Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for St. Paul, Indiana (IN)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 180ft / 54.9mTotal length
  • $591,000Total costs
  • 71,376Total average daily traffic
  • 7,722Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for St. Paul
  • No street view available for this location

New bridges in St. Paul, IN - historical statistics
  • New bridges - historical statistics
  • 21910-1919
  • 91960-1969
  • 31970-1979
  • 21990-1999
  • 22000-2009
Reconstructed bridges in St. Paul, IN - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 01980-1989
  • 21990-1999
  • 02000-2009
  • 12010-2019
  • 12020-2022
Average Bridge Daily Traffic in St. Paul, IN
Average Bridge Truck Traffic in St. Paul, IN
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.7%Very good
  • 61.5%Good
  • 15.4%Satisfactory
  • 15.4%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 7.7%Very good
  • 69.2%Good
  • 15.4%Satisfactory
  • 7.7%Imminent failure
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 61.5%Good
  • 15.4%Satisfactory
  • 15.4%Fair
  • 7.7%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Good
  • 58.3%Satisfactory
  • 16.7%Fair
Find on map >>   Show street view

Structure Number: 4498,  Location: 04.63 E SR 244 (Lat: 39.453250,  Lng: -85.629300),  Route carried "on" structure: Alternate County highway ,  Year Built: 1961,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 7.39m (24.25ft),  Average Daily Traffic: 3,220 (year 2016),  Truck Traffic: 31%,  Average Future Daily Traffic: 4,430 (year 2036),  Design Load: HS 20,  Features Intersected: I-74,  Facility Carried by Structure: COUNTY LINE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.0m (75.5ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4499,  Location: 05.78 E SR 244 (Lat: 39.445031,  Lng: -85.610489),  Route carried "on" structure: Interstate 74,  Year Built: 1961,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 10,341 (year 2004),  Truck Traffic: 10%,  Average Future Daily Traffic: 20,462 (year 2031),  Design Load: HS 20+Mod,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 199.977,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.2m (36.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 45,  Location: 05.78 E SR 244 (Lat: 39.445189,  Lng: -85.610211),  Route carried "on" structure: Interstate 74,  Year Built: 1961,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 10,341 (year 2004),  Truck Traffic: 10%,  Average Future Daily Traffic: 20,462 (year 2031),  Design Load: HS 20+Mod,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 199.977,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.2m (36.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4501,  Location: 06.68 W US 421 (Lat: 39.437631,  Lng: -85.593250),  Route carried "on" structure: County highway ,  Year Built: 1961,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 6.47m (21.23ft),  Average Daily Traffic: 490 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 590 (year 2040),  Design Load: HL 93,  Features Intersected: I-74,  Facility Carried by Structure: CR 700 N
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 79.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 61.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1600003,  Location: 00.50 N OF CR 550 N (Lat: 39.423911,  Lng: -85.592019),  Route carried "on" structure: County highway 271,  Year Built: 1999,  Status: Open,  Structure Length: 9.17m (30.09ft),  Average Daily Traffic: 1,570 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,460 (year 2037),  Design Load: HS 20,  Features Intersected: FLATROCK RIVER,  Facility Carried by Structure: CR 421N
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1600004,  Location: 00.70 NW OF CR 650 W (Lat: 39.443169,  Lng: -85.611817),  Route carried "on" structure: County highway 271,  Year Built: 1993,  Status: Open,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 1,140 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,790 (year 2037),  Design Load: HS 20,  Features Intersected: MILL CREEK,  Facility Carried by Structure: CR 421N
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 56.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1600011,  Location: 01.20 SW OF CR 650 W (Lat: 39.430961,  Lng: -85.620911),  Route carried "on" structure: County highway 222,  Year Built: 2006,  Status: Open,  Structure Length: 1.59m (5.22ft),  Average Daily Traffic: 430 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 680 (year 2037),  Features Intersected: MILL CREEK,  Facility Carried by Structure: CR 650N
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 58.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 40.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1600012,  Location: 00.10 N OF CR 200 N (Lat: 39.366869,  Lng: -85.616250),  Route carried "on" structure: County highway 21,  Year Built: 1975,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 390 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 610 (year 2037),  Features Intersected: POND BRANCH,  Facility Carried by Structure: CR 700W
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 56.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1600018,  Location: 00.00 W OF CR 700 W (Lat: 39.364939,  Lng: -85.616939),  Route carried "on" structure: Alternate County highway 166,  Year Built: 2009,  Status: Open,  Structure Length: 1.74m (5.71ft),  Average Daily Traffic: 230 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 360 (year 2037),  Design Load: HS 20,  Features Intersected: POND BRANCH,  Facility Carried by Structure: CR 200N
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 160004,  Location: 00.10 W OF CR 225 E (Lat: 39.348800,  Lng: -85.447561),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 1,000 (year 2017),  Truck Traffic: 9%,  Average Future Daily Traffic: 1,570 (year 2037),  Features Intersected: SAND CREEK,  Facility Carried by Structure: NE 80
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.1m (26.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1600049,  Location: 00.50 N OF CR 550 N (Lat: 39.423469,  Lng: -85.625150),  Route carried "on" structure: City street 21,  Year Built: 1966,  Status: Open,  Structure Length: 8.44m (27.69ft),  Average Daily Traffic: 390 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 610 (year 2037),  Features Intersected: FLATROCK RIVER,  Facility Carried by Structure: CR 700W
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 22.7m (74.5ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 69.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 29.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1600157,  Location: 00.00 E OF CR 700 W (Lat: 39.368050,  Lng: -85.615539),  Route carried "on" structure: Alternate County highway 66,  Year Built: 1975,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 320 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 500 (year 2037),  Features Intersected: POND BRANCH,  Facility Carried by Structure: CR 240NW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 5.5m (18.0ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 1.71m (5.61ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $297,000,  Roadway Improvement Cost: $211,000,  Total Project Cost: $591,000 ( Estimate for 2021)
Find on map >>   Show street view

