Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Sigurd, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 26Number of bridges
  • 243ft / 74.0mTotal length
  • 131,156Total average daily traffic
  • 45,951Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Sigurd
  • No street view available for this location

New bridges in Sigurd, UT - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11940-1949
  • 11950-1959
  • 221980-1989
  • 12000-2009
Reconstructed bridges in Sigurd, UT - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 11970-1979
  • 01980-1989
  • 01990-1999
  • 12000-2009
Average Bridge Daily Traffic in Sigurd, UT
Average Bridge Truck Traffic in Sigurd, UT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 54.5%Good
  • 45.5%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 18.2%Very good
  • 72.7%Good
  • 9.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 27.3%Good
  • 72.7%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Very good
  • 58.3%Good
  • 16.7%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 14.3%Very good
  • 85.7%Satisfactory
Find on map >>   Show street view

Structure Number: 41021E,  Location: 1 MILE NORTH OF VENICE (Lat: 38.814053,  Lng: -112.006581),  Route carried "on" structure: County highway 2541,  Year Built: 1947,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 0.71m (2.33ft),  Average Daily Traffic: 970 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,213 (year 2040),  Design Load: H 15,  Features Intersected: VERMILLION CANAL,  Facility Carried by Structure: COUNTY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.358,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.2m (20.3ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 22 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 41024F,  Location: 3.5 MILES SOUTH OF AURORA (Lat: 38.872728,  Lng: -111.954308),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 252 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 306 (year 2040),  Design Load: HL 93,  Features Intersected: SEVIER RIVER,  Facility Carried by Structure: COUNTY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.568,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.8m (58.4ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 22 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C 748,  Location: 5.8 MI.N.NO.RICHFIELD INT (Lat: 38.847714,  Lng: -112.007178),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 10.16m (33.33ft),  Average Daily Traffic: 500 (year 2020),  Average Future Daily Traffic: 1,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-70 (SR-70) EBL & WBL,  Facility Carried by Structure: SO.CEDAR RIDGE RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.036,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 50.3m (165.0ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 60.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 60.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C 75,  Location: IN TOWN OF SIGURD (Lat: 38.836675,  Lng: -111.967228),  Route carried "on" structure: State highway 24,  Year Built: 1988,  Status: Open,  Structure Length: 1.66m (5.45ft),  Average Daily Traffic: 1,499 (year 2020),  Truck Traffic: 20%,  Average Future Daily Traffic: 1,874 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SEVIER RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.335,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 0.0m,  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 52.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E171,  Location: 8.6 MILES NO.OF RICHFIELD (Lat: 38.865178,  Lng: -111.965853),  Route carried "on" structure: State highway 118,  Year Built: 1951,  Year Reconstructed: 1968,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 2,396 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,995 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORTH CEDAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.837,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.2m (17.1ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: E2181,  Location: ADJACENT TO SR-24 (Lat: 38.875711,  Lng: -111.959928),  Route carried "on" structure: Interstate 70,  Year Built: 1985,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 6,767 (year 2020),  Truck Traffic: 40%,  Average Future Daily Traffic: 8,459 (year 2040),  Design Load: HS 20,  Features Intersected: VERMILLION CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 79.454,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.9m (9.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 96.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: E2288,  Location: 6.3 MI.N.NO.RICHFIELD INT (Lat: 38.851811,  Lng: -111.999764),  Route carried "on" structure: Interstate 70,  Year Built: 1988,  Status: Open,  Structure Length: 0.92m (3.02ft),  Average Daily Traffic: 9,548 (year 2020),  Truck Traffic: 38%,  Average Future Daily Traffic: 11,935 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SO.BRANCH SO.CEDAR WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 75.048,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 42.7m (140.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: E2289,  Location: 6.5 MI.N.NO.RICHFIELD INT (Lat: 38.853400,  Lng: -111.996733),  Route carried "on" structure: Interstate 70,  Year Built: 1988,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 9,548 (year 2020),  Truck Traffic: 38%,  Average Future Daily Traffic: 11,935 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SOUTH CEDAR WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 75.365,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 24 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 35.