Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Westchester, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 171ft / 52.1mTotal length
  • $12,733,000Total costs
  • 409,975Total average daily traffic
  • 29,208Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Westchester
  • No street view available for this location

New bridges in Westchester, IL - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 31930-1939
  • 41950-1959
  • 21960-1969
  • 42000-2009
Reconstructed bridges in Westchester, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Westchester, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Good
  • 50.0%Satisfactory
  • 25.0%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 37.5%Good
  • 12.5%Satisfactory
  • 25.0%Fair
  • 25.0%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 37.5%Good
  • 37.5%Satisfactory
  • 25.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 16.7%Very good
  • 16.7%Good
  • 33.3%Satisfactory
  • 16.7%Fair
  • 16.7%Poor
Find on map >>   Show street view

Structure Number: 160088,  Location: 0.5 M E US 45 (Lat: 41.870758,  Lng: -87.872908),  Route carried "on" structure: Interstate 290,  Year Built: 1952,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 140,700 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 201,262 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: ADDISON CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.032,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 37.9m (124.3ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.6m (41.3ft),  Curb-To-Curb Width: 37.9m (124.3ft),  Out-to-Out Width: 39.8m (130.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 160339,  Location: 0.1 M S CERMAK RD (Lat: 41.847717,  Lng: -87.880722),  Route carried "on" structure: US 12,  Year Built: 1958,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 4.43m (14.53ft),  Average Daily Traffic: 22,800 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 21,836 (year 2032),  Design Load: HS 20,  Features Intersected: SALT CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 91.811,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.3m (73.2ft),  Skew: 34 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.8m (48.6ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 22.3m (73.2ft),  Out-to-Out Width: 26.1m (85.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 85.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.42m (14.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $959,000,  Roadway Improvement Cost: $96,000,  Total Project Cost: $1,439,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 160962,  Location: 0.8 M E US 45 (Lat: 41.863661,  Lng: -87.868003),  Route carried "on" structure: Other road ,  Year Built: 1938,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 24.84m (81.50ft),  Average Daily Traffic: 25,000 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 25,647 (year 2032),  Features Intersected: RR - IHB & GARDNER,  Facility Carried by Structure: ROOSEVELT RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.329,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 13,  Length of Maximum Span: 23.5m (77.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 83.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 26.09m (85.60ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $7,529,000,  Roadway Improvement Cost: $753,000,  Total Project Cost: $11,294,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 162761,  Location: 3.7 M W IL 43 (Lat: 41.870433,  Lng: -87.877847),  Route carried "on" structure: Other road ,  Year Built: 2002,  Status: Open,  Structure Length: 6.92m (22.70ft),  Average Daily Traffic: 2,200 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,725 (year 2032),  Design Load: HS 20,  Features Intersected: I-290 IKE,  Facility Carried by Structure: WESTCHESTER BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.770,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 9.2m (30.2ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.0m (91.9ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 62.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 162789,  Location: 0.6 M E US 45 (Lat: 41.863558,  Lng: -87.871858),  Route carried "on" structure: Other road ,  Year Built: 2003,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 25,000 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 25,647 (year 2032),  Design Load: HS 20,  Features Intersected: ADDISON CREEK,  Facility Carried by Structure: ROOSEVELT RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.007,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb or Sidewalk Widths: Left: 7.0m (23.0ft),  Right: 7.0m (23.0ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 32.9m (107.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 163106,  Location: 0.2 M S ROOSEVELTP20 (Lat: 41.861353,  Lng: -87.867647),  Route carried "on" structure: Other road ,  Year Built: 1957,  Status: Open,  Structure Length: 6.89m (22.60ft),  Average Daily Traffic: 2,750 (year 2018),  Truck Traffic: 8%,  Average Future Daily Traffic: 2,350 (year 2032),  Design Load: HS 20,  Features Intersected: ADDISON CR,  Facility Carried by Structure: GARDNER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.428,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 163231,  Location: 0.5 MI E.OF US 45 (Lat: 41.870475,  Lng: -87.872436),  Route carried "on" structure: City street ,  Year Built: 1952,  Status: Open,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 500 (year 2018),  Truck Traffic: 8%,  Average Future Daily Traffic: 215 (year 2032),  Design Load: HS 20,  Features Intersected: ADDISON CREEK,  Facility Carried by Structure: WEDGEWOOD DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.274,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.5m (41.0ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Serious,  Superstructure: Serious,  Substructure: Fair,  Channel: Fair,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 168165,  Location: 0.5 MI E OF US 45 (Lat: 41.867217,  Lng: -87.871383),  Route carried "on" structure: City street ,  Year Built: 1930,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 475 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 215 (year 2032),  Features Intersected: ADDISON CR,  Facility Carried by Structure: GLADSTONE ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.467,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Serious,  Superstructure: Serious,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 21.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 160631,  Location: 0.8 M E US 45 (Lat: 41.850203,  Lng: -87.867122),  Route carried "under" structure: City street ,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 1,750 (year 2018),  Truck Traffic: 8%,  Features Intersected: RR - IHB & GARDNER,  Facility Carried by Structure: CERMAK RD (22ND ST
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 0.660,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.5m (90.2ft)

Find on map >>   Show street view

Structure Number: 160962,  Location: 0.8 M E US 45 (Lat: 41.860328,  Lng: -87.867600),  Route carried "under" structure: Other road ,  Year Built: 1938,  Structure Length: 0. m,  Average Daily Traffic: 2,750 (year 2018),  Truck Traffic: 8%,  Features Intersected: RR - IHB & GARDNER,  Facility Carried by Structure: ROOSEVELT RD
Minimum Vertical Clearance: 4.11m (13.48ft),  Kilometerpoint: 3.315,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 162019,  Location: 0.4 M E US 45 P20 (Lat: 41.863433,  Lng: -87.876053),  Route carried "under" structure: Other road ,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2021),  Truck Traffic: 4%,  Features Intersected: ROOSEVELT RD,  Facility Carried by Structure: CC RR
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 3.653,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 43.9m (144.0ft)

Find on map >>   Show street view

Structure Number: 162761,  Location: 3.7 M W IL 43 (Lat: 41.870272,  Lng: -87.877539),  Route carried "under" structure: Other road ,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 27,000 (year 2021),  Truck Traffic: 15%,  Features Intersected: I-290 IKE,  Facility Carried by Structure: WESTCHESTER BLVD
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 2.253,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 162761,  Location: 3.7 M W IL 43 (Lat: 41.870433,  Lng: -87.877847),  Route carried "under" structure: Interstate 290,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 131,300 (year 2021),  Truck Traffic: 6%,  Features Intersected: I-290 IKE,  Facility Carried by Structure: WESTCHESTER BLVD
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 28.613,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 163105,  Location: 0.15 S ROOSEVELT P2 (Lat: 41.859867,  Lng: -87.867581),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 2,750 (year 2018),  Truck Traffic: 8%,  Features Intersected: GARDNER RD,  Facility Carried by Structure: CC RR
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 3.267,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 18.0m (59.1ft)

Discuss Westchester, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.