Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Staley, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 112ft / 33.9mTotal length
  • 49,010Total average daily traffic
  • 6,118Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Staley
  • No street view available for this location

New bridges in Staley, NC - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 11950-1959
  • 21970-1979
  • 91980-1989
  • 41990-1999
  • 12010-2019
Average Bridge Daily Traffic in Staley, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 16.7%Very good
  • 50.0%Good
  • 16.7%Satisfactory
  • 16.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 33.3%Very good
  • 33.3%Good
  • 16.7%Fair
  • 16.7%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 83.3%Good
  • 16.7%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 55.6%Good
  • 44.4%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Good
  • 50.0%Satisfactory
  • 16.7%Fair
Find on map >>   Show street view

Structure Number: 370284,  Location: 0.2 MI. S. JCT. SR1346 (Lat: 35.822644,  Lng: -79.512572),  Route carried "on" structure: State highway 1300,  Year Built: 1951,  Status: Posted for load,  Structure Length: 2.28m (7.48ft),  Average Daily Traffic: 740 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,480 (year 2040),  Design Load: H 15,  Features Intersected: NORTH ROCKY RIVER PRONG
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.9m (35.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 30.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 370287,  Location: 0.2 MI. N. JCT. SR1306 (Lat: 35.814789,  Lng: -79.538869),  Route carried "on" structure: State highway 1305,  Year Built: 2015,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 110 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 220 (year 2040),  Design Load: HL 93,  Features Intersected: ROCKY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.1m (16.7ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.7m (31.8ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 37029,  Location: 0.2 MI. W. JCT. SR1377 (Lat: 35.797303,  Lng: -79.524808),  Route carried "on" structure: State highway 1308,  Year Built: 1998,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 120 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 240 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CR. OFF ROCKY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 370306,  Location: 1.0 MI. S. JCT. SR1301 (Lat: 35.827469,  Lng: -79.528633),  Route carried "on" structure: State highway 1303,  Year Built: 1971,  Status: Posted for load,  Structure Length: 2.77m (9.09ft),  Average Daily Traffic: 150 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 300 (year 2040),  Design Load: H 10,  Features Intersected: NORTH PRONG OF ROCKY RVR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Poor,  Channel: Good,  Operating Rating: 37.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 370455,  Location: 0.1 MI. S. JCT. SR1305 (Lat: 35.802944,  Lng: -79.540253),  Route carried "on" structure: State highway 1300,  Year Built: 1987,  Status: Open,  Structure Length: 6.24m (20.47ft),  Average Daily Traffic: 550 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,100 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US421
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 62.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 370456,  Location: 1.0 MI. W. JCT. SR1377 (Lat: 35.797675,  Lng: -79.534758),  Route carried "on" structure: State highway 1308,  Year Built: 1987,  Status: Open,  Structure Length: 6.52m (21.39ft),  Average Daily Traffic: 310 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 620 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US421
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.0m (105.0ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 63.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 370464,  Location: 0.3 MI. S. JCT. SR1307 (Lat: 35.807083,  Lng: -79.527603),  Route carried "on" structure: State highway 1300,  Year Built: 1970,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 550 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,100 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ROCKY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 1510133,  Location: 0.3 MI. S. JCT. SR2469 (Lat: 35.768744,  Lng: -79.557661),  Route carried "on" structure: State highway 2474,  Year Built: 1993,  Status: Open,  Structure Length: 2.49m (8.17ft),  Average Daily Traffic: 320 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 640 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BUSH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.1m (39.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1510202,  Location: 80 FT. MI.W. JCT. SR2475 (Lat: 35.743317,  Lng: -79.549889),  Route carried "on" structure: US 64,  Year Built: 1939,  Status: Open,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 8,400 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 16,800 (year 2040),  Design Load: HS 20,  Features Intersected: BUSH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 18.5m (60.7ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.3m (10.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 1510364,  Location: 0.5 MI. N. JCT. US64 (Lat: 35.750475,  Lng: -79.546647),  Route carried "on" structure: State highway 2475,  Year Built: 1995,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 120 (year 2000),  Truck Traffic: 6%,  Average Future Daily Traffic: 240 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 1510417,  Location: 1.0 MI.N.JCT.US64 (Lat: 35.756847,  Lng: -79.557433),  Route carried "on" structure: State highway 2474,  Year Built: 1992,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 340 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 680 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BRANCH OF BRUSH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 1510471,  Location: 1.2 MI. S. JCT. NC49 (Lat: 35.813900,  Lng: -79.554353),  Route carried "on" structure: US 421,  Year Built: 1987,  Status: Open,  Structure Length: 7.65m (25.10ft),  Average Daily Traffic: 6,500 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 16,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1006
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.834,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 21),  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 14 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 44.5m (146.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 84.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 370455,  Location: 0.1 MI. S. JCT. SR1305 (Lat: 35.802944,  Lng: -79.540253),  Route carried "under" structure: US 421,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: SR1300
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.3m (106.0ft)

Find on map >>   Show street view

Structure Number: 370455,  Location: 0.1 MI. S. JCT. SR1305 (Lat: 35.802944,  Lng: -79.540253),  Route carried "under" structure: US 421,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: SR1300
Minimum Vertical Clearance: 5.96m (19.55ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.3m (106.0ft)

Find on map >>   Show street view

Structure Number: 370456,  Location: 1.0 MI. W. JCT. SR1377 (Lat: 35.797675,  Lng: -79.534758),  Route carried "under" structure: US 421,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1308
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 54.346,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Find on map >>   Show street view

Structure Number: 370456,  Location: 1.0 MI. W. JCT. SR1377 (Lat: 35.797675,  Lng: -79.534758),  Route carried "under" structure: US 421,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1308
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 54.346,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Find on map >>   Show street view

Structure Number: 151047,  Location: 1.2 MI. S. JCT. NC49 (Lat: 35.813564,  Lng: -79.554206),  Route carried "under" structure: State highway 1006,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 3,400 (year 2019),  Truck Traffic: 7%,  Features Intersected: US421S
Minimum Vertical Clearance: 5.24m (17.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.1m (144.7ft)

Find on map >>   Show street view

Structure Number: 1510471,  Location: 1.2 MI. S. JCT. NC49 (Lat: 35.813900,  Lng: -79.554353),  Route carried "under" structure: State highway 1006,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 3,400 (year 2019),  Truck Traffic: 7%,  Features Intersected: US421N
Minimum Vertical Clearance: 5.86m (19.23ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.5m (146.0ft)