Bridge Statistics for Summit Park, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 12Number of bridges
  • 82ft / 24.9mTotal length
  • 323,336Total average daily traffic
  • 80,077Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Summit Park
  • No street view available for this location

New bridges in Summit Park, UT - historical statistics
  • New bridges - historical statistics
  • 81970-1979
  • 42010-2019
Average Bridge Daily Traffic in Summit Park, UT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 33.3%Good
  • 33.3%Satisfactory
  • 33.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 16.7%Very good
  • 16.7%Good
  • 33.3%Satisfactory
  • 33.3%Fair
Find on map >>   Show street view

Structure Number: 2C1004,  Location: At Parleys Summit Intchg (Lat: 40.752781,  Lng: -111.614897),  Route carried "on" structure: Interstate 80,  Year Built: 2011,  Status: Open,  Structure Length: 4.04m (13.25ft),  Average Daily Traffic: 55,066 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 68,833 (year 2040),  Design Load: HL 93,  Features Intersected: INT.X-RD@PARLEYS SUMMIT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 224.772,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.3m (73.2ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.6m (129.9ft),  Curb-To-Curb Width: 22.3m (73.2ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2F 86,  Location: JEREMY RANCH INTCHG. (Lat: 40.753956,  Lng: -111.573011),  Route carried "on" structure: Interstate 80,  Year Built: 1971,  Status: Open,  Structure Length: 5.77m (18.93ft),  Average Daily Traffic: 55,066 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 68,833 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CO. RD. INTCHG. X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 228.588,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 17.2m (56.4ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 2F 254R,  Location: At Lambs Canyon Intchg. (Lat: 40.739278,  Lng: -111.672886),  Route carried "on" structure: Interstate 80,  Year Built: 1972,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 51,742 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 64,678 (year 2040),  Design Load: HL 93,  Features Intersected: LAMBS CYN.RD.,INT.X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 219.483,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 16.4m (53.8ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 39.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4C1004,  Location: At Parleys Summit Intchg. (Lat: 40.752833,  Lng: -111.614158),  Route carried "on" structure: Interstate 80,  Year Built: 2011,  Status: Open,  Structure Length: 4.04m (13.25ft),  Average Daily Traffic: 51,639 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 64,549 (year 2040),  Design Load: HL 93,  Features Intersected: INT.X-RD@PARLEYS SUMMIT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 224.700,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.3m (73.2ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.6m (129.9ft),  Curb-To-Curb Width: 22.3m (73.2ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4F 86,  Location: JEREMY RANCH INTCHG. (Lat: 40.753542,  Lng: -111.571653),  Route carried "on" structure: Interstate 80,  Year Built: 1971,  Status: Open,  Structure Length: 5.77m (18.93ft),  Average Daily Traffic: 55,066 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 68,833 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CO.RD. INTCHG. X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 228.585,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.2m (56.4ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 17.2m (56.4ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 4F 254R,  Location: At the Lambs Canyon Int. (Lat: 40.739347,  Lng: -111.672342),  Route carried "on" structure: Interstate 80,  Year Built: 1972,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 2.56m (8.40ft),  Average Daily Traffic: 51,742 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 64,678 (year 2040),  Design Load: HL 93,  Features Intersected: LAMBS CYN.RD.,INT.X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 219.387,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 16.4m (53.8ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 26 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2C1004,  Location: At Parleys Summit Intchg (Lat: 40.752781,  Lng: -111.614897),  Route carried "under" structure: County highway ,  Year Built: 2011,  Structure Length: 0. m,  Features Intersected: INT.X-RD@PARLEYS SUMMIT,  Facility Carried by Structure: I-80EB, (SR-80)
Minimum Vertical Clearance: 6.97m (22.87ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 2F 86,  Location: JEREMY RANCH INTCHG. (Lat: 40.753956,  Lng: -111.573011),  Route carried "under" structure: County highway 2605,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 939 (year 2020),  Features Intersected: CO. RD. INTCHG. X-ROAD,  Facility Carried by Structure: I-80 (SR-80) EBL
Minimum Vertical Clearance: 4.99m (16.37ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 2F 254R,  Location: At Lambs Canyon Intchg. (Lat: 40.739278,  Lng: -111.672886),  Route carried "under" structure: County highway ,  Year Built: 1972,  Structure Length: 0. m,  Features Intersected: LAMBS CYN.RD.,INT.X-ROAD,  Facility Carried by Structure: I-80EB (SR-80)
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Find on map >>   Show street view

Structure Number: 4C1004,  Location: At Parleys Summit Intchg. (Lat: 40.752833,  Lng: -111.614158),  Route carried "under" structure: County highway 2602,  Year Built: 2011,  Structure Length: 0. m,  Average Daily Traffic: 1,137 (year 2020),  Features Intersected: INT.X-RD@PARLEYS SUMMIT,  Facility Carried by Structure: I-80WB, (SR-80)
Minimum Vertical Clearance: 5.22m (17.13ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 4F 86,  Location: JEREMY RANCH INTCHG. (Lat: 40.753542,  Lng: -111.571653),  Route carried "under" structure: County highway 2605,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 939 (year 2020),  Features Intersected: CO.RD. INTCHG. X-ROAD,  Facility Carried by Structure: I-80 (SR-80) WBL
Minimum Vertical Clearance: 6.97m (22.87ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 4F 254R,  Location: At the Lambs Canyon Int. (Lat: 40.739347,  Lng: -111.672342),  Route carried "under" structure: County highway ,  Year Built: 1972,  Structure Length: 0. m,  Features Intersected: LAMBS CYN.RD.,INT.X-ROAD,  Facility Carried by Structure: I-80WB (SR-80)
Minimum Vertical Clearance: 5.04m (16.54ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)