Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Vander, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 33Number of bridges
  • 276ft / 84.0mTotal length
  • 353,053Total average daily traffic
  • 68,350Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Vander
  • No street view available for this location

New bridges in Vander, NC - historical statistics
  • New bridges - historical statistics
  • 321970-1979
  • 12010-2019
Average Bridge Daily Traffic in Vander, NC
Average Bridge Truck Traffic in Vander, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 11.1%Very good
  • 66.7%Good
  • 22.2%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 11.1%Very good
  • 77.8%Good
  • 11.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.1%Very good
  • 66.7%Good
  • 11.1%Satisfactory
  • 11.1%Fair
Find on map >>   Show street view

Structure Number: 510011,  Location: 0.2 MI.S. OF JCT.SR2000 (Lat: 35.021525,  Lng: -78.805206),  Route carried "on" structure: State highway 2008,  Year Built: 2011,  Status: Open,  Structure Length: 2.95m (9.68ft),  Average Daily Traffic: 1,700 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,400 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: LOCKS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 63.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 51011,  Location: 0.2 MI.W.JCT.SR2010 (Lat: 35.016544,  Lng: -78.787928),  Route carried "on" structure: State highway 2012,  Year Built: 1971,  Status: Posted for load,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 620 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,240 (year 2040),  Features Intersected: LOCKS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 20.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2021,  Underwater Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 510135,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042656,  Lng: -78.803261),  Route carried "on" structure: State highway 24,  Year Built: 1979,  Status: Open,  Structure Length: 12.77m (41.90ft),  Average Daily Traffic: 4,900 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 24),  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 52.7m (172.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 68.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 510136,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042911,  Lng: -78.803186),  Route carried "on" structure: State highway 24,  Year Built: 1979,  Status: Open,  Structure Length: 12.77m (41.90ft),  Average Daily Traffic: 13,375 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 26,750 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 24),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 2,  Length of Maximum Span: 52.7m (172.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 68.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 510137,  Location: 0.1 MI.N. JCT.SR1006 (Lat: 35.041492,  Lng: -78.773447),  Route carried "on" structure: State highway 1831,  Year Built: 1979,  Status: Open,  Structure Length: 6.98m (22.90ft),  Average Daily Traffic: 4,500 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 9,000 (year 2040),  Design Load: HS 15,  Features Intersected: NC24
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.1m (88.9ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 87.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 510138,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042486,  Lng: -78.803308),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1979,  Status: Open,  Structure Length: 12.77m (41.90ft),  Average Daily Traffic: 4,900 (year 2018),  Truck Traffic: 23%,  Average Future Daily Traffic: 9,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 52.7m (172.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 64.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 510139,  Location: 0.4 MI. W. JCT. SR1835 (Lat: 35.043086,  Lng: -78.803131),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1979,  Status: Open,  Structure Length: 12.77m (41.90ft),  Average Daily Traffic: 2,450 (year 2018),  Truck Traffic: 23%,  Average Future Daily Traffic: 4,900 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 2,  Length of Maximum Span: 52.7m (172.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 68.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 51014,  Location: 150' S.JCT SR1836 (Lat: 35.041808,  Lng: -78.795700),  Route carried "on" structure: State highway 1835,  Year Built: 1979,  Status: Open,  Structure Length: 10.54m (34.58ft),  Average Daily Traffic: 1,700 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 3,400 (year 2040),  Design Load: HS 15,  Features Intersected: NC24
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 45.4m (149.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 61.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 510146,  Location: 0.1 MI. E. OF JCT. SR1834 (Lat: 35.053200,  Lng: -78.798825),  Route carried "on" structure: State highway 1835,  Year Built: 1979,  Status: Open,  Structure Length: 11.36m (37.27ft),  Average Daily Traffic: 1,700 (year 2016),  Truck Traffic: 8%,  Average Future Daily Traffic: 3,400 (year 2040),  Design Load: HS 15,  Features Intersected: I95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 46.9m (153.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 510135,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042656,  Lng: -78.803261),  Route carried "under" structure: Ramp State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 3,266 (year 2018),  Truck Traffic: 14%,  Features Intersected: NC24E
Minimum Vertical Clearance: 5.42m (17.78ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510135,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042656,  Lng: -78.803261),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 26,750 (year 2018),  Truck Traffic: 16%,  Features Intersected: NC24E
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510135,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042656,  Lng: -78.803261),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 26,750 (year 2018),  Truck Traffic: 16%,  Features Intersected: NC24E
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510135,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042656,  Lng: -78.803261),  Route carried "under" structure: Ramp State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 3,266 (year 2018),  Truck Traffic: 14%,  Features Intersected: NC24E
Minimum Vertical Clearance: 5.27m (17.29ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510136,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042911,  Lng: -78.803186),  Route carried "under" structure: Ramp State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 4,900 (year 2018),  Truck Traffic: 14%,  Features Intersected: NC24 WBL
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510136,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042911,  Lng: -78.803186),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 14,125 (year 2018),  Truck Traffic: 23%,  Features Intersected: NC24 WBL
Minimum Vertical Clearance: 5.30m (17.39ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510136,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042911,  Lng: -78.803186),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 13,375 (year 2018),  Truck Traffic: 23%,  Features Intersected: NC24 WBL
Minimum Vertical Clearance: 5.27m (17.29ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510136,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042911,  Lng: -78.803186),  Route carried "under" structure: Ramp State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 4,900 (year 2018),  Truck Traffic: 14%,  Features Intersected: NC24 WBL
Minimum Vertical Clearance: 5.53m (18.14ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510137,  Location: 0.1 MI.N. JCT.SR1006 (Lat: 35.041492,  Lng: -78.773447),  Route carried "under" structure: State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1831
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 510137,  Location: 0.1 MI.N. JCT.SR1006 (Lat: 35.041492,  Lng: -78.773447),  Route carried "under" structure: State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1831
Minimum Vertical Clearance: 5.35m (17.55ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 510138,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042486,  Lng: -78.803308),  Route carried "under" structure: Ramp State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 19,000 (year 2013),  Truck Traffic: 16%,  Features Intersected: I95NRAMP,NC24E.CON
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510138,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042486,  Lng: -78.803308),  Route carried "under" structure: Ramp State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 26,750 (year 2018),  Truck Traffic: 23%,  Features Intersected: I95NRAMP,NC24E.CON
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510138,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042486,  Lng: -78.803308),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 26,750 (year 2018),  Truck Traffic: 23%,  Features Intersected: I95NRAMP,NC24E.CON
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510138,  Location: 0.4 MI.W.JCT.SR1835 (Lat: 35.042486,  Lng: -78.803308),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 26,750 (year 2018),  Truck Traffic: 23%,  Features Intersected: I95NRAMP,NC24E.CON
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510139,  Location: 0.4 MI. W. JCT. SR1835 (Lat: 35.043086,  Lng: -78.803131),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 13,375 (year 2018),  Truck Traffic: 23%,  Features Intersected: I95RAMP,NC24W.CON
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510139,  Location: 0.4 MI. W. JCT. SR1835 (Lat: 35.043086,  Lng: -78.803131),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 6,688 (year 2018),  Truck Traffic: 23%,  Features Intersected: I95RAMP,NC24W.CON
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510139,  Location: 0.4 MI. W. JCT. SR1835 (Lat: 35.043086,  Lng: -78.803131),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 13,375 (year 2018),  Truck Traffic: 23%,  Features Intersected: I95RAMP,NC24W.CON
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 510139,  Location: 0.4 MI. W. JCT. SR1835 (Lat: 35.043086,  Lng: -78.803131),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 6,688 (year 2018),  Truck Traffic: 23%,  Features Intersected: I95RAMP,NC24W.CON
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 15.727,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.7m (172.9ft)