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: E229,  Location: 6.6 Mi. N. of Richfield (Lat: 38.854131,  Lng: -111.995342),  Route carried "on" structure: Interstate 70,  Year Built: 1988,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 9,548 (year 2020),  Truck Traffic: 38%,  Average Future Daily Traffic: 11,935 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STATE CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 75.510,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 24 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 37.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: E2291,  Location: 1 MILE SO.SIGURD INTCHG. (Lat: 38.866858,  Lng: -111.976450),  Route carried "on" structure: Interstate 70,  Year Built: 1988,  Status: Open,  Structure Length: 0.74m (2.43ft),  Average Daily Traffic: 9,548 (year 2020),  Truck Traffic: 38%,  Average Future Daily Traffic: 11,935 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORTH CEDAR WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 77.690,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 36.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: F 276,  Location: 8.2 MILES S. OF SALINA (Lat: 38.865214,  Lng: -111.965486),  Route carried "on" structure: State highway 24,  Year Built: 1927,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 1,499 (year 2020),  Truck Traffic: 20%,  Average Future Daily Traffic: 1,874 (year 2040),  Design Load: H 15,  Features Intersected: NORTH CEDAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.152,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.6m (31.5ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Testing,  Inventory Rating: 21.6 metric tons,  Method Used To Determine Inventory Rating: Load Testing,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: F 531,  Location: 1.1 MILE SO.SIGURD INTCH. (Lat: 38.860278,  Lng: -111.984444),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 8.67m (28.44ft),  Average Daily Traffic: 500 (year 2020),  Average Future Daily Traffic: 1,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-70 (SR-70) EBL & W,  Facility Carried by Structure: NO.CEDAR RIDGE RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 43.0m (141.1ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2F 486,  Location: SIGURD INTERCHANGE (Lat: 38.873653,  Lng: -111.965678),  Route carried "on" structure: Interstate 70,  Year Built: 1986,  Status: Open,  Structure Length: 3.61m (11.84ft),  Average Daily Traffic: 9,548 (year 2020),  Truck Traffic: 38%,  Average Future Daily Traffic: 11,935 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-259, INTCHG.X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 78.906,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.3m (40.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.4m (116.1ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2F 489,  Location: 1.2 MI.E.OF SIGURD INTCHG (Lat: 38.879606,  Lng: -111.944831),  Route carried "on" structure: Interstate 70,  Year Built: 1986,  Status: Open,  Structure Length: 6.79m (22.28ft),  Average Daily Traffic: 6,767 (year 2020),  Truck Traffic: 40%,  Average Future Daily Traffic: 8,459 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SEVIER RIVER & CO. R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 80.847,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2F 49,  Location: EAST OF SIGURD INTCHG. (Lat: 38.876119,  Lng: -111.958786),  Route carried "on" structure: Interstate 70,  Year Built: 1986,  Status: Open,  Structure Length: 11.76m (38.58ft),  Average Daily Traffic: 6,767 (year 2020),  Truck Traffic: 40%,  Average Future Daily Traffic: 8,459 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-24 & ABANDONED RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 79.563,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.8m (48.6ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 41.1m (134.8ft),  Curb-To-Curb Width: 14.8m (48.6ft),  Out-to-Out Width: 16.1m (52.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4F 486,  Location: SIGURD INTERCHANGE (Lat: 38.874053,  Lng: -111.965319),  Route carried "on" structure: Interstate 70,  Year Built: 1986,  Status: Open,  Structure Length: 3.61m (11.84ft),  Average Daily Traffic: 6,767 (year 2020),  Truck Traffic: 40%,  Average Future Daily Traffic: 8,459 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COUNTY RD.,INTCHG.X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 79.053,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.4m (116.1ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4F 489,  Location: 1.2 MI.E.OF SIGURD INTCHG (Lat: 38.879853,  Lng: -111.943889),  Route carried "on" structure: Interstate 70,  Year Built: 1986,  Status: Open,  Structure Length: 6.80m (22.31ft),  Average Daily Traffic: 6,767 (year 2020),  Truck Traffic: 40%,  Average Future Daily Traffic: 8,459 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SEVIER RIVER & CO. R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 81.041,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4F 49,  Location: EAST OF SIGURD INTCHG. (Lat: 38.876961,  Lng: -111.957231),  Route carried "on" structure: Interstate 70,  Year Built: 1986,  Status: Open,  Structure Length: 11.76m (38.58ft),  Average Daily Traffic: 6,767 (year 2020),  Truck Traffic: 40%,  Average Future Daily Traffic: 8,459 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-24 & ABANDONED RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 79.825,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 41.1m (134.8ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C 748,  Location: 5.8 MI.N.NO.RICHFIELD INT (Lat: 38.847714,  Lng: -112.007178),  Route carried "under" structure: Interstate 70,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 9,548 (year 2020),  Truck Traffic: 38%,  Features Intersected: I-70 (SR-70) EBL & WBL,  Facility Carried by Structure: SO.CEDAR RIDGE RD.
Minimum Vertical Clearance: 5.04m (16.54ft),  Kilometerpoint: 74.263,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.3m (165.0ft)

Find on map >>   Show street view

Structure Number: F 531,  Location: 1.1 MILE SO.SIGURD INTCH. (Lat: 38.860278,  Lng: -111.984444),  Route carried "under" structure: Interstate 70,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 9,548 (year 2020),  Truck Traffic: 38%,  Features Intersected: I-70 (SR-70) EBL & W,  Facility Carried by Structure: NO.CEDAR RIDGE RD.
Minimum Vertical Clearance: 5.07m (16.63ft),  Kilometerpoint: 76.669,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>   Show street view

Structure Number: 2F 486,  Location: SIGURD INTERCHANGE (Lat: 38.873653,  Lng: -111.965678),  Route carried "under" structure: State highway 259,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 3,686 (year 2020),  Truck Traffic: 30%,  Features Intersected: SR-259, INTCHG.X-ROAD,  Facility Carried by Structure: I-70 (SR-70) EBL
Minimum Vertical Clearance: 4.87m (15.98ft),  Kilometerpoint: 0.433,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 2F 489,  Location: 1.2 MI.E.OF SIGURD INTCHG (Lat: 38.879606,  Lng: -111.944831),  Route carried "under" structure: County highway ,  Year Built: 1986,  Structure Length: 0. m,  Features Intersected: SEVIER RIVER & CO. R,  Facility Carried by Structure: I-70 (SR-70) EBL
Minimum Vertical Clearance: 4.96m (16.27ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.3m (115.8ft)

Find on map >>   Show street view

Structure Number: 2F 49,  Location: EAST OF SIGURD INTCHG. (Lat: 38.876119,  Lng: -111.958786),  Route carried "under" structure: State highway 24,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 4,365 (year 2020),  Truck Traffic: 14%,  Features Intersected: SR-24 & ABANDONED RR,  Facility Carried by Structure: I-70 (SR-70) EBL
Minimum Vertical Clearance: 7.41m (24.31ft),  Kilometerpoint: 11.716,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.1m (134.8ft)

Find on map >>   Show street view

Structure Number: 4F 486,  Location: SIGURD INTERCHANGE (Lat: 38.874053,  Lng: -111.965319),  Route carried "under" structure: County highway 259,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 3,686 (year 2020),  Truck Traffic: 30%,  Features Intersected: COUNTY RD.,INTCHG.X-ROAD,  Facility Carried by Structure: I-70 (SR-70) WBL
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 4F 489,  Location: 1.2 MI.E.OF SIGURD INTCHG (Lat: 38.879853,  Lng: -111.943889),  Route carried "under" structure: County highway ,  Year Built: 1986,  Structure Length: 0. m,  Features Intersected: SEVIER RIVER & CO. R,  Facility Carried by Structure: I-70 (SR-70) WBL
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.3m (115.8ft)

Find on map >>   Show street view

Structure Number: 4F 49,  Location: EAST OF SIGURD INTCHG. (Lat: 38.876961,  Lng: -111.957231),  Route carried "under" structure: State highway 24,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 4,365 (year 2020),  Truck Traffic: 14%,  Features Intersected: SR-24 & ABANDONED RR,  Facility Carried by Structure: I-70 (SR-70) WBL
Minimum Vertical Clearance: 7.65m (25.10ft),  Kilometerpoint: 11.768,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.1m (134.8ft)