Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Warsaw, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 39Number of bridges
  • 282ft / 85.7mTotal length
  • 250,670Total average daily traffic
  • 51,685Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Warsaw
  • No street view available for this location

New bridges in Warsaw, NC - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 11950-1959
  • 11960-1969
  • 21970-1979
  • 281980-1989
  • 31990-1999
  • 22000-2009
  • 12010-2019
Average Bridge Daily Traffic in Warsaw, NC
Average Bridge Truck Traffic in Warsaw, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 17.6%Very good
  • 35.3%Good
  • 35.3%Satisfactory
  • 11.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 17.6%Very good
  • 58.8%Good
  • 17.6%Satisfactory
  • 5.9%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.9%Very good
  • 35.3%Good
  • 47.1%Satisfactory
  • 11.8%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 30.8%Good
  • 15.4%Satisfactory
  • 46.2%Fair
  • 7.7%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 14.3%Good
  • 28.6%Satisfactory
  • 14.3%Fair
  • 42.9%Poor
Find on map >>   Show street view

Structure Number: 610001,  Location: 0.3 MI.W. JCT. SR1900 (Lat: 34.995075,  Lng: -78.080272),  Route carried "on" structure: State highway 1901,  Year Built: 1982,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 750 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STEWARTS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021
Find on map >>   Show street view

