  • National Bridge Inventory (NBI) Statistics
  • 20Number of bridges
  • 167ft / 51.3mTotal length
  • $1,306,000Total costs
  • 616,528Total average daily traffic
  • 33,910Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Village of Clarkston
  • No street view available for this location

New bridges in Village of Clarkston, MI - historical statistics
  • New bridges - historical statistics
  • 121960-1969
  • 11970-1979
  • 21990-1999
  • 52000-2009
Average Bridge Daily Traffic in Village of Clarkston, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 22.2%Good
  • 55.6%Satisfactory
  • 22.2%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 22.2%Very good
  • 44.4%Good
  • 33.3%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.1%Very good
  • 44.4%Good
  • 33.3%Satisfactory
  • 11.1%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 60.0%Good
  • 20.0%Satisfactory
  • 20.0%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Very good
  • 33.3%Satisfactory
  • 33.3%Poor
Find on map >>   Show street view

Structure Number: 8019,  Location: 2.2 MI SE OF M-15 (Lat: 42.736158,  Lng: -83.379631),  Route carried "on" structure: County highway 2059,  Year Built: 1962,  Status: Open,  Structure Length: 11.18m (36.68ft),  Average Daily Traffic: 13,460 (year 1987),  Truck Traffic: 3%,  Design Load: H 20,  Features Intersected: I-75,  Facility Carried by Structure: SASHABAW RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.487,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.8m (110.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 16.0m (52.5ft),  Out-to-Out Width: 19.7m (64.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $384,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 802,  Location: 1.1 MI SE OF M-15 (Lat: 42.745222,  Lng: -83.399769),  Route carried "on" structure: Interstate 75,  Year Built: 1962,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 35,763 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 55,750 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: CLARKSTON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 49.917,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.7m (41.7ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 78.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8021,  Location: 1.1 MI SE OF M-15 (Lat: 42.745681,  Lng: -83.399797),  Route carried "on" structure: Interstate 75,  Year Built: 1962,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 3.33m (10.93ft),  Average Daily Traffic: 35,763 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 48,200 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: CLARKSTON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 49.883,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.4m (40.7ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 78.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8022,  Location: @ M-15 (Lat: 42.746400,  Lng: -83.419517),  Route carried "on" structure: State highway 15,  Year Built: 2005,  Status: Open,  Structure Length: 6.00m (19.69ft),  Average Daily Traffic: 22,892 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 32,720 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: I-75
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.903,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 62,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.9m (98.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 4.4m (14.4ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 27.7m (90.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 95.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 803,  Location: 1.4 MI W OF M-15 (Lat: 42.742006,  Lng: -83.445869),  Route carried "on" structure: Interstate 75,  Year Built: 1962,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 56,522 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 71,851 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: DEERLAKE CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 53.812,  Lanes on structure: 6,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft),  Curb-To-Curb Width: 47.4m (155.5ft),  Out-to-Out Width: 96.3m (315.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 8031,  Location: 0.7 MI W OF M-15 (Lat: 42.746842,  Lng: -83.432558),  Route carried "on" structure: County highway 2059,  Year Built: 1962,  Status: Open,  Structure Length: 11.47m (37.63ft),  Average Daily Traffic: 1,680 (year 1974),  Average Future Daily Traffic: 1,680 (year 1977),  Design Load: H 15,  Features Intersected: I-75,  Facility Carried by Structure: HOLCOMB RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.686,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.1m (108.6ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 11.46m (37.60ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $1,106,000,  Roadway Improvement Cost: $97,000,  Total Project Cost: $1,145,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 8032,  Location: @ US-24 (Lat: 42.738961,  Lng: -83.451606),  Route carried "on" structure: US 24,  Year Built: 2004,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 26,557 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 39,813 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: I-75 SB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.552,  Lanes on structure: 5,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 68,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 26.6m (87.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 59.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8033,  Location: @ US-24 (Lat: 42.740514,  Lng: -83.453636),  Route carried "on" structure: Interstate 75,  Year Built: 1962,  Status: Open,  Structure Length: 6.00m (19.69ft),  Average Daily Traffic: 28,261 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 27,609 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: US-24
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 54.465,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.6m (107.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.01m (19.72ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 3 months,  Inspection Date: December 2020,  Other Special Inspection Date: January 2022,  Bridge Improvement Cost: $267,000,  Roadway Improvement Cost: $14,000,  Total Project Cost: $161,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 8185,  Location: BET AIRPORT AND CLEMENT R (Lat: 42.706656,  Lng: -83.427703),  Route carried "on" structure: County highway 2059,  Year Built: 1990,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 6,250 (year 2015),  Average Future Daily Traffic: 6,500 (year 2035),  Design Load: HS 20,  Features Intersected: CLINTON RIVER,  Facility Carried by Structure: ANDERSONVILLE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.410,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 70.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8186,  Location: BET AIRPORT AND CLEMENT R (Lat: 42.704308,  Lng: -83.419664),  Route carried "on" structure: County highway 2059,  Year Built: 1990,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 6,250 (year 2015),  Average Future Daily Traffic: 6,500 (year 2035),  Design Load: HS 20,  Features Intersected: CLINTON RIVER,  Facility Carried by Structure: ANDERSONVILLE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.120,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 70.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1325,  Location: INDEPENDENCE TWP SEC 20 (Lat: 42.744319,  Lng: -83.419442),  Route carried "on" structure: State highway 15,  Year Built: 2005,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 16,486 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 23,460 (year 2024),  Design Load: HS 25 or greater,  Features Intersected: CLINTON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.649,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: 62,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 26.5m (86.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 27.9m (91.5ft),  Out-to-Out Width: 34.1m (111.9ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 14031,  Location: 0.2 MI SE I-75&DIXIE HWY (Lat: 42.741389,  Lng: -83.445444),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Posted for load,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 200 (year 2017),  Average Future Daily Traffic: 328 (year 2042),  Design Load: HS 20,  Features Intersected: DEER LAKE CREEK,  Facility Carried by Structure: DEER HILL DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.808,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.2m (10.5ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 30.9m (101.4ft)

Condition: Channel: Poor,  Culverts: Poor,  Operating Rating: 21.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 12.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8018,  Location: 2.5 MI SE OF M-15 (Lat: 42.733786,  Lng: -83.375856),  Route carried "under" structure: Interstate 75,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 85,740 (year 2007),  Truck Traffic: 5%,  Features Intersected: I-75,  Facility Carried by Structure: WALDON RD
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 47.460,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.2m (118.8ft)

Find on map >>   Show street view

Structure Number: 8019,  Location: 2.2 MI SE OF M-15 (Lat: 42.736158,  Lng: -83.379631),  Route carried "under" structure: Interstate 75,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 85,740 (year 2007),  Truck Traffic: 5%,  Features Intersected: I-75,  Facility Carried by Structure: SASHABAW RD
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 47.865,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.8m (110.9ft)

Find on map >>   Show street view

Structure Number: 802,  Location: 1.1 MI SE OF M-15 (Lat: 42.745222,  Lng: -83.399769),  Route carried "under" structure: County highway 2059,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 3,740 (year 1974),  Features Intersected: CLARKSTON RD,  Facility Carried by Structure: I-75 SB
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 2.120,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.7m (41.7ft)

Find on map >>   Show street view

Structure Number: 8021,  Location: 1.1 MI SE OF M-15 (Lat: 42.745681,  Lng: -83.399797),  Route carried "under" structure: County highway 2059,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 3,740 (year 1974),  Features Intersected: CLARKSTON RD,  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 2.169,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.4m (40.7ft)

Find on map >>   Show street view

Structure Number: 8022,  Location: @ M-15 (Lat: 42.746400,  Lng: -83.419517),  Route carried "under" structure: Interstate 75,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 71,526 (year 2007),  Truck Traffic: 7%,  Features Intersected: I-75,  Facility Carried by Structure: M-15
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 51.502,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 29.9m (98.1ft)

Find on map >>   Show street view

Structure Number: 8031,  Location: 0.7 MI W OF M-15 (Lat: 42.746842,  Lng: -83.432558),  Route carried "under" structure: Interstate 75,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 61,140 (year 2013),  Truck Traffic: 6%,  Features Intersected: I-75,  Facility Carried by Structure: HOLCOMB RD
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 52.605,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.1m (108.6ft)

Find on map >>   Show street view

Structure Number: 8032,  Location: @ US-24 (Lat: 42.738961,  Lng: -83.451606),  Route carried "under" structure: Interstate 75,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 28,261 (year 2007),  Truck Traffic: 10%,  Features Intersected: I-75 SB,  Facility Carried by Structure: US-24
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 54.412,  Lanes on structure: 5,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 21.6m (70.9ft)

Find on map >>   Show street view

Structure Number: 8033,  Location: @ US-24 (Lat: 42.740514,  Lng: -83.453636),  Route carried "under" structure: US 24,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 26,557 (year 2007),  Truck Traffic: 4%,  Features Intersected: US-24,  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 0.312,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Discuss Village of Clarkston, Michigan (MI) on our hugely popular Michigan forum.