Structure Number: 7000182,  Location: 00.30 E OF CR 875 W (Lat: 39.460781,  Lng: -85.600900),  Route carried "on" structure: County highway 4,  Year Built: 1910,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 150 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 200 (year 2039),  Design Load: HS 20,  Features Intersected: MILL CREEK,  Facility Carried by Structure: CR 1050S
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.5m (37.7ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 6.3m (20.7ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 64.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7300135,  Location: 01.10 N OF CR 850 S (Lat: 39.419061,  Lng: -85.633200),  Route carried "on" structure: County highway ,  Year Built: 1915,  Status: Closed,  Structure Length: 5.17m (16.96ft),  Truck Traffic: 5%,  Average Future Daily Traffic: 700 (year 2039),  Features Intersected: FLATROCK RIVER,  Facility Carried by Structure: MOUND ROAD
Minimum Vertical Clearance: 5.01m (16.44ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 1,  Length of Maximum Span: 31.6m (103.7ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Fair,  Superstructure: Imminent failure,  Substructure: Poor,  Channel: Satisfactory,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Open Grating,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 4498,  Location: 04.63 E SR 244 (Lat: 39.453250,  Lng: -85.629342),  Route carried "under" structure: Interstate 74,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 10,341 (year 2004),  Truck Traffic: 10%,  Features Intersected: I-74 EB,  Facility Carried by Structure: COUNTY LINE RD
Minimum Vertical Clearance: 5.37m (17.62ft),  Kilometerpoint: 198.126,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.0m (75.5ft)

Find on map >>   Show street view

Structure Number: 4498,  Location: 04.63 E SR 244 (Lat: 39.453250,  Lng: -85.629342),  Route carried "under" structure: Interstate 74,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 10,341 (year 2004),  Truck Traffic: 10%,  Features Intersected: I-74 WB,  Facility Carried by Structure: COUNTY LINE RD
Minimum Vertical Clearance: 5.37m (17.62ft),  Kilometerpoint: 198.126,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.0m (75.5ft)

Find on map >>   Show street view

Structure Number: 4501,  Location: 06.68 W US 421 (Lat: 39.437631,  Lng: -85.593247),  Route carried "under" structure: Interstate 74,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 10,341 (year 2004),  Truck Traffic: 10%,  Features Intersected: I-74 EB,  Facility Carried by Structure: CR 700 NORTH
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 201.667,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 4501,  Location: 06.68 W US 421 (Lat: 39.437631,  Lng: -85.593247),  Route carried "under" structure: Interstate 74,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 10,341 (year 2004),  Truck Traffic: 10%,  Features Intersected: I-74 WB,  Facility Carried by Structure: CR 700 NORTH
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 201.667,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Discuss St. Paul, Indiana (IN) on our hugely popular Indiana forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.