Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for West Frankfort, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 38Number of bridges
  • 394ft / 120mTotal length
  • $1,062,000Total costs
  • 335,000Total average daily traffic
  • 120,422Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for West Frankfort
  • No street view available for this location

New bridges in West Frankfort, IL - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 21950-1959
  • 131960-1969
  • 11970-1979
  • 21980-1989
  • 81990-1999
  • 42000-2009
  • 62010-2019
  • 12020-2022
Reconstructed bridges in West Frankfort, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 51980-1989
  • 21990-1999
Average Bridge Daily Traffic in West Frankfort, IL
Average Bridge Truck Traffic in West Frankfort, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.8%Excellent
  • 30.8%Very good
  • 26.9%Good
  • 30.8%Satisfactory
  • 7.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 3.8%Excellent
  • 38.5%Very good
  • 23.1%Good
  • 23.1%Satisfactory
  • 11.5%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 3.8%Excellent
  • 50.0%Very good
  • 34.6%Good
  • 7.7%Satisfactory
  • 3.8%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 8.0%Excellent
  • 60.0%Very good
  • 20.0%Good
  • 12.0%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 40.0%Very good
  • 20.0%Good
  • 40.0%Satisfactory
Find on map >>   Show street view

Structure Number: 280001,  Location: S OF SCL W FRANKFORT (Lat: 37.882642,  Lng: -88.942572),  Route carried "on" structure: Interstate 57,  Year Built: 1961,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 4.03m (13.22ft),  Average Daily Traffic: 15,500 (year 2020),  Truck Traffic: 44%,  Average Future Daily Traffic: 18,956 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: POND CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 102.255,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.4m (47.2ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: October 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 280002,  Location: S OF SCL W FRANKFORT (Lat: 37.882778,  Lng: -88.942619),  Route carried "on" structure: Interstate 57,  Year Built: 1961,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 4.03m (13.22ft),  Average Daily Traffic: 15,500 (year 2020),  Truck Traffic: 44%,  Average Future Daily Traffic: 18,956 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: POND CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 102.271,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.4m (47.2ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 81.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: October 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 280006,  Location: 1.5 MI N W FRANKFORT (Lat: 37.928444,  Lng: -88.946575),  Route carried "on" structure: Interstate 57,  Year Built: 1962,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 11.20m (36.75ft),  Average Daily Traffic: 20,000 (year 2021),  Truck Traffic: 39%,  Average Future Daily Traffic: 16,203 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: M. FORK BIG MUDDY R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 107.340,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 280007,  Location: 1.5 MI N W FRANKFORT (Lat: 37.928589,  Lng: -88.946572),  Route carried "on" structure: Interstate 57,  Year Built: 1962,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 11.20m (36.75ft),  Average Daily Traffic: 20,000 (year 2021),  Truck Traffic: 39%,  Average Future Daily Traffic: 16,203 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: M. FORK BIG MUDDY R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 107.356,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 280034,  Location: 0.5 MI N W FRANKFORT (Lat: 37.916650,  Lng: -88.933150),  Route carried "on" structure: State highway 37,  Year Built: 1938,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 11.20m (36.75ft),  Average Daily Traffic: 5,450 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,083 (year 2032),  Design Load: HS 20,  Features Intersected: M FORK BIG MUDDY R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 108.129,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 22.8m (74.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 60.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 12.19m (39.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $350,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $400,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 280039,  Location: IN WEST FRANKFORT (Lat: 37.897739,  Lng: -88.946175),  Route carried "on" structure: State highway 149,  Year Built: 1963,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 6.41m (21.03ft),  Average Daily Traffic: 10,400 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 15,356 (year 2032),  Design Load: HS 20,  Features Intersected: INTERSTATE 57
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.146,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.1m (79.1ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 21.5m (70.5ft),  Out-to-Out Width: 24.3m (79.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 57.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 280058,  Location: 1.5 MI S OF FAP 873 (Lat: 37.875811,  Lng: -88.941792),  Route carried "on" structure: Other road ,  Year Built: 1961,  Status: Open,  Structure Length: 7.31m (23.98ft),  Average Daily Traffic: 1,000 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 847 (year 2032),  Design Load: HS 15,  Features Intersected: FAI RTE 57,  Facility Carried by Structure: FAU 9496
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.173,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.0m (75.5ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 36.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 23.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: August 2020,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 280061,  Location: NEAR SCL W FRANKFORT (Lat: 37.891619,  Lng: -88.945100),  Route carried "on" structure: Other road ,  Year Built: 1962,  Status: Open,  Structure Length: 6.21m (20.37ft),  Average Daily Traffic: 600 (year 2019),  Truck Traffic: 11%,  Average Future Daily Traffic: 794 (year 2032),  Design Load: HS 15,  Features Intersected: INTERSTATE 57,  Facility Carried by Structure: NORTH RD-W FRANKFO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.933,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.4m (63.6ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Very good,  Operating Rating: 47.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 280062,  Location: 3.5 MI S BENTON (Lat: 37.950261,  Lng: -88.935792),  Route carried "on" structure: County highway ,  Year Built: 1962,  Status: Open,  Structure Length: 6.36m (20.87ft),  Average Daily Traffic: 1,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,059 (year 2032),  Design Load: HS 15,  Features Intersected: FAI 57,  Facility Carried by Structure: FAS 1877 (YELLOW B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.675,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.4m (60.4ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 280078,  Location: S OF SCL W FRANKFORT (Lat: 37.885156,  Lng: -88.931711),  Route carried "on" structure: State highway 37,  Year Built: 2012,  Status: Open,  Structure Length: 4.89m (16.04ft),  Average Daily Traffic: 7,500 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 8,100 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: POND CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 104.637,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 68.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 280079,  Location: AT NCL W. FRANKFORT (Lat: 37.908150,  Lng: -88.946419),  Route carried "on" structure: Interstate 57,  Year Built: 2012,  Status: Open,  Structure Length: 5.62m (18.44ft),  Average Daily Traffic: 20,000 (year 2021),  Truck Traffic: 39%,  Average Future Daily Traffic: 15,779 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: 7TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 105.071,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.1m (59.4ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.7m (90.9ft),  Curb-To-Curb Width: 18.1m (59.4ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 75.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 28008,  Location: AT NCL W. FRANKFORT (Lat: 37.908294,  Lng: -88.946419),  Route carried "on" structure: Interstate 57,  Year Built: 2012,  Status: Open,  Structure Length: 5.62m (18.44ft),  Average Daily Traffic: 20,000 (year 2021),  Truck Traffic: 39%,  Average Future Daily Traffic: 52,500 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: 7TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 105.087,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.1m (59.4ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.7m (90.9ft),  Curb-To-Curb Width: 18.1m (59.4ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 75.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 28201,  Location: 0.5 MI N W FRANKFORT (Lat: 37.921247,  Lng: -88.933131),  Route carried "on" structure: State highway 37,  Year Built: 1998,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 5,450 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,401 (year 2032),  Design Load: HS 20,  Features Intersected: BRANCH-MF BIG MUDDY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 108.628,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 62.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 282017,  Location: SCL WEST FRANKFORT (Lat: 37.888047,  Lng: -88.931711),  Route carried "on" structure: State highway 37,  Year Built: 2012,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 7,500 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 6,142 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM S W.FRANKFORT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 104.959,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2019
Find on map >>   Show street view

Structure Number: 283011,  Location: NEAR NE CL OF WF (Lat: 37.910572,  Lng: -88.896700),  Route carried "on" structure: County highway ,  Year Built: 1953,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 6.38m (20.93ft),  Average Daily Traffic: 1,500 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,012 (year 2032),  Design Load: HS 20,  Features Intersected: EWING CREEK,  Facility Carried by Structure: FAS 1872-DEERING R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.483,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.65m (25.10ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $441,000,  Roadway Improvement Cost: $44,000,  Total Project Cost: $662,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 283212,  Location: 1 MI S W. FRANKFORT (Lat: 37.879650,  Lng: -88.903014),  Route carried "on" structure: County highway ,  Year Built: 1979,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 900 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,112 (year 2032),  Design Load: HS 20,  Features Intersected: POND CREEK,  Facility Carried by Structure: TR 222
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.772,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 283228,  Location: NO 9 BLACKTOP (Lat: 37.895464,  Lng: -88.883708),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 1.30m (4.27ft),  Average Daily Traffic: 800 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,218 (year 2032),  Design Load: HS 20,  Features Intersected: TR EWING CREEK,  Facility Carried by Structure: CH 10
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.062,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.3m (14.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 283278,  Location: 1/2 MI S W FRANKFORT (Lat: 37.886417,  Lng: -88.921289),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 400 (year 2019),  Truck Traffic: 21%,  Average Future Daily Traffic: 530 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB POND CREEK,  Facility Carried by Structure: TR 204
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.193,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 283294,  Location: 1240E-140N (Lat: 37.883097,  Lng: -88.920950),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 2.36m (7.74ft),  Average Daily Traffic: 400 (year 2019),  Truck Traffic: 21%,  Average Future Daily Traffic: 530 (year 2032),  Design Load: HS 20,  Features Intersected: POND CREEK,  Facility Carried by Structure: TR 204
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.563,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.3m (76.4ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 283309,  Location: 000N 2000E (Lat: 37.864369,  Lng: -88.853978),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 1.73m (5.68ft),  Average Daily Traffic: 125 (year 2019),  Truck Traffic: 17%,  Average Future Daily Traffic: 79 (year 2032),  Design Load: HS 20,  Features Intersected: BRANCH POND CREEK,  Facility Carried by Structure: TR 260
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.527,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.3m (27.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 283322,  Location: 1225E025N (Lat: 37.865978,  Lng: -88.923300),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.26m (4.13ft),  Average Daily Traffic: 300 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 424 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB TO POND CREEK,  Facility Carried by Structure: TR 204
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.511,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 283329,  Location: 100N 1100E (Lat: 37.875217,  Lng: -88.946614),  Route carried "on" structure: Other road ,  Year Built: 1995,  Status: Open,  Structure Length: 4.88m (16.01ft),  Average Daily Traffic: 1,000 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 847 (year 2032),  Design Load: HS 20,  Features Intersected: POND CREEK,  Facility Carried by Structure: TR 403
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.738,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 283349,  Location: DEERING (Lat: 37.918206,  Lng: -88.876675),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 1.57m (5.15ft),  Average Daily Traffic: 50 (year 2019),  Truck Traffic: 26%,  Average Future Daily Traffic: 53 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB TO EWING CREEK,  Facility Carried by Structure: TR 327-MOORE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.336,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 283366,  Location: 0.7 M S WEST FRKFORT (Lat: 37.880508,  Lng: -88.902883),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 900 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,112 (year 2032),  Design Load: HS 20,  Features Intersected: POND CREEK,  Facility Carried by Structure: TR 222-S MARION RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.676,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 283381,  Location: OLD MARION RD (Lat: 37.881083,  Lng: -88.902789),  Route carried "on" structure: County highway ,  Year Built: 2004,  Status: Open,  Structure Length: 1.27m (4.17ft),  Average Daily Traffic: 900 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,112 (year 2032),  Design Load: HS 20,  Features Intersected: POND CREEK TRIB,  Facility Carried by Structure: TR 222
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.612,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 283382,  Location: RUSSELL ROAD (Lat: 37.891589,  Lng: -88.949081),  Route carried "on" structure: County highway ,  Year Built: 2004,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Future Daily Traffic: 344 (year 2032),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: TR 369
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.899,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.8m (9.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 28342,  Location: 0.5MI W OLD MARION R (Lat: 37.862314,  Lng: -88.914028),  Route carried "on" structure: County highway ,  Year Built: 2020,  Status: Open,  Structure Length: 1.42m (4.66ft),  Average Daily Traffic: 600 (year 2021),  Truck Traffic: 18%,  Average Future Daily Traffic: 630 (year 2037),  Design Load: HS 25 or greater,  Features Intersected: TRIB TO POND CREEK,  Facility Carried by Structure: HARMONY CHURCH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.478,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Excellent,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 285002,  Location: DEERING RD (Lat: 37.906917,  Lng: -88.899631),  Route carried "on" structure: Other road ,  Year Built: 1954,  Year Reconstructed: 1967,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,600 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,906 (year 2032),  Features Intersected: EWING CR,  Facility Carried by Structure: FAU 9489 WATER PL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1003146,  Location: 5 MI N OF PITTSBURG (Lat: 37.862517,  Lng: -88.854467),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 3.71m (12.17ft),  Average Daily Traffic: 125 (year 2021),  Truck Traffic: 17%,  Average Future Daily Traffic: 143 (year 2032),  Design Load: HS 20,  Features Intersected: POND CREEK,  Facility Carried by Structure: TR 552
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.064,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1003158,  Location: 3 MI NE JOHNSTON CTY (Lat: 37.862517,  Lng: -88.891706),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 1.27m (4.17ft),  Average Daily Traffic: 600 (year 2021),  Truck Traffic: 18%,  Average Future Daily Traffic: 514 (year 2032),  Design Load: HS 20,  Features Intersected: UNNAMED STREAM,  Facility Carried by Structure: TR 5-HARMONY CH RO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.458,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1003168,  Location: 0.125 E. IL 37 (Lat: 37.862183,  Lng: -88.925469),  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 800 (year 2021),  Truck Traffic: 17%,  Average Future Daily Traffic: 914 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB TO POND CREEK,  Facility Carried by Structure: HARMONY CHURCH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.481,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 280003,  Location: .3 MI. S OF W. FRANK (Lat: 37.893167,  Lng: -88.945397),  Route carried "under" structure: Interstate 57,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 31,000 (year 2020),  Truck Traffic: 44%,  Features Intersected: FAI RTE 57,  Facility Carried by Structure: B N RR
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 103.510,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.4m (83.3ft)

Find on map >>   Show street view

Structure Number: 280039,  Location: IN WEST FRANKFORT (Lat: 37.897739,  Lng: -88.946175),  Route carried "under" structure: Interstate 57,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 40,000 (year 2021),  Truck Traffic: 39%,  Features Intersected: INTERSTATE 57,  Facility Carried by Structure: ILL 149
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 103.961,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 280058,  Location: 1.5 MI S OF FAP 873 (Lat: 37.875819,  Lng: -88.941250),  Route carried "under" structure: Interstate 57,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 31,000 (year 2020),  Truck Traffic: 44%,  Features Intersected: FAI RTE 57,  Facility Carried by Structure: FAU 9496
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 101.466,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.0m (75.5ft)

Find on map >>   Show street view

Structure Number: 280061,  Location: NEAR SCL W FRANKFORT (Lat: 37.891200,  Lng: -88.945011),  Route carried "under" structure: Interstate 57,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 31,000 (year 2020),  Truck Traffic: 44%,  Features Intersected: INTERSTATE 57,  Facility Carried by Structure: NORTH RD-W FRANKFO
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 103.253,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.4m (63.6ft)

Find on map >>   Show street view

Structure Number: 280062,  Location: 3.5 MI S BENTON (Lat: 37.950261,  Lng: -88.935536),  Route carried "under" structure: Interstate 57,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 40,000 (year 2021),  Truck Traffic: 39%,  Features Intersected: FAI 57,  Facility Carried by Structure: FAS 1877 (YELLOW B
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 110.012,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.4m (60.4ft)

Find on map >>   Show street view

Structure Number: 280079,  Location: AT NCL W. FRANKFORT (Lat: 37.908150,  Lng: -88.946419),  Route carried "under" structure: Other road ,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 550 (year 2019),  Truck Traffic: 8%,  Features Intersected: 7TH ST,  Facility Carried by Structure: INTERSTATE 57 NB
Minimum Vertical Clearance: 6.15m (20.18ft),  Kilometerpoint: 2.060,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 28008,  Location: AT NCL W. FRANKFORT (Lat: 37.908144,  Lng: -88.946247),  Route carried "under" structure: Other road ,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 550 (year 2019),  Truck Traffic: 8%,  Features Intersected: 7TH ST,  Facility Carried by Structure: INTERSTATE 57 SB
Minimum Vertical Clearance: 6.15m (20.18ft),  Kilometerpoint: 2.076,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Discuss West Frankfort, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.