Structure Number: 610002,  Location: 0.8 MI N JCT SR1107 (Lat: 34.963722,  Lng: -78.080361),  Route carried "on" structure: US 117,  Year Built: 1938,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 3,700 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,400 (year 2040),  Design Load: HS 20,  Features Intersected: STEWARTS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 610009,  Location: 0.3 MI. E. JCT. SR1174 (Lat: 34.940853,  Lng: -78.140275),  Route carried "on" structure: State highway 1192,  Year Built: 1976,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 590 (year 2016),  Average Future Daily Traffic: 1,180 (year 2040),  Design Load: HS 20,  Features Intersected: CARLTONS MILL RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.1m (16.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Poor,  Culverts: Poor,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 61001,  Location: 0.5 MI. W. JCT. SR1105 (Lat: 34.946692,  Lng: -78.127547),  Route carried "on" structure: State highway 1112,  Year Built: 1979,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 430 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 860 (year 2040),  Design Load: HS 20,  Features Intersected: BUCKHALL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Fair,  Culverts: Poor,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 610071,  Location: 0.6 MI. N. JCT. SR1341 (Lat: 35.014669,  Lng: -78.151956),  Route carried "on" structure: State highway 1108,  Year Built: 1991,  Status: Open,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 1,700 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TURKEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 610073,  Location: 0.3 MI.S. OF JCT.SR1342 (Lat: 35.022933,  Lng: -78.126194),  Route carried "on" structure: State highway 1340,  Year Built: 1993,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 660 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,320 (year 2040),  Design Load: HS 20,  Features Intersected: TURKEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Fair,  Culverts: Poor,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 610075,  Location: 0.4 MI N JCT SR1338 (Lat: 35.057289,  Lng: -78.131750),  Route carried "on" structure: State highway 1301,  Year Built: 1966,  Status: Posted for load,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 250 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 500 (year 2040),  Features Intersected: BEAR SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 1 degrees,  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.8m (15.7ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 21.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 14.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2021,  Underwater Inspection Date: May 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 610083,  Location: 0.9 MI E.JCT US117 (Lat: 35.060267,  Lng: -78.100072),  Route carried "on" structure: State highway 1301,  Year Built: 1950,  Year Reconstructed: 1969,  Status: Posted for load,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 800 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,600 (year 2040),  Features Intersected: BEAR SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 29.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 19.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 610309,  Location: 1.1 MI. N. JCT. SR1300 (Lat: 35.026769,  Lng: -78.011058),  Route carried "on" structure: State highway 1301,  Year Built: 2009,  Status: Open,  Structure Length: 3.29m (10.79ft),  Average Daily Traffic: 2,100 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NAHUNGA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 610328,  Location: 0.8 MI S JCT SR1113 (Lat: 34.952236,  Lng: -78.089319),  Route carried "on" structure: State highway 1106,  Year Built: 2002,  Status: Open,  Structure Length: 2.95m (9.68ft),  Average Daily Traffic: 650 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,300 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STEWARTS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 70.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: December 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 610408,  Location: 0.3 MI. S. JCT. SR1112 (Lat: 34.943167,  Lng: -78.117306),  Route carried "on" structure: State highway 1105,  Year Built: 2014,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 400 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 800 (year 2040),  Design Load: HL 93,  Features Intersected: STEWARTS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 610419,  Location: 0.8 MI. S. JCT. SR1300 (Lat: 35.022194,  Lng: -77.959333),  Route carried "on" structure: State highway 1381,  Year Built: 1992,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 230 (year 1998),  Truck Traffic: 6%,  Average Future Daily Traffic: 460 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BEAVERDAM BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 610435,  Location: 0.2 MI. W. JCT. NC24 (Lat: 34.997458,  Lng: -78.133256),  Route carried "on" structure: Interstate 40,  Year Built: 1987,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 11,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 23,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SEABOARD COASTLINE RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 110.979,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 14.7m (48.2ft),  Out-to-Out Width: 15.6m (51.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 610436,  Location: 0.2 MI. W. JCT. NC24 (Lat: 34.997411,  Lng: -78.134158),  Route carried "on" structure: Interstate 40,  Year Built: 1987,  Status: Open,  Structure Length: 4.32m (14.17ft),  Average Daily Traffic: 11,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 23,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SEABOARD COASTLINE RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 110.979,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 610437,  Location: 0.5 MI.E.SR1107 (Lat: 34.946608,  Lng: -78.073894),  Route carried "on" structure: Interstate 40,  Year Built: 1987,  Status: Open,  Structure Length: 9.02m (29.59ft),  Average Daily Traffic: 12,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 25,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SCL RR, US117
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 112.594,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 610438,  Location: 0.5 M.E.SR1107 (Lat: 34.946350,  Lng: -78.073811),  Route carried "on" structure: Interstate 40,  Year Built: 1987,  Status: Open,  Structure Length: 9.02m (29.59ft),  Average Daily Traffic: 12,750 (year 2018),  Truck Traffic: 23%,  Average Future Daily Traffic: 25,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SCL RR,US117
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 112.594,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 610439,  Location: 0.1 MI. S. JCT. SR1338 (Lat: 35.049708,  Lng: -78.154392),  Route carried "on" structure: State highway 1337,  Year Built: 1988,  Status: Open,  Structure Length: 6.06m (19.88ft),  Average Daily Traffic: 270 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 540 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.8m (61.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 610445,  Location: 0.2 MI.S.JCT.SR1106 (Lat: 34.948633,  Lng: -78.082881),  Route carried "on" structure: State highway 1107,  Year Built: 1988,  Status: Open,  Structure Length: 6.18m (20.28ft),  Average Daily Traffic: 680 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,360 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.8m (61.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 610446,  Location: 1.2 MI.W.US117 (Lat: 34.951783,  Lng: -78.089919),  Route carried "on" structure: Interstate 40,  Year Built: 1988,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 11,500 (year 2015),  Truck Traffic: 23%,  Average Future Daily Traffic: 23,000 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: STEWART'S CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 112.259,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 22.8m (74.8ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: Febuary 2021,  Underwater Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 610447,  Location: 0.2 MI.S. OF JCT.SR1106 (Lat: 34.958839,  Lng: -78.103097),  Route carried "on" structure: State highway 1113,  Year Built: 1988,  Status: Open,  Structure Length: 6.27m (20.57ft),  Average Daily Traffic: 260 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 520 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 610448,  Location: 1.4 MI. N. JCT. SR1113 (Lat: 34.970744,  Lng: -78.118669),  Route carried "on" structure: State highway 1105,  Year Built: 1988,  Status: Open,  Structure Length: 6.49m (21.29ft),  Average Daily Traffic: 300 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 610449,  Location: 1.3 MI.E.JCT.SR1341 (Lat: 34.993497,  Lng: -78.132436),  Route carried "on" structure: Interstate 40,  Year Built: 1988,  Status: Open,  Structure Length: 4.32m (14.17ft),  Average Daily Traffic: 11,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 23,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC24
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 111.100,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 61045,  Location: 1.3 MI. E. JCT. SR1341 (Lat: 34.993475,  Lng: -78.134086),  Route carried "on" structure: Interstate 40,  Year Built: 1988,  Status: Open,  Structure Length: 4.26m (13.98ft),  Average Daily Traffic: 11,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 23,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC24
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 111.100,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 610451,  Location: 0.3 MI. E. JCT. SR1108 (Lat: 35.007569,  Lng: -78.136842),  Route carried "on" structure: State highway 1341,  Year Built: 1988,  Status: Open,  Structure Length: 6.03m (19.78ft),  Average Daily Traffic: 1,400 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 111.375,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.8m (61.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 610437,  Location: 0.5 MI.E.SR1107 (Lat: 34.946608,  Lng: -78.073894),  Route carried "under" structure: US 117,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 4,200 (year 2019),  Truck Traffic: 7%,  Features Intersected: I40W, NC24
Minimum Vertical Clearance: 7.31m (23.98ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.8m (110.9ft)

Find on map >>   Show street view

Structure Number: 610437,  Location: 0.5 MI.E.SR1107 (Lat: 34.946608,  Lng: -78.073894),  Route carried "under" structure: US 117,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 4,200 (year 2019),  Truck Traffic: 7%,  Features Intersected: I40W, NC24
Minimum Vertical Clearance: 7.13m (23.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.8m (110.9ft)

Find on map >>   Show street view

Structure Number: 610438,  Location: 0.5 M.E.SR1107 (Lat: 34.946350,  Lng: -78.073811),  Route carried "under" structure: US 117,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 2,000 (year 2018),  Truck Traffic: 7%,  Features Intersected: I40 EB,NC24
Minimum Vertical Clearance: 7.06m (23.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.8m (110.9ft)

Find on map >>   Show street view

Structure Number: 610439,  Location: 0.1 MI. S. JCT. SR1338 (Lat: 35.049708,  Lng: -78.154392),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 11,750 (year 2018),  Truck Traffic: 23%,  Features Intersected: SR1337
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 109.836,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Find on map >>   Show street view

Structure Number: 610439,  Location: 0.1 MI. S. JCT. SR1338 (Lat: 35.049708,  Lng: -78.154392),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 11,750 (year 2018),  Truck Traffic: 23%,  Features Intersected: SR1337
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 109.836,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Find on map >>   Show street view

Structure Number: 610445,  Location: 0.2 MI.S.JCT.SR1106 (Lat: 34.948633,  Lng: -78.082881),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 11,500 (year 2015),  Truck Traffic: 23%,  Features Intersected: SR1107
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 112.503,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Find on map >>   Show street view

Structure Number: 610445,  Location: 0.2 MI.S.JCT.SR1106 (Lat: 34.948633,  Lng: -78.082881),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 11,500 (year 2015),  Truck Traffic: 23%,  Features Intersected: SR1107
Minimum Vertical Clearance: 5.71m (18.73ft),  Kilometerpoint: 112.503,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Find on map >>   Show street view

Structure Number: 610447,  Location: 0.2 MI.S. OF JCT.SR1106 (Lat: 34.958839,  Lng: -78.103097),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1113
Minimum Vertical Clearance: 5.76m (18.90ft),  Kilometerpoint: 111.862,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 610447,  Location: 0.2 MI.S. OF JCT.SR1106 (Lat: 34.958839,  Lng: -78.103097),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1113
Minimum Vertical Clearance: 5.27m (17.29ft),  Kilometerpoint: 112.411,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 610448,  Location: 1.4 MI. N. JCT. SR1113 (Lat: 34.970744,  Lng: -78.118669),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1105
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 111.558,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.4m (66.9ft)

Find on map >>   Show street view

Structure Number: 610448,  Location: 1.4 MI. N. JCT. SR1113 (Lat: 34.970744,  Lng: -78.118669),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1105
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 111.558,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.4m (66.9ft)

Find on map >>   Show street view

Structure Number: 610449,  Location: 1.3 MI.E.JCT.SR1341 (Lat: 34.993497,  Lng: -78.132436),  Route carried "under" structure: State highway 24,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 7,100 (year 2019),  Truck Traffic: 14%,  Features Intersected: I40W
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.6m (70.9ft)

Find on map >>   Show street view

Structure Number: 61045,  Location: 1.3 MI. E. JCT. SR1341 (Lat: 34.993475,  Lng: -78.134086),  Route carried "under" structure: State highway 24,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 12,000 (year 2019),  Truck Traffic: 14%,  Features Intersected: I40 EBL
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 610451,  Location: 0.3 MI. E. JCT. SR1108 (Lat: 35.007569,  Lng: -78.136842),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 11,750 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1341
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 110.765,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Find on map >>   Show street view

Structure Number: 610451,  Location: 0.3 MI. E. JCT. SR1108 (Lat: 35.007569,  Lng: -78.136842),  Route carried "under" structure: Interstate 40,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 11,750 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1341
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 110.765,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Discuss Warsaw, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.