 2016),  Truck Traffic: 32%,  Features Intersected: I-94,  Facility Carried by Structure: UNION PIER ROAD
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 10.030,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 802,  Location: 1.3 MI S OF LAKESIDE (Lat: 41.831278,  Lng: -86.668164),  Route carried "under" structure: Interstate 94,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 42,300 (year 2016),  Truck Traffic: 32%,  Features Intersected: I-94,  Facility Carried by Structure: LAKESIDE ROAD
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 10.585,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>   Show street view

Structure Number: 803,  Location: 1.0 MI SE OF LAKESIDE (Lat: 41.839456,  Lng: -86.653314),  Route carried "under" structure: Interstate 94,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 36,200 (year 2010),  Truck Traffic: 37%,  Features Intersected: I-94,  Facility Carried by Structure: WARREN WOODS ROAD
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 12.136,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.5m (129.6ft)

Find on map >>   Show street view

Structure Number: 804,  Location: 1.6 MI E OF LAKESIDE (Lat: 41.849553,  Lng: -86.635225),  Route carried "under" structure: Interstate 94,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 36,200 (year 2010),  Truck Traffic: 37%,  Features Intersected: I-94,  Facility Carried by Structure: EAST ROAD
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 14.011,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>   Show street view

Structure Number: 805,  Location: 1.5 MI SE OF HARBERT (Lat: 41.863756,  Lng: -86.609675),  Route carried "under" structure: Interstate 94,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 36,650 (year 2007),  Truck Traffic: 32%,  Features Intersected: I-94,  Facility Carried by Structure: THREE OAKS ROAD
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 16.656,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.8m (87.9ft)

Find on map >>   Show street view

Structure Number: 806,  Location: 1.5 MI E OF HARBERT (Lat: 41.871097,  Lng: -86.601869),  Route carried "under" structure: Interstate 94,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 35,300 (year 2011),  Truck Traffic: 30%,  Features Intersected: I-94,  Facility Carried by Structure: HARBERT ROAD
Minimum Vertical Clearance: 5.64m (18.50ft),  Kilometerpoint: 17.724,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 807,  Location: 2.0 MI NE OF HARBERT (Lat: 41.885567,  Lng: -86.600872),  Route carried "under" structure: County highway 1130,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 6,323 (year 1992),  Truck Traffic: 3%,  Features Intersected: SAWYER ROAD,  Facility Carried by Structure: I-94 EB
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 2.635,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 808,  Location: 2.0 MI NE OF HARBERT (Lat: 41.885564,  Lng: -86.601236),  Route carried "under" structure: County highway 1130,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 6,323 (year 1992),  Truck Traffic: 3%,  Features Intersected: SAWYER ROAD,  Facility Carried by Structure: I-94 WB
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 2.604,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 809,  Location: 2.0 MI S OF BRIDGEMAN (Lat: 41.899636,  Lng: -86.589417),  Route carried "under" structure: Interstate 94,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 36,746 (year 2007),  Truck Traffic: 31%,  Features Intersected: I-94,  Facility Carried by Structure: BROWNTOWN ROAD
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 21.172,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Discuss Shorewood-Tower Hills-Harbert, Michigan (MI) on our hugely popular Michigan forum.