  • 12Number of bridges
  • 135ft / 40.5mTotal length
  • $3,592,000Total costs
  • 83,570Total average daily traffic
  • 7,957Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Taylor
  • No street view available for this location

New bridges in Taylor, PA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 21950-1959
  • 11980-1989
  • 41990-1999
  • 22000-2009
  • 22010-2019
Average Bridge Daily Traffic in Taylor, PA
Average Bridge Truck Traffic in Taylor, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 11.1%Very good
  • 55.6%Good
  • 11.1%Satisfactory
  • 22.2%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 11.1%Excellent
  • 22.2%Very good
  • 33.3%Good
  • 11.1%Satisfactory
  • 22.2%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.1%Very good
  • 55.6%Good
  • 22.2%Satisfactory
  • 11.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Satisfactory
  • 66.7%Fair
Find on map >>   Show street view

Structure Number: 20753,  Location: NEWTON TWP .6 M E SR 3001 (Lat: 41.444414,  Lng: -75.773083),  Route carried "on" structure: State highway ,  Year Built: 1958,  Status: Posted for load,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 244 (year 2022),  Truck Traffic: 10%,  Average Future Daily Traffic: 402 (year 2032),  Design Load: HS 20,  Features Intersected: GARDNER CREEK,  Facility Carried by Structure: SR 3006
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.792,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 24.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 10.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.20m (3.94ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: November 2019,  Other Special Inspection Date: November 2020,  Bridge Improvement Cost: $29,000,  Roadway Improvement Cost: $196,000,  Total Project Cost: $389,000 ( Estimate for 2030),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20756,  Location: RANSOM TWP 152' N SR 3002 (Lat: 41.423611,  Lng: -75.770278),  Route carried "on" structure: State highway ,  Year Built: 1988,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 191 (year 2022),  Truck Traffic: 14%,  Average Future Daily Traffic: 431 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: GARDNER CREEK,  Facility Carried by Structure: SR 3009
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.20m (3.94ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20764,  Location: TAYLOR BO 150' W SR 3010 (Lat: 41.394386,  Lng: -75.731250),  Route carried "on" structure: State highway ,  Year Built: 1957,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 9,285 (year 2022),  Truck Traffic: 10%,  Average Future Daily Traffic: 10,218 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: ST JOHNS CREEK,  Facility Carried by Structure: SR 3011
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.369,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 88.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.30m (4.27ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 20777,  Location: TAYLOR BOR 200' E SR 3013 (Lat: 41.383500,  Lng: -75.708439),  Route carried "on" structure: State highway ,  Year Built: 1990,  Status: Open,  Structure Length: 18.53m (60.79ft),  Average Daily Traffic: 16,196 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,571 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: RBMN RR & LACKA RIVER,  Facility Carried by Structure: SR 3016 DAVIS ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 40.5m (132.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 88.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 19.20m (62.99ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: July 2020,  Underwater Inspection Date: April 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 20947,  Location: TAYLOR BOROUGH (Lat: 41.396231,  Lng: -75.731031),  Route carried "on" structure: Interstate 476,  Year Built: 1995,  Status: Open,  Structure Length: 5.39m (17.68ft),  Average Daily Traffic: 6,895 (year 2001),  Truck Traffic: 19%,  Average Future Daily Traffic: 101,587 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: SR 3011, LR35049
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 3,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 26.8m (87.9ft),  Skew: 34 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 51.8m (169.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 25.9m (85.0ft),  Out-to-Out Width: 27.9m (91.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.60m (24.93ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $237,000,  Roadway Improvement Cost: $699,000,  Total Project Cost: $3,203,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 20948,  Location: KEYSER AVE. INTERCHANGE (Lat: 41.395000,  Lng: -75.723333),  Route carried "on" structure: Ramp Interstate 476,  Year Built: 1994,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 6,895 (year 2001),  Truck Traffic: 19%,  Average Future Daily Traffic: 16,997 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: ST. JOHN'S CREEK,  Facility Carried by Structure: PA TPK (RAMP B)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 6 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft)

Condition: Channel: Fair,  Culverts: Good,  Inventory Rating: 99.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019
Find on map >>   Show street view

Structure Number: 44285,  Location: TAYLOR BORO (Lat: 41.410383,  Lng: -75.720558),  Route carried "on" structure: State highway ,  Year Built: 2007,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 754 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,273 (year 2032),  Design Load: HL 93,  Features Intersected: PA TURNPIKE,  Facility Carried by Structure: S.R. 3002
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.818,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 93.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 48391,  Location: 225 FT S OAK ST INTERSCT (Lat: 41.390064,  Lng: -75.698311),  Route carried "on" structure: State highway ,  Year Built: 2013,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 13,981 (year 2022),  Truck Traffic: 6%,  Average Future Daily Traffic: 17,622 (year 2036),  Design Load: HL 93,  Features Intersected: CP RAIL/D&H RAILROAD,  Facility Carried by Structure: SR 3013 MAIN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.206,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.0m (68.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.7m (41.7ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Good,  Superstructure: Excellent,  Substructure: Good,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 54784,  Location: TAYLOR BO .7M N SR 3016 (Lat: 41.377806,  Lng: -75.720806),  Route carried "on" structure: State highway ,  Year Built: 2017,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 11,600 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 13,848 (year 2038),  Design Load: HL 93,  Features Intersected: PA TPK (Toll 476),  Facility Carried by Structure: SR 3013
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.401,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Toll Authority,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.0m (59.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 47.6 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 57681,  Location: 0.4 MILES S SR 3012 (Lat: 41.387583,  Lng: -75.704722),  Route carried "on" structure: City street ,  Year Built: 1910,  Status: Posted for load,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 100 (year 2020),  Average Future Daily Traffic: 100 (year 2040),  Features Intersected: KEYSER CREEK,  Facility Carried by Structure: OLD MAIN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Steel,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 14.8m (48.6ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Channel: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Length Of Structure Improvement: 0.80m (2.62ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: April 2020,  Other Special Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20947,  Location: TAYLOR BOROUGH (Lat: 41.396231,  Lng: -75.731031),  Route carried "under" structure: State highway ,  Year Built: 1995,  Structure Length: 0. m,  Average Daily Traffic: 9,285 (year 2022),  Truck Traffic: 10%,  Features Intersected: SR 3011, LR35049,  Facility Carried by Structure: PA TPK (I-476)
Minimum Vertical Clearance: 6.06m (19.88ft),  Kilometerpoint: 4.369,  Lanes on structure: 5,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 51.8m (169.9ft)

Find on map >>   Show street view

Structure Number: 44285,  Location: TAYLOR BORO (Lat: 41.410383,  Lng: -75.720558),  Route carried "under" structure: Interstate 476,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 8,144 (year 2007),  Truck Traffic: 17%,  Features Intersected: PA TURNPIKE,  Facility Carried by Structure: S.R. 3002
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 198.496,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)