Find on map >>   Show street view

Structure Number: 51014,  Location: 150' S.JCT SR1836 (Lat: 35.041808,  Lng: -78.795700),  Route carried "under" structure: State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1835
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.4m (149.0ft)

Find on map >>   Show street view

Structure Number: 51014,  Location: 150' S.JCT SR1836 (Lat: 35.041808,  Lng: -78.795700),  Route carried "under" structure: Ramp State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1835
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.4m (149.0ft)

Find on map >>   Show street view

Structure Number: 51014,  Location: 150' S.JCT SR1836 (Lat: 35.041808,  Lng: -78.795700),  Route carried "under" structure: Ramp State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2012),  Truck Traffic: 14%,  Features Intersected: SR1835
Minimum Vertical Clearance: 5.35m (17.55ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.4m (149.0ft)

Find on map >>   Show street view

Structure Number: 51014,  Location: 150' S.JCT SR1836 (Lat: 35.041808,  Lng: -78.795700),  Route carried "under" structure: State highway 24,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1835
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.4m (149.0ft)

Find on map >>   Show street view

Structure Number: 510146,  Location: 0.1 MI. E. OF JCT. SR1834 (Lat: 35.053200,  Lng: -78.798825),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 23,750 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1835
Minimum Vertical Clearance: 5.58m (18.31ft),  Kilometerpoint: 15.941,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.9m (153.9ft)

Find on map >>   Show street view

Structure Number: 510146,  Location: 0.1 MI. E. OF JCT. SR1834 (Lat: 35.053200,  Lng: -78.798825),  Route carried "under" structure: Interstate 95,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 23,750 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1835
Minimum Vertical Clearance: 5.63m (18.47ft),  Kilometerpoint: 1585.893,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.9m (153.9ft)

Discuss Vander